Objective To prepare collagen-chitosan /nano-hydroxyapatite-collagen-polylactic acid (Col-CS/ nHAC-PLA) biomimetic scaffold and to examine its biocompatibility so as to lay the foundation for its application on the treatment of osteochondral defect. Methods PLA was dissolved in dioxane for getting final concentration of 8%, and the nHAC power was added at a weight ratio of nHAC to PLA, 1 ∶ 1. The solution was poured into a mold and frozen. CS and Col were dissolved in 2% acetum for getting the final concentrations of 2% and 1% respectively, then compounded at a weight ratio of CS to Col, 20 ∶ 1. The solution was poured into the frozen mold containing nHAC-PLA, and then biomimetic osteochondral scaffold of Col-CS/nHAC-PLA was prepared by freeze-drying. Acute systemic toxicity test, intracutaneous stimulation test, pyrogen test, hemolysis test, cytotoxicity test, and bone implant test were performed to evaluate its biocompatibility. Results Col-CS/nHAC-PLA had no acute systemic toxicity. Primary irritation index was 0, indicating that Col-CS/nHAC-PLA had very slight skin irritation. In pyrogen test, the increasing temperature of each rabbit was less than 0.6℃, and the increasing temperature sum of 3 rabbits was less than 1.3℃, which was consistent with the evaluation criteria. Hemolytic rate of Col-CS/nHAC-PLA was 1.38% (far less than 5%). The toxicity grade of Col-CS/nHAC-PLA was classified as grade I. Bone implant test showed that Col-CS/nHAC-PLA had good biocompatibility with the surrounding tissue. Conclusion Col-CS/ nHAC-PLA scaffold has good biocompatibility, which can be used as an alternative osteochondral scaffold.
Objective Titania and Ag containing nano-hydroxyapatite/polyamide 66 (TiO2-Ag-nHA/PA66) composite bone fill ing material has good biocompatibil ity and biological safety. To investigate the antibacterial effect and Ag+ release characteristics of TiO2-Ag-nHA/PA66 composite bone fill ing material containing different concentrations of Ag+ in vitro. Methods The n-HA/PA66 composite bone fill ing material A1 (material A1) was prepared by co-polymerization method, and TiO2-Ag-nHA/PA66 composite bone fill ing materials A2 and A3 (materials A2 and A3) were prepared by thesame way containing Ag+ of 0.22wt% and 0.64wt%, respectively, and the TiO2 content was 2.35wt%. The materials A2 and A3 were respectively immersed in 50 mL simulated body fluid (SBF), and Ag+ concentration was measured by atomic absorption spectrometry at 1, 3, 7, 14, 21, and 49 days. The inhibition ring test and colony count method were used to evaluate antibiotic effect against Staphylococcus aureus and Escherichia coli, the anti-adhesion capacity of Staphylococcus aureus and Escherichia coli was observed by scanning electron microscope (SEM). Results There was no significant difference in the Ag+ concentration between materials A2 and A3 at 1 day and 3 days (P gt; 0.05); and there were significant differences in the Ag+ concentration between materials A2 and A3 after 7 days (P lt; 0.05). The inhibition ring diameters of materials A2 and A3 to Staphylococcus aureus and Escherichia coli reached the maximum at 1 day, which were (13.40 ± 2.88), (9.40 ± 1.14) mm and (23.60 ± 1.14), (18.80 ± 0.84) mm, showing significant difference (P lt; 0.05) between materials A2 and A3 respectively; and then, the diameter of inhibition ring reduced with the time. The antibacterial effect of materials A2 and A3 against Staphylococcus aureus and Escherichia coli lasted 15, 33 days and 9, 24 days, respectively. No inhibition ring was observed around material A1 all the time. And the inhibitory rates of materials A2 and A3 were 89.74% ± 3.62%, 94.18% ± 2.05% and 78.65% ± 5.64%, 85.96% ± 2.50%; showing significant differences (P lt; 0.05) among materials A1, A2, and A3. SEM showed that bacterial adhesion of materials A2 and A3 was obviously fewer than that of material A1. Conclusion TiO2-Ag-nHA/PA66 composite bone fill ing material has antibacterial property against Staphylococcus aureus and Escherichia coli, and it has a good release effect in SBF.
ObjectiveTo evaluate the effect of poly-amino acid/nano-hydroxyapatite/calcium sulfate (PHC) Cage in lumbar interbody fusion of the goat. MethodsEighteen mature female goats (weighing 29-33 kg) were divided into 3 groups randomly: PHC Cage group (group A), titanium Cage group (group B), and ilium group (group C). A left extraperitoneal approach was used to establish the animal model of discectomy and interbody fusion with Cage or ilium. The general situation was observed for 24 weeks after operation. X-ray films were taken to measure disc space height (DSH) before operation and at 4, 12, and 24 weeks after operation. CT three dimensional reconstuction was performed at 24 weeks after operation to evaluate the interbody fusion according to modified Brantigan grading. The specimens of L3, 4 were harvested for mechanical test, histological, and scanning electron microscope (SEM) observation at 24 weeks after operation. ResultsAll goats survived to the end of experiment. DSH at 4 weeks after operation increased when compared with preoperative one in each group, and then decreased;DSH was significantly lower at 12 and 24 weeks after operation than preoperative one in group C (P<0.05). There was no significant difference in DSH among 3 groups at preoperation and 4 weeks after operation (P>0.05);at 12 and 24 weeks after operation, DSH of groups A and B was significantly higher than that of group C (P<0.05), but no significant difference was found between groups A and B (P>0.05). CT three dimensional reconstuction showed that bony fusion was obtained in all goats of groups A and C, and in 3 goats of group B;according to modified Brantigan grading, the scores of groups A and C were significantlly higher than that of group B (P<0.05), but no significant difference between groups A and C (P>0.05). The biomechanical test showed that there was no significant difference in range of motion between group A and group B (P>0.05), which were significantly lower than that of group C (P<0.05). Microscopy and SEM observations showed that the interface between the Cage and vertebral body in group A was compact without obvious gap, and most conjunctive region was filled with osseous tissue;the interface was filled with soft tissue, and the connection was slack with obvious gap in some region in group B;the interface connection was compact, most region was filled with osseous tissue in group C. ConclusionThe interbody fusion with PHC Cage is effective in goat lumbar interbody fusion model. The interface connection is compact between the Cage and the host bone followed by micro-degradation of PHC Cage, but the long-term degradation need further observation.
ObjectiveTo discuss the early effectiveness of polyaminoacid/nano-hydroxyapatite/calcium sulfate (PAA/HA/CS) Cage (PHC Cage) in lumbar fusion surgery. MethodsThirty cases undergoing lumbar fusion of single segment between March and September 2014 were enrolled in this study. The patients were randomly divided into the trial group (n=20) and the control group (n=10). The PHC Cage was implanted in the trial group, while the polyetheretherketone (PEEK) Cage was implanted in the control group. The patients of 2 groups mainly presented lumbocrural pain and lower limb radiation pain or numbness. There was no significant difference in gender, age, type, affected segment, disease duration, preoperative intervertebral height, the lordosis angle of fusion segments, and the Oswestry Disability Index (ODI) between 2 groups (P > 0.05). Lateral lumbar X-ray films and three dimensional CT were taken preoperatively and at 1 week and 3, 6, and 12 months postoperatively. The intervertebral height and the lordosis angle of fusion segments at 1 week and 3, 6, and 12 months after operation and ODI at 3, 6, and 12 months after operation were measured; and the bone graft fusion rate was evaluated according to Brantigan criteria. ResultsThere was no significant difference in operation time, intraoperative blood loss, and the amount of autologous blood transfusion between 2 groups (P > 0.05). Healing by first intention was obtained in 30 cases. All patients were followed up 12 months. The intervertebral height of fusion segments, the lordosis angle of fusion segments, and ODI at each time point after operation were significantly improved when compared with preoperative ones (P < 0.05). The ODI showed significant difference between 3 months and 6, 12 months (P < 0.05), but there was no significant difference between the other time points after operation (P > 0.05). There was no significant difference in the intervertebral height and the lordosis angle of fusion segments between groups at different time points (P > 0.05). There was no significant difference in the above indexes between the trial group and the control group at each time point (P > 0.05). At last follow-up, 5 cases were rated as Brantigan grade E, 13 cases as grade D, and 2 cases as grade C in the trial group; 4 cases were rated grade E, 5 cases as grade D, and 1 case as grade C in the control group. The bone fusion rate was 90% in 2 groups. ConclusionThe PHC Cage can effectively restore and maintain the disc height of fusion segment, normal sequence and biomechanical stability of the lumbar spine. The PHC Cage is similar to the PEEK Cage and has good clinical outcome in short-term follow-up.
ObjectiveTo explore the effectiveness of nano-hydroxyapatite/polyamide-66 (n-HA/PA66) Cage in interbody fusion for degenerative lumbar scoliosis.MethodsA retrospective analysis was designed and conducted for 43 patients, who underwent posterior decompression and n-HA/PA66 Cage interbody fusion with correction of deformity between January 2013 and June 2016. Eighteen cases were single-level fusion (single-level group) and 25 cases were double-level fusion (double-level group). There was no significant difference in gender, age, body mass index, direction of convex, degree of apical rotation, fusion level, the number of osteoporotic patients, pre-operative intervertebral height of fusion segments, coronal Cobb angle, visual analogue score (VAS), and modified Oswestry Disability Index (ODI) between 2 groups (P>0.05). The operation time, intraoperative blood loss, postoperative drainage, hospital stay, and complications of the operation were recorded. Modified ODI, VAS score, and MacNab criteria were adopted to assess clinical outcomes. Radiographic indexes, including intervertebral height of fusion segments, coronal Cobb angle, disc insertion depth, and the bone graft fusion rate, were also evaluated.ResultsThere was no significant difference in operation time, intraoperative blood loss, postoperative drainage, and hospital stay between 2 groups (P>0.05). All patients were followed up 18-62 months (mean, 30.9 months). Wound complications, postoperative delirium, and Cage retropulsion occurred in 4 cases (2 cases in single-level group, 2 cases in double-level group), 1 case of single-level group, and 1 case of double-level group, respectively. The intervertebral height of fusion segments after operation significantly improved compared with preoperative ones in both groups (P<0.05). At last follow-up, the intervertebral height in double-level group was superior to which in single-level group (P<0.05). The coronal Cobb angles after operation significantly improved compared with preoperative ones (P<0.05), and no significant difference was found between 2 groups at each time point (P>0.05). The disc insertion depth showed no significant difference between different time points after operation in 2 groups (P>0.05) and between 2 groups at each time point after operation (P>0.05). Bony fusion was obtained in all patients at last follow-up. The VAS score and modified ODI after operation in both groups were superior to those before operation (P<0.05). The VAS score in double-level group was higher than that in single-level group (P<0.05) at last follow-up, and no significant difference was found in VAS score and modified ODI between 2 groups at other time points (P>0.05). According to the MacNab criteria, the excellent and good rates at last follow-up were 94.4% and 84.0% in single-level group and double-level group, respectively.ConclusionThe n-HA/PA66 Cage can effectively restore and maintain the disc height of fusion segment, normal sequence, and biomechanical stability of the spine, and gain favorable effectivenss for degenerative lumbar scoliosis. And double-level fusion is superior to single-level fusion in maintaining disc height of fusion segment.