Several techniques were used to improve 0.3~0.5 mm microvascular anastomosis. These included (1) non-isolation of adventitia, (2) modified two—point anastomosis, (3) clamping only the inflow in veins anastomosis, (4) atraumatic measurement of vascular patency, (5) post operative stimulation by electromagnetic fields, which accelerated the healing of the vessels. The chance of patency following anastomosis in experimental group was significantly much greater than that in the control one (plt;0.001). We have have also used these techniques in 11 patients with fingers replantion or smaller lymphatic anastomosis. All of the operations were successful.
This study aims to investigate the therapeutic efficacy of 50 Hz-0.6 mT low-frequency pulsed electromagnetic field (PEMF) on postmenopausal osteoporosis in ovariectomized rats. Thirty 3-month-old female SD rats were selected and divided into a sham operation group (Sham), an ovariectomized model group (OVX), and a low-frequency pulsed electromagnetic field (PEMF) treatment group, with 10 rats in each group. After 8 weeks, the whole-body bone mineral density (BMD) of each group of rats was measured. The treatment group began to receive PEMF stimulation for 90 minutes daily, while the OVX group only received a simulated placement without electricity. After 6 weeks of intervention, all rats were sacrificed and tested for in vitro BMD, micro-CT, biomechanics, serum biochemical indicators, and bone tissue-related proteins. The results showed that the BMD of the OVX group was significantly lower than that of the Sham group 8 weeks after surgery, indicating successful modeling. After 6 weeks of treatment, compared with the OVX group, the PEMF group exhibited significantly increased BMD in the whole body, femur, and vertebral bodies. Micro-CT analysis results showed improved bone microstructure, significantly increased maximum load and bending strength of the femur, elevated levels of serum bone formation markers, and increased expression of osteogenic-related proteins. In conclusion, this study demonstrates that daily 90-minute exposure to 50 Hz-0.6 mT PEMF effectively enhances BMD, improves bone biomechanical properties, optimizes bone microstructure, stimulates bone formation, and inhibits bone resorption in ovariectomized rats, highlighting its therapeutic potential for postmenopausal osteoporosis.
One of the main technical challenges when integrating magnetic resonance imaging (MRI) systems with medical linear accelerator is the strong interference of fringe magnetic fields from the MRI system with the electron beams of linear accelerator, making the linear accelerator not to work properly. In order to minimize the interference of magnetic fields, a magnetic shielding cylinder with an open structure made of high permeability materials is designed. ANSYS Maxwell was used to simulate Helmholtz coil which generate uniform magnetic field instead of the fringe magnetic fields which affect accelerator gun. The parameters of shielding tube, such as permeability, radius, length, side thickness, bottom thickness and fringe magnetic fields strength are simulated, and the data is processed by MATLAB to compare the shielding performance. This article gives out a list of magnetic shielding effectiveness with different side thickness and bottom thickness under the optimal radius and length, which showes that this design can meet the shielding requirement for the MRI-linear accelerator system.
The possible influence of electromagnetic field (EMF) on the function of neural systems has been widely concerned. In this article, we intend to investigate the effects of long term power frequency EMF exposure on brain cognitive functions and it’s mechanism. The Sprague-Dawley (SD) rats were randomly divided into 3 groups: the rats in EMF Ⅰ group were placed in the 2 mT power frequency EMF for 24 days. The rats in EMF Ⅱ group were placed in the 2 mT power frequency EMF for 48 days. The rats in control group were not exposed to the EMF. Then, the 16 channel local field potentials (LFPs) were recorded from rats’ prefrontal cortex (PFC) in each group during the working memory (WM) tasks. The causal networks of LFPs were also established by applying the directed transfer function (DTF). Based on that, the differences of behavior and the LFPs network connection patterns between different groups were compared in order to investigate the influence of long term power frequency EMF exposure on working memory. The results showed the rats in the EMF Ⅱ group needed more training to reach the task correction criterion (over 80%). Moreover, the causal network connection strength and the global efficiency of the rats in EMF Ⅰ and EMF Ⅱ groups were significantly lower than the corresponding values of the control group. Meanwhile, significant differences of causal density values were found between EMF Ⅱ group and the other two groups. These results indicate that long term exposure to 2 mT power frequency EMF will reduce the connection strength and the information transfer efficiency of the LFPs causal network in the PFC, as well as the behavior performance of the rats. These results may explain the effect of EMF exposure on working memory from the view of neural network connectivity and provide a support for further studies on the mechanism of the effect of EMF on cognition.
According to the coupling relationship of electromagnetic field and acoustic field when electromagnetic field irradiates low conductivity objects, we carried out a study on the magnetoacoustic effect and thermoacoustic effect in pulsed magnetic excitation. In this paper, we provide the pressure wave equation in pulsed magnetic excitation based on the theory of electromagnetic field and acoustic wave propagation. A 2-dimensional coil carrying current and a circular thin sheet model were constructed to simulate the physical imaging environment. The transient electromagnetic field was simulated using finite element method. Numerical studies were conducted to simulate the pressures excited by magnetoacoustic effect and thermoacoustic effect according to the result of electromagnetic simulation. It was shown that the thermoacoustic effect played a leading role in the low conductivity objects on the microsecond Gauss pulsed magnetic excitation, and thermoacoustic effect and magnetoacoustic effect coexisted on the microsecond Gauss pulsed magnetic field and 0.2 T static magnetic field excitation. This study lays the foundation for the further application of magnetoacoustic tomography with magnetic induction and magnetically mediated thermoacoustic imaging.
The present research is to investigate the time effect of sinusoidal electromagnetic fields (SEMFs) at different exposure time on the biomechanical properties in rats, and to find a best time for improving biomechanical properties. Forty female SD rats were randomly divided into five groups, i.e. control group, 45 min SEMFs group, 90 min SEMFs group, 180 min SEMFs group, and 270 min SEMFs group. In addition to the control group, other groups were exposed to 50 Hz and 0.1 mT magnetic field every day for the corresponding time periods. After eight weeks, bone mineral density (BMD), bone biomechanics, bone tissue morphology, micro-CT and pathological examination were performed. The results showed that there was no abnormal pathological finding in the experimental groups. In the 90 min SEMFs group, BMD, femur maximum load, elastic modulus, yield strength, trabecular number (Tb.N), trabecular thickness (Tb.Th) and trabecular area (Tb.Ar) percentage were all significantly higher than those in the control group (P<0.01), and trabecular separation (Tb.Sp) was significantly lower than that of the control group (P<0.01). However, for other experimental groups, some indices showed statistical significance compared to the control group (P<0.05), but some did not (P>0.05). This study showed that under 50 Hz and 0.1 mT SEMFs, 90 min is the best time that can effectively increase bone mineral density, improve the bone tissue microstructure organization and the biomechanical properties.
ObjectiveTo compare the clinical effects of pulsed electromagnetic fields (PEMFs) with oral alendronate in the treatment of postmenopausal osteoporosis. MethodsFourty patients diagnosed to have postmenopausal osteoporosis (OP) from September 2009 to September 2010 were included in our study. They were randomly divided into the experimental group and the control group. All patients were administered the same basic drugs:Caltrate 600 mg and Alfacalcidol 0.5 μg per day. For the experimental group, PEMFs were offered 6 times per week for 5 weeks (30 times in total), and patients in this group were followed up for 12 weeks. For the control group, alendronate was given at a dose of 70 mg per week for 12 weeks. Bone mineral density (BMD), visual analogue scale, and manual muscle testing (MMT) scale were evaluated before, 1 week, 5 weeks, and 12 weeks after intervention. ResultsIncreasing of BMD, pain relieving, and improvement of MMT had a trend of increasing values after 5 weeks of treatment in the experimental group (P<0.05), but there was no significant difference between the two groups (P>0.05). However, there was a significant difference between the two groups in patients' lower back muscle strength after treatment (P<0.05). ConclusionPEMFs have the same effect as alendronate in pain relief, and bone mass and muscle strength improvement, and are even advantageous in increasing back muscle strength compared with alendronate.
To observe the effect of pulsed electromagnetic fields (PEMFs) of different treatment time on bone mineral density of femur in ovariectomized rats, so as to find out the treatment time for the best therapeutic efficacy. Methods Fifty female SD rats were randomly divided into 5 groups: sham-ovariectomized (SHAM) group (no PEMFs treatment), ovariectomy (OVX) control group (no PEMFs treatment), OVX I, II and III groups (PEMFs treatment at 8 Hz frequency with 3. 8 ×10-10A/m intensity 20, 40, and 60 minutes daily for 30 days, respectively). All rats were given bilateral ovariectomy except those in the SHAM control group. Bone mineral density (BMD) of femur was assessed at 30 days after PEMFs treatment. Results In OVX control group, hypotrichosis, hypoactivity and l istlessness were observed after operation; and in SHAM group, OVX I group, OVX II group and OVX III group, pilus, psyche and activity were normal. The BMD values were (0.226 ± 0.011), (0.210 ± 0.011), (0.231 ± 0.013), (0.231 ± 0.017) and (0.229 ± 0.013) g/cm2 in SHAM group, OVX control group, OVX I group, OVX II group and OVX III group respectively, showing significant differences between OVX control group and other groups (P lt; 0.05), but showing no significant differences between other 4 groups (P gt; 0.05). Conclusion P EMFs of the three different treatment times can maintain the BMD in ovariectomized rats. It shows that PEMFs have the same effect of maintaining BMD with increasing of treatment time at the range of 20-60 minutes in ovariectomized rats.
In the present work, Monte Carlo simulations were employed to study the characteristics of the dose distribution of high energy electron beam in the presence of uniform transverse magnetic field. The simulations carried out the transport processes of the 30 MeV electron beam in the homogeneous water phantom with different magnetic field. It was found that the dose distribution of the 30 MeV electron beam had changed significantly because of the magnetic field. The result showed that the range of the electron beam was decreased obviously and it formed a very high dose peak at the end of the range, and the ratio of maximum dose to the dose of the surface was greatly increased. The results of this study demonstrated that we could change the depth dose distribution of electron beam which is analogous to the heavy ion by modulating the energy of the electron and magnetic field. It means that using magnetic fields in conjunction with electron radiation therapy has great application prospect, but it also has brought new challenges for the research of dose algorithm.
The gradient field, one of the core magnetic fields in magnetic resonance imaging (MRI) systems, is generated by gradient coils and plays a critical role in spatial encoding and the generation of echo signals. The uniformity or linearity of the gradient field directly impacts the quality and distortion level of MRI images. However, traditional point measurement methods lack accuracy in assessing the linearity of gradient fields, making it difficult to provide effective parameters for image distortion correction. This paper introduced a spherical measurement-based method that involved measuring the magnetic field distribution on a sphere, followed by detailed magnetic field calculations and linearity analysis. This study, applied to assess the nonlinearity of asymmetric head gradient coils, demonstrated more comprehensive and precise results compared to point measurement methods. This advancement not only strengthens the scientific basis for the design of gradient coils but also provides more reliable parameters and methods for the accurate correction of MRI image distortions.