find Keyword "otal knee arthroplasty" 164 results
  • SHORT-TERM EFFECT OF ROTATING HINGE KNEE PROSTHESIS

    Objective To discuss shortterm effect of rotating hinge knee prosthesis. Methods From July 2002 to April 2005, 17 cases of severe knee joint deformity and instability received rotating hinge knee prosthesis for total knee arthroplasty. There were 8 males and 9 females, aging from 41 to 79 years. The left joints were involved in 10 cases and right joint in 7 cases. All patients were admitted because of pain. The course of disease was from 1 to 7 years. There were 10 cases of osteoarthritis,5 cases of rheumatoid arthritis,1 case of traumatic arthritis after operation of left femur fracture,and 1 case of traumatic arthritis with injury of anterior cruciate ligament, meniscus medialis and medial collateral ligament after operation of left fracture of tibial plateau. According to HSS(hospital for special surgery) scoring system,the preoperative score was 36 to 58 with an average of 48.6. The preoperative flexed motion range of articulation was 21° to 80° with an average of 57.4°. Results All patients were followed up from 7 months to 3 years with an average of 23.6 months. There were no complications of thrombogenesis of veins of lower extremity, pulmonary embolism, palsy of peroneal nerve, fracture, and breakage of extended knee structure. Infection occurred in 1 case at 3 months postoperatively,the prosthesis was dislodged,antibiotic-impregnated cement was filed with knee joint,twostage arthroplasty was expected. At the last follow-up,the HSS score was 78 to 98 with an average of 91.1 in 16 patients. The flexed motion range of articulation was 75° to 100° with an average of 852° at 2 weeks postoperatively. The flexed motionrange of articular was 85° to 123° with an average of 1083° at the last followup. There were significant differences in HSS score and motion range of articular between preoperation and thelast follow-up (P<0.05). Conclusion The short-term outcome of rotating hinge knee prosthesis is good and a long term followup is necessary.

    Release date:2016-09-01 09:22 Export PDF Favorites Scan
  • MID-TERM THERAPEUTIC EFFECT ANALYSIS OF CEMENTLESS TOTAL KNEE ARTHROPLASTY WITHOUTPATELLA REPLACEMENT

    【Abstract】 Objective To explore the flexibil ity and rel iabil ity of cementless total knee arthroplasty (TKA) without patellareplacement through a retrospective study of the mid-term therapeutic effect of the treatment of the patients. Methods FromJune 1997 to March 2000, a consecutive series of 152 (152 knees) cementless TKA performed in Hessing-Stiftung was studied. Among them, there were 63 males and 89 females, with 70 left knees and 82 right knees. Their ages ranged from 51 years to 72 years, with an average of 59 years. There were 146 cases of osteoarthritis and 6 cases of traumatic arthritis. The course of the disease lasted for 1.0 years to 3.5 years. The EFK prostheses of German Plus company were used in all the cases. The HSS score before the operation was 41.5 ± 12.3, and the average range of motion was 55º (ranging from 30º to 90º). Results Five patients underwent anterior knee pain, and the pain was released after the appropriate treatment. No deep infection happened in all cases. A total of 145 patients (145 knees) were followed up for 5 years to 8 years. The HSS score was 87.5 ± 8.2 at the end of the follow-up, showing significant difference (P lt; 0.05). The average range of motion was 95º (ranging from 90º to 110º). Partial radiolucencies occurred at the tibia side in 18knees 3 to 6 months after the operation. Among them, the width was less than 2 mm in 15 knees without symptom, and more than 2 mm in 3 knees. There were 2 of the 3 knees which were revised at the tibia side because of the aseptic loosing, while 1 patient had only mild pain in the knee during the follow-up, with no sign of loosing. Conclusion The mid-term effect of cementless TKA is satisfactory. The ingrowth of femur and tibial bones is rel iable. The early stage migration of the component is the main reason of loosing. Satisfying outcomes can also be achieved without patella replacement during TKA.

    Release date:2016-09-01 09:12 Export PDF Favorites Scan
  • INFLUENCE OF POSTERIOR CONDYLAR OFFSET AND ANTEROPOSTERIOR FEMOROTIBIAL TRANSLATION ON KNEEFLEXION AFTER POSTERIOR CRUCIATE-SACRIFICING SELF ALIGNMENT BEARING TOTAL KNEE ARTHROPLASTY

    Objective To observe the posterior condylar offset (PCO) changes and anteroposterior femorotibial translation, to investigate the influence of them on the maximum knee range of flexion (ROF) in patients with posterior cruciatesacrificingself al ignment bearing total knee arthroplasty (TKA). Methods The cl inical data were analyzed retrospectively from 40 patients (40 knees) undergoing primary unilateral TC-PLUSTM SB posterior cruciate-sacrificing self al ignment andbearing TKA for osteoarthritis between January 2007 and June 2009. There were 18 males and 22 females with an average age of 70.6 years (range, 56-87 years). The disease duration was 5-14 years (mean, 9.1 years). The locations were the left side in 11 cases and the right side in 29 cases. Preoperative knee society score (KSS) and ROF were 48.0 ± 5.5 and (77.9 ± 9.0)°, respectively. The X-ray films were taken to measure PCO and anteroposterior femorotibial translation. Multi ple regression analysis was performed based on both the anteroposterior femorotibial translation and PCO changes as the independent variable, and maximum knee flexion as the dependent variable. Results All incisions healed by first intention. The patients were followed up 12-19 months (mean, 14.7 months). At last follow-up, there were significant differences in the KSS (91.9 ± 3.7, t=— 77.600, P=0.000), the ROF [(102.0 ± 9.3)°, t=— 23.105, P=0.000] when compared with preoperative values. Significant difference was observed in PCO (t=3.565, P=0.001) between before operation [(31.6 ± 5.5) mm] and at last follow-up [(30.6 ± 5.9) mm]. At ast follow-up, the anteroposterior femorotibial translation was (— 1.2 ± 2.1) mm (95%CI: — 1.9 mm to — 0.6 mm); femoral roll forward occurred in 27 cases (67.5%), no roll in 1 case (2.5%), and femoral roll back in 12 cases (30.0%). By multiple regression analysis (Stepwise method), the regression equation was establ ished (R=0.785, R2=0.617, F=61.128, P=0.000). Anteroposterior femorotibial translation could be introducted into the equation (t=7.818, P=0.000), but PCO changes were removed from the equation (t=1.471, P=0.150). Regression equation was y=25.587+2.349x. Conclusion Kinematics after TC-PLUSTM SB posterior cruciate-sacrificing self al ignment bearing TKA with posterior cruciate l igament-sacrificing show mostly roll forwardof the femur relative to the tibia, which have a negative effect on postoperative range of motion. There is no correlation between PCO changes and postoperative change in ROF in TC-PLUSTM SB posterior cruciate-sacrificing self al ignment bearing TKA.

    Release date:2016-08-31 05:41 Export PDF Favorites Scan
  • The application of enhanced recovery after surgery in pain management after total knee arthroplasty

    Objective To explore the application of enhanced recovery after surgery (ERAS) in pain management after knee arthroplasty (TKA). Methods Doctor-nurse pain management team was established based on ERAS between June and July 2016, and the pain management was carried out after training the doctors and nurses. According to the formula of two-sample mean comparison and inclusion and exclusion criteria, 60 TKA patients admitted to the hospital from March to May 2016 were assigned into the control group (before intervention) and 60 TKA patients admitted from August to October 2016 were assigned into the trial group (after intervention). The patients in the control group received routine pain management. In the trial group, preventive analgesia was performed, pain health education paths were built and ISBAR communication mode was made preoperatively; anesthesia protocols were optimized intraoperatively; multimodal analgesia based on time-demand was used postoperatively; continuing analgesia program was provided at the discharge. The pain score, Hospital for Special Surgery (HSS) knee score, average length of stay (ALOS) and average hospitalization cost (excluding materials) were compared between the two groups. Results The pain scores between the two groups at the admission and 6 hours after surgery were not statistically different (P>0.05), and the pain scores in the trial group 24, 48, 72 hours after surgery were significantly lower than those in the control group (P<0.05). The HSS scores between the two groups at the admission were not statistically different (P>0.05), and the HSS scores in the trial group 3 days, 1 week, and 1 month after surgery were significantly higher than those in the control group (P<0.05). And ALOS and average hospitalization cost (excluding materials) in the trial group were significantly lower than those in the control group (P<0.05). Conclusion The application of ERAS in pain management after TKA can effectively alleviate the postoperative pain, improve the patients’ knee function, shorten the ALOS, and decrease the average hospitalization cost.

    Release date:2017-09-22 03:44 Export PDF Favorites Scan
  • EFFECTIVENESS OF UC ULTRA-CONGRUENT ROTATING PLATFORM PROSTHESIS IN TREATMENT OF KNEE OSTEOARTHRITIS

    ObjectiveTo explore the effectiveness of UC ultra-congruent rotating platform prosthesis in the treatment of knee osteoarthritis by comparing with fixed-bearing implant. MethodsThe clinical data were retrospectively analyzed, from 98 patients (98 knees) with knee osteoarthritis undergoing primary total knee arthroplasty between January 2011 and December 2012. The UC ultra-congruent rotating platform prosthesis was used in 56 cases (mobile-bearing group) and fixed-bearing implant was used in 42 cases (fixed-bearing group). There was no significant difference in gender, age, side, weight, disease duration, grading of arthritis, the number of varus and valgus malformation, preoperative range of motion of the knee, the Knee Society Score (KSS) score, the visual analogue scale (VAS) score, femorotibial angle, tibial angle, and articular surface angle between 2 groups (P>0.05). The operation time (including anesthetic time), intraoperative blood loss, hospitalization time, total hospitalization expenses, postoperative range of motion of the knee, the KSS score, and the VAS score were compared. The femorotibial angle, tibial angle, and articular surface angle were measured on the basis of anteroposterior and lateral X-ray films, and prosthesis loosening was observed. ResultsThere was no significant difference in the operation time, intraoperative blood loss, and hospitalization time between 2 groups (P>0.05), while the total hospitalization expenses of fixed-bearing group were significantly lower than those of the mobile-bearing group (t=8.506, P=0.000). The patients were followed up 16-30 months in the mobile-bearing group, and for 16-38 months in the fixed-bearing group. Postoperative complications occurred in 3 cases (7.14%) of the fixed-bearing group (1 case of fat liquefaction of incision, 1 case of joint stiff, and 1 case of anterior knee pain), and in 3 cases (5.36%) of the mobile-bearing group (1 case of delayed wound healing, and 2 cases of anterior knee pain); there was no significant difference in the complication rate between 2 groups (χ2=0.133, P=0.516). At last follow-up, the KSS score, VAS score, range of motion of the knee, femorotibial angle, tibial angle, and articular surface angle were superior significantly to those before operation in both groups (P<0.05), but no significant difference was found between 2 groups (P>0.05). No radiographic signs of radiolucent line, prosthetic dislocation, patellar dislocation, prosthetic loosening, and fracture was found. ConclusionUC ultra-congruent rotating platform prosthesis in the treatment of knee osteoarthritis can effectively improve the knee joint function and relief pain, which has the same short-term effectiveness to fixed-bearing implant.

    Release date: Export PDF Favorites Scan
  • CLINICAL COMPARATIVE STUDIES ON EFFECT OF TRANEXAMIC ACID ON BLOOD LOSS ASSOCIATED WITH TOTAL KNEE ARTHROPLASTY

    To investigate an effect of tranexamic acid on blood loss associated with total knee arthroplasty (TKA).Methods From June 2005 to June 2006, 102 patients (43 males, 59 females; aged 59-77 years, averaged 68 years) underwent TKA. Of the 102 patients, 59 had osteoarthritis, 23 had rheumatoid arthritis, and 20 had traumatic arthritis.The illness course ranged from 2 to 12 years. They were randomized divided into Group A and Group B of 51 patients each. The patients in Group A received tranexamic acid, and the patients in Group B received an equal volume of normal saline. In Group A, 1 g of tranexamic acid dissolved in 250 ml of normal saline was intravenously infused before deflation of the tourniquet; another intravenous administration of the same drug of the same dosage was given 3 hours later. In Group B, only 250 ml of normal saline was infused intravenously. The amounts of blood loss and blood transfusion during operation and after operation in all the 102 patients were recorded. They were also observed for whether they had deep vein thrombosis. D-dimeride, fibrinogen, prothrombin time, and activated partial thromboplastin time were also examined before operation, during operation (deflation of the tourniquet), and 3 hours after operation.Results The blood loss was 256±149 ml in Group A and 306±214 ml in Group B during operation; there was no significant difference between the two groups(P>0.05). The postoperative drainage volume was 478±172 ml in Group A and 814±156 ml in Group B, and the total blood loss was 559±159 ml in Group A and 1.208±243 ml in Group B; there were significant differences between the two groups (P<0.05). The averaged amount of blood transfusion was 556±174 ml in Group A and 1 024± 278 ml in Group B; there was a significant difference between the two groups (P<0.05). The postoperative hemoglobin concentration was higher in GroupA than that in Group B (1.0-1.1 g/dL vs. 0.6-0.8 g/dL). The ostoperative follow-up for 612 months revealed that no deep vein thrombosis was found in both lower limbs of the patients by the color Doppler ultrasonography. The level of D-dimeride was significantly higher 3 hours after operation than before operation (0.92±0.56 mg/L vs. 0.35±0.13 mg/L in Group A; 1.32±0.79 mg/L vs. 0.37± 0.21 mg/L in Group B) (P<0.05). The D-dimeride level 3 hours after operation was significantly higher n Group B than in Group A(P<0.05). There were no significant differencesin the levels of fibrinogen, prothrombin time, and activated partial thromboplastin time between the two groups(P>0.05).Conclusion During and after the TKA operation, a shortterm use of tranexamic acid can significantly decrease blood loss and blood transfusion with no increasing risk for venous thrombosis.

    Release date:2016-09-01 09:22 Export PDF Favorites Scan
  • Research progress of failure and revision of unicompartmental knee arthroplasty

    Objective To conclude the failure factors of unicompartmental knee arthroplasty (UKA), and summarize the research progress of revision surgery. MethodsThe literature on UKA at home and abroad in recent years was reviewed to summarize its risk factors, treatment methods, including the evaluation of bone loss, prosthesis selection, and surgical techniques. ResultsThe factors inducing UKA failure mainly include improper indications, technical errors, and others. The application of digital orthopedic technology can reduce failures caused by surgical technical errors and shorten the learning curve. There are a variety of options for revision surgery after UKA failure, including polyethylene liner replacement, revision with UKA or total knee arthroplasty, with adequate preoperative evaluation prior to implementation. The biggest challenge in revision surgery is the management and reconstruction of bone defects. ConclusionThere is a risk of failure in UKA, which needs to be treated with caution and should be determined according to the type of failure.

    Release date:2023-02-13 09:57 Export PDF Favorites Scan
  • Biomechanical research on effects of pseudo-patella baja on stress of patellofemoral joint after total knee arthroplasty

    ObjectiveTo investigate biomechanical effects of pseudo-patella baja on stress of patellofemoral joint after total knee arthroplasty (TKA) by using finite element analysis (FEA).MethodsA series of CT and MRI of the left knee joint of two healthy volunteers and three-dimensional (3D) scanned data of TKA prosthesis were taken, and the 3D models of knee before and after TKA were established. The finite element model of pseudo-patella baja, normal patella, and alta patella after TKA were constructed by Insall-Salvafi (IS) ratio and Blackburne-Peel (BP) ratio. The load was applied along the direction of quadriceps femoris. After testing the validity of the finite element model, the high contact stress of patellofemoral joint was measured on the von Mise stress nephogram of pseudo-patella baja, normal patella, and alta patella after TKA when the knee flexion was 30°, 60°, and 90°. The average contact area was calculated according to two volunteers’ data.ResultsOn the finite element model of the normal patella after TKA with knee flexion 30°, 475 N pressure was applied along the direction of quadriceps femoris. The contact stress of patellofemoral joint was (1.29±0.41) MPa, which was similar to the results reported previously. The finite element model was valid. The von Mise stress nephogram showed that the stress mainly focused on the medial patellofemoral articular surface during knee flexion, and the contact point gradually moved up with the knee flexion deepened. The stress on the medial and lateral patellofemoral articular surface increased with the knee flexion deepened but decreased with the increase of patellar height. The effects of patellar height and knee flexion on the high contact stress of patellofemoral joint were similar among the finite element models after TKA based on the data of two volunteers. The high contact stress of patellofemoral joint increased with the knee flexion deepened in the same patellar height models (P<0.05), but decreased with the increase of patellar height in the same knee flexion models (P<0.05). The high contact stress of patellofemoral joint of pseudo-patella baja model was significantly higher than normal and alta patella models (P<0.05). The average contact area of patellofemoral joint of pseudo-patella baja was bigger than normal and alta patella models with the knee flexion deepened.ConclusionThe pseudo-patella baja after TKA has an important effect on the biomechanics of patellofemoral joint. Reserving the joint line and avoiding the occurrence of pseudo-patella baja can decrease the risk of anterior knee pain, patellar arthritis, and other complications caused by the increasing of contact stress of patellofemoral joint.

    Release date:2021-07-29 05:02 Export PDF Favorites Scan
  • RESEARCH PROGRESS OF DIFFERENCE BETWEEN HIGH-FLEXION PROSTHESIS AND CONVENTIONAL PROSTHESIS IN TOTAL KNEE ARTHROPLASTY

    ObjectiveTo summarize the research progress of the difference between high-flexion prosthesis and conventional prosthesis in total knee arthroplasty, so as to offer a reference for clinical choice of prosthesis. MethodsThe relevant literature on high-flexion prosthesis and conventional prosthesis in recent years was extensively reviewed and analyzed. ResultsThere are some controversies in range of motion and complications between high-flexion prosthesis and conventional prosthesis; while no obvious difference is found in knee function and satisfaction. ConclusionComprehensive evaluation should be considered when high-flexion prosthesis is selected; and the effectiveness needs further follow-up.

    Release date: Export PDF Favorites Scan
  • ANALYSIS OF SHORT-TERM RESULTS OF POST TOTAL KNEE ARTHROPLASTY USING TC-DYNAMIC POSTERIOR STABILIZED PROSTHESIS

    Objective To assess the feasibility, safety, and validity of the TC-Dynamic posterior stabilized prosthesis implanted in the total knee arthroplasty (TKA). Methods Twelve knees of 10 patients (the TC-Dynamic group) were followed up, who had been implanted with the TC-Dynamic posterior stabilized prosthesis from September 2003 to March 2004. Preoperative KSS knee scores were 16.08±11.58, function scores 13.75±19.79, and the range of motion (ROM) of the knee 75.00±26.46°. Meanwhile, 50 knees of 30 patients (the Scorpio group) werefollowed up, who had undergone TKA with the Scorpio posterior stabilized prosthesis.Preoperative KSS knee scores were 19.48±967, function scores 3.16±19.82,andthe ROM of the knee 80.80±22.82°. The anteroposterior and lateral X-ray filmsof each knee were examined before and after operation. The statistical Z-test was used to analyze the differences between the 2 groups in the improvement of the KSS knee scores, function scores, and ROM after operation. Results The average of the 130 days’ follow-up revealed that the patients implanted with the TC-Dynamic prosthesis had an excellent result. In the TC-Dynamic group, the KSS knee scores were 88.83±4.04 with improved scores of 72.75±14.47 compared with those before operation; function scores were 79.17±5.15 with improved scores of 65.42±19.47; the ROM of the knee was 107.92±11.57° with increased degrees of 32.92±32.22°.Meanwhile, in the Scorpio group, the KSS knee scores were 85.68±7.36 with improved scores of 66.20±10.44 compared with those before operation; function scores were 71.40±12.70 with improved scores of 68.24±25.35; the ROM of the knee was 109.20±11.13° withincreaseddegrees of 28.40±26.41°.There was no significant difference in the improvement of the KSS knee scores, function scores, and ROM after operation between the 2 groups (Pgt;0.01). All the X-ray films of the knees implanted with both the Scorpio prosthesis and the TC-Dynamic prosthesis were analyzed.No malalignment or lucent line with the prosthesis was seen in all these X-ray films. Conclusion The short-term follow-up indicates that the patients implanted with the TC-Dynamic prosthesis have an excellent result. The TC-Dynamic prosthesis with a scientific and proper design is more suitable for the Chinese. However, the long-term outcome of the patients implanted with the TC-Dynamic prosthesis should be observed in a larger number of TKA operations. The basic surgical principles, including excision of both the cruciate ligaments and correction of thebone deformity with the proper balancing of the soft tissues in flexion and extension, are still crucial to successful TKA and to the longterm high survivalrate of the knee prosthesis.

    Release date:2016-09-01 09:26 Export PDF Favorites Scan