west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "perforation" 117 results
  • Comparison of axial length measurement by Lenstar and contact A-scan in patients with idiopathic macular hole

    Objective To compare the axial length (AL) measured by Lenstar and contact AScan in the patients with idiopathic macular hole and study the correlation between the difference of the two measurements and the foveal thickness measured by optical coherence tomography (OCT). Methods Twenty-seven eyes of 26 idiopathic macular hole patients (IMH group) and 27 eyes of 25 patients with mild cataract (control group) were enrolled in this study. Foveal thickness was measured with 3D OCT. The AL was measured by Lenstar and contact A-Scan, and the consistency of the two measurements was determined by Bland-Altman analysis. The correlation between the difference of the two measurements and foveal thickness was analyzed by Pearson correlation analysis. Results Mean foveal thickness of IMH and control eyes were (372.85±60.02) μm and (243.44±22.50) μm, respectively. The difference between the foveal thickness of the two groups was highly significant (t=-10.490,P<0.001). In the IMH group, the AL measured by Lenstar and contact A-Scan were (23.20±1.12) mm and (23.18±1.13) mm, respectively, the difference between the two measurements was not statistically significant (t=-0.549,P=0.588), whereas in the control group, the AL was (23.41±0.72) mm by Lenstar and (23.33±0.74) mm by contact A-Scan, the two measurements were significantly different (t=-4.832,P<0.001). However, no correlation was found by Pearson correlation analysis between the difference of the two measurements and the foveal thickness in either IMH or control group (r=0.181,-0.141;P>0.05). ConclusionsAlthough there is no difference of axial length measurements using Lenstar and contact A-Scan in IMH eyes, in clinical measurements the results of two instruments should be taken into comprehensive consideration.

    Release date:2016-09-02 05:22 Export PDF Favorites Scan
  • APPLICATION OF DOPPLER IN THE SKIN FLAP OF VASTUS LATERALIS

    Objective To investigate a method of improving design of the skin flap pedicled with descending branch of lateral femoral circumflex artery, in order to increase the accuracy of preoperative Doppler location. Methods Firstly, the interspace between rectus femoris and vastus lateralis was regarded as line A, and the point of intersection between line A and the vertical line through the midpoint of the line between anterior superior iliac spine and lateral margin of patella was point A. And then the line between the midpoint of groin and point A was regarded as line B. Based on this , the perforating point of cutaneous branch could be located by Doppler along the line B. From November 2001 to October 2004, this method was used in 38 skin flaps of 37 cases, being all males and 16-48 years old. The area of the flap ranged from 7 cm×6 cm to 24 cm×16 cm. Results All the perforatingpoint of cutaneous branch were located outward the line A. The rate that the preoperative Doppler location was consistent with the utility point of formatting skin flap was 97.4%. All the cases were followed up postoperatively 1-20 months. Among the cases, 36 skin flaps of 35 cases was successful and only 2 skin flaps partially necrosed, which healed after changing dressings or skin graft.Out of 35 cases, the sensation restoration of the skin flap was S2-S3 in 6 cases owing to the anastomosis of lateral femoral cutaneous nerve and a skin nerve of the recipient site, while that of the other cases was S0-S1. Conclusion Preoperative Doppler location and improving design of lineB can be a useful instruction for the design of skin flap pedicled with descending branch of lateral femoral circumflex artery.

    Release date:2016-09-01 09:26 Export PDF Favorites Scan
  • Clinical characteristics of retinal degeneration with retinal holes and the therapeutic effect of argon laser therapy

    Objective To investigate the clinical characteristics of retinal degeneration (RD) with retinal holes and the therapeutic effect of argon laser therapy. Methods The data of argon laser therapy in 210 RD patients (224 eyes) with retinal holes who underwent the treatment in our department were retrospectively analyzed, which was compared with the data of argon laser therapy in 173 RD patients (198 eyes) without retinal holes. Results In RD patients with retinal holes, 89.7% of the patients were less than 60 years old (53.3% males and 46.7% females). Grid-like degeneration was found in 65.6% of the patients in whom 87.5% had the range of degeneration less than 1 quardrant. There were oval-shaped holes in 60.7% of the patients and accompanied with limited rhegmatogenous retinal detachment (LRRD) in 23.7%. Compared with RD patients without retinal holes, the ratio of patients with the age ofge;35 years, cystic degeneration, retinal lengthways small plica, and subjective symptoms was higher in RD patients with retinal holes; while the therapeutic effect of argon laser therapy on patients with LRRD was obviously less than whom without retinal holes (Plt;0.01 ). Conclusions RD with retinal holes often occurs in youth, most of whom have grid-like degeneration with the range of le;1 qua drant. The major types of retinal holes are oval-shaped degeneration without retinal detachment. There was no sex difference in RD patients with retinal holes and most of the patients have no subjective symptoms. The therapeutic effect of prophylactic argon laser therapy on RD patients with retinal holes but no retinal detachment is satisfying. (Chin J Ocul Fundus Dis, 2006, 22: 39-41)

    Release date:2016-09-02 05:51 Export PDF Favorites Scan
  • The multifocal electroretinography in age-related macular degeneration

    Purpose To measure and compare the difference of multifocal electroretinogram in normal subjects and patients with age-related macular degeneration. Methods Seventeen cases(20 eyes)of normal subjects,7 cases(10 eyes)of dry form AMD(age-related macular degeneration),8 cases(8 eyes)of wet-form AMD and 11 cases(11 eyes)of idiopathic macular hole(IMH)were tested with VERIS SciencesTM 4.0 made by EDI company of America.The latencies and average response densities of 6 ring retinal regions in normal subjects were compared with those in various types of age-related maculopathies. Results The N1 and P1 wave latencies of all 6 rings in wet-form AMD and the N1 wave latencies of 3~6 rings in dry-form AMD were delayed statistically.The N1 and P1 wave average response densities of 1~4 rings in and the P1 wave average response densities of 1-6 rings wet-form AMD and the N 1 wave average response densities of 1~5 and the P1 wave average response densties of 1-6 rings in dry-form AMD were decreased statistically.The N1 and P1 wave average response densities of 1~2 and the P1 wave average esponse densities of 1~3 rings were decrease statistically in IMH. Conclusion Multifocal electroretinogram can be used to quantitate the visual function of the affected location in age-related macular degeneration. (Chin J Ocul Fundus Dis,2000,16:224-226)

    Release date:2016-09-02 06:05 Export PDF Favorites Scan
  • Clinical efficiency of operative treatment for retinal detachment caused by macular hole in high myopia

    Objective To observe the clinical effects of surgical treatment of retinal detachment(RD) caused by macular hole(MH) in high myopia. Methods The clinical materials of 149 eyes of 149 high myopia patients with RD caused by MH were reviewed. The cases were divided into complete posterior vitreous detachment (PVD) group and incomplete PVD group. The anatomic successful rate of operative treatment was evaluated according to the applications of vitrectomy surgery and non-vitrectomy surgery respectively in each group. The visual acuity changes after the operations were also observed.Results The anatomic successful rates were as follow: 77.9% in total cases with vitrectomy surgery and 25.9% with non-vitrectomy surgery (P<0.001); 75.5% in cases of incomplete PVD with vitrectomy surgery,and 15.0% with non-vitrectomy surgery (P<0.001); and in non-vitrectomy cases, 57.1 % in complete PVD group and 15.0% in incomplete PVD group (P=0.05). The rates of visual improvement were 68.6% in complete PVD group and 57.0% in incomplete group (P>0.05). Conclusions The scleral buckling combined with vitrectomy, gas intraocular tamponade and postoperative photocoagulation is an effective and optimal procedure for RD caused by MH in high myopia. (Chin J Ocul Fundus Dis,2003,19:8-10)

    Release date:2016-09-02 06:00 Export PDF Favorites Scan
  • Clinical analysis of 47 cases with traumatic macular hole resulted from ocular contusion

    ObjectiveTo analyze the clinical characteristic, treatment and prognosis of traumatic macular holes resulted from ocular contusion. MethodsThe clinical data of 47 cases with traumatic macular hole was retrospectively reviewed. The general condition of the patients was summarized, optical coherence tomography and multifocal electroretinogram (mfERG) were used to evaluate anatomic and functional outcomes. The patients were divided into observation group and surgery group by the treatment they received, and the prognosis was evaluated. ResultsTraumatic macular hole occurs mainly in male. In the observation group, the mean diameter of macular hole was(490.0±86.9)μm. During the 12 month follow-up, the holes in 7 cases (33.3%) were closed spontaneously, Vision and diameters of 14 cases (57.1%) maintained stable for a long time, the vision of 1 case (3.3%) declined mildly and the diameter of 1 case (3.3%) enlarged slightly. Visual acuity was improved significantly at last follow-up (Z=-2.40, P < 0.05). The amplitudes of N1 wave of mfERG increased both in central fovea and macular area(t=13.30, 5.06;P < 0.05).These data suggests that the macular function was recovered well. In the surgery group, the mean diameter of macular hole was(643.3±125.0)μm and statistically larger than that of the observation group (t=-4.76, P < 0.05). At the last follow-up, visual acuity were not improved significantly (Z=-1.79, P > 0.05). The amplitudes of N1 wave in 6 cases (23.1%) improved merely and the difference was not statistically significant(t=1.98, P > 0.05).These data suggests that the macular function was recovered slightly only in a few patients. ConclusionsA part of the patients with smaller diameters of macular holes may close spontaneously, and they may get better visual acuity. Vitrectomy may help to close the macular holes in some severe cases, but the improvement of functional outcomes is not significant.

    Release date: Export PDF Favorites Scan
  • The therapeutic effect of combined surgery of anterior and posterior segment and silicon oil tamponade on macular hole retinal detachment in eyes with high myopia

    Objective To observe the therapeutic effect of combined surgery of anterior and posterior segment and silicon oil tamponade on macular hole retinal detachment in eyes with high myopia.Methods The clinical data of 48 high myopia patients (48 eyes) with macular hole retinal detachment were retrospectively analyzed. Retinal detachment was mainly at the posterior pole; macular hole was confirmed by noncontact Hruby lens and optical coherence tomography (OCT). Phacoemulsification combined with pars plana vitrectomy and silicon oil tamponade were performed to all patients, of which 41 had undergone internal limiting membrane peeling, and 23 had intraocular lens implanting. The oil had been removed 3.5-48.0 months after the first surgery and OCT had been performed before the removal. The followup period after the removal of the silicon oil was more than 1 year.Results The edge of the macular hole could not be seen under the noncontact Hruby lens 1 week after the surgery in all but 5 patients, and the visual acuity improved. The silicon oil had been removed in all of the 48 patients; the OCT scan before the removal showed that the closed macular holes can be in U shape (8 eyes), V shape (6 eyes) or W shape (23 eyes). About 1338 months after the oil removal, retinal detachment recurred in 2 patients with the Wshaped holes. At the end of the followup period, 16 patients (33.3%) had U or Vshaped macular holes, and 32 patients (66.7%) had Wshaped macular holes. The rate of retinal reattachment was 100%.Conclusion Combined surgery of anterior and posterior segment and silicon oil tamponade is effective on macular hole retinal detachment in eyes with high myopia.

    Release date:2016-09-02 05:43 Export PDF Favorites Scan
  • Anatomic evaluation of vitreous surgery of idiopathic macular hole with optical coherence tomography

    Purpose To evaluate the surgical effect of idiopathic macular hole (IMH),with optical coherence tomography (OCT). Methods To measure the diameter of holes and hole halos,the thickness of hole in edge,the changes of hole pattern in 19 cases (19 eyes) with IMH using OCT. Results By quantitatively measuring,OCT showed that after surgery the mean hole diameter lessened from (570.95plusmn;264.59 )mu;m to (337.05plusmn;335.95)mu;m.The mean diameter of hole halo lessened from (1043.53plusmn;278.80)mu;m to (695.00plusmn;483.00)mu;m and the mean thickness of the hole edge thinned from (389.78plusmn;60.58)mu;m to (298.78plusmn;109.80)mu;m.In 17 eyes the holes become closed or reduced in size or the hole halo,and thinned in hole edge.The anatomic successful rate of the surgery is 89%. Conclusion OCT can objectively,accurately and effectively judge the anatomic effect of IMH surgery. (Chin J Ocul Fundus Dis,2000,16:71-138)

    Release date:2016-09-02 06:05 Export PDF Favorites Scan
  • Design and In Vitro Experimental Study of an Endoscopic Multipleclip Applier

    Considering the problems such as reposition limited, easily detached and singly fired of the existing clip products, we developed an endoscopic multiple-clip applier which can apply 4 clips fired successively at a time. The instrument also equipped with an independent grasper which can be used to clamp target tissues. In order to explore its feasibility and effectiveness of endoluminal closure of gastric perforation, 22 pig stomachs were making a 1 cm full-thickness incision from outside and closed by multiple-clip applier (n=12) in vitro. Outcome was measured by bursting pressure and compared with negative control (n=5) and hand suture (n=5). We set a threshold pressure value (10 mm Hg) for a secure closure. Except 2 cases of invalid data, the mean bursting pressures of negative control, multiple-clip applier, hand suture were (1.5±0.3) mm Hg, (46.0±7.1) mm Hg, and (72.5±7.7) mm Hg, respectively. The results showed that bursting pressure of multiple-clip applier was significantly higher than that of negative control (P<0.05) and threshold value. Multiple-clip applier can be served as an effective and safe device to perform the endoluminal closure of gastric perforation.

    Release date: Export PDF Favorites Scan
  • Analysis of factors affecting the visual outcome after vitrectomy for idiopathic macular hole

    ObjectiveTo investigate the factors correlated with the visual outcome of idiopathic macular holes (IMH) after vitreoretinal surgery. MethodsA total of 57 eyes of 57 patients with IMH were included. There were 43 females (43 eyes) and 14 male (14 eyes), mean age was (60.46±4.79) years. All the eyes underwent best corrected visual acuity (BCVA), slit-lamp microscope, three-mirror contact-lens and optical coherence tomography (OCT) examinations. BCVA were examined with interactional visual chart and recorded with logarithm of the minimum angle of resolution (logMAR) acuity. The minimum diameter and base diameter of macular holes and central retinal thickness (CRT) were detected by OCT. The average logMAR BCVA of 57 eyes was 0.98±0.41. The minimum diameter and base diameter of macular holes were (479.53±164.16) μm and (909.14±278.65) μm. All the patients underwent pars plana vitrectomy combined with phacoemulsification cataract extraction and intraocular lens implantation. The mean follow-up period was (173.44±147.46) months. The relationships between final BCVA and these parameters were examined by single and multiple regression analysis. The valuable influence factors were filtrated and formulated using multiple linear regression models. ResultsAt the final follow-up, the logMAR BCVA of 57 eyes was 0.44±0.31, the CRT was (158.79±86.96) μm. The final BCVA was positive related to minimum diameter of macular holes and preoperative BCVA (r=0.420, 0.448; P=0.001, 0.000), negative related to postoperative CRT (r=-0.371, P=0.004). There was no relationship between the final BCVA and base diameter of macular holes, age and follow-up (r=0.203, -0.015, 0.000; P=0.130, 0.913, 0.999). The incidence of preoperative BCVA for postoperative BCVA was bigger than preoperative minimum diameter of macular holes (P=0.008, 0.020). ConclusionThe preoperative minimum diameter of macular holes and BCVA are related to postoperative BCVA in IMH eyes.

    Release date:2016-10-21 09:40 Export PDF Favorites Scan
12 pages Previous 1 2 3 ... 12 Next

Format

Content