【Abstract】 Objective To explore the flexibil ity and rel iabil ity of cementless total knee arthroplasty (TKA) without patellareplacement through a retrospective study of the mid-term therapeutic effect of the treatment of the patients. Methods FromJune 1997 to March 2000, a consecutive series of 152 (152 knees) cementless TKA performed in Hessing-Stiftung was studied. Among them, there were 63 males and 89 females, with 70 left knees and 82 right knees. Their ages ranged from 51 years to 72 years, with an average of 59 years. There were 146 cases of osteoarthritis and 6 cases of traumatic arthritis. The course of the disease lasted for 1.0 years to 3.5 years. The EFK prostheses of German Plus company were used in all the cases. The HSS score before the operation was 41.5 ± 12.3, and the average range of motion was 55º (ranging from 30º to 90º). Results Five patients underwent anterior knee pain, and the pain was released after the appropriate treatment. No deep infection happened in all cases. A total of 145 patients (145 knees) were followed up for 5 years to 8 years. The HSS score was 87.5 ± 8.2 at the end of the follow-up, showing significant difference (P lt; 0.05). The average range of motion was 95º (ranging from 90º to 110º). Partial radiolucencies occurred at the tibia side in 18knees 3 to 6 months after the operation. Among them, the width was less than 2 mm in 15 knees without symptom, and more than 2 mm in 3 knees. There were 2 of the 3 knees which were revised at the tibia side because of the aseptic loosing, while 1 patient had only mild pain in the knee during the follow-up, with no sign of loosing. Conclusion The mid-term effect of cementless TKA is satisfactory. The ingrowth of femur and tibial bones is rel iable. The early stage migration of the component is the main reason of loosing. Satisfying outcomes can also be achieved without patella replacement during TKA.
Objective Using the mono-energy reconstruction images and X-ray films to investigate whether the ABG Ⅱ short-stem could improve the filling ratio, stability, and alignment in the Dorr type C femur, compared with the Corail long-stem. MethodsAmong patients who were with Dorr type C femurs and treated with total hip arthroplasty between January 2006 and March 2012, 20 patients with a Corail long-stem (Corail group) and 20 patients with an ABG Ⅱ short-stem (ABG Ⅱ group) were randomly selected. The differences in gender, age, body mass index, and preoperative diagnoses between the two groups were not significant (P>0.05). The ABG Ⅱ group was with a mean follow-up of 142 months (range, 102-156 months), and the Corail group was with a mean follow-up of 107 months (range, 91-127 months). There was no significant difference in the Harris score and subjective satisfaction score between the two groups at last follow-up (P>0.05). At last follow-up, dual-energy CT scans with mono-energy image reconstruction were used to calculate the prosthetic filling ratio and to measure the alignment of the prosthesis in the coronal and sagittal positions. Stability assessment was performed based on X-ray films, and the subsidence distance was measured using EBRA-FCA software. ResultsX-ray film observation showed that the prostheses in the two groups were stable and no signs of loosening was found. The incidence of pedestal sign was significantly lower in the ABGⅡ group than in the Corail group (P<0.05), and the incidence of heterotopic ossification was significantly higher in the ABGⅡ group than in the Corail group (P<0.05). The subsidence distance of femoral stem in ABG Ⅱ group was significantly greater than that in Corail group (P<0.05), and the subsidence speed of femoral stem in ABG Ⅱ group was also greater than that in Corail group, but the difference was not significant (P>0.05). The overall prosthesis filling ratio was significantly higher in the ABG Ⅱ group than in the Corail group (P<0.05), while the coronal filling ratio at the lesser trochanter, 2 cm below the lesser trochanter, and 7 cm below the lesser trochanter were not significant (P>0.05). The results of prosthesis alignment showed that there was no significant difference in the sagittal alignment error value and the incidence of coronal and sagittal alignment error >3° between the two groups (P>0.05), while the coronal alignment error value in the ABG Ⅱ group was significantly greater than that in the Corail group (P<0.05). Conclusion Although the ABG Ⅱ short-stem avoids the distal-proximal mismatch of the Corail long-stem in the Dorr type C femur and thus achieves a higher filling ratio, it does not appear to achieve better alignment or stability.
OBJECTIVE: Extension stiffness of knee joint is always treated by the quadricepsplasty, but the main deficiency of this method is that patient feels weakness of lower limb and easily kneels down. The aim of this article is to explore the method to resolve the complications after quadricepsplasty. METHODS: Since 1978 to 1997, on the basis of traditional procedures of quadricepsplasty, sartorius muscle was used to reinforce the extension of knee joint. The lower 2/3 of sartorius muscle was fully dissociated only with its insertion intact. A tendon-periosteal-bone flap, about 2 cm in width, was managed on the anterior surface of patella, with its pedicle on the medial edge of patella. The tendon-periosteal-bone flap was used to fix the dissociated sartorious into patella to reinforce the extension of knee joint. The very lower part of sartorius was mainly aponeurosis, with the help of an aponeurosis bundle of iliotibial tract, it was fixed into the insertion of patellar ligament, through a bony tunnel chiseled adjacent to the insertion of patellar ligament. By now the movement of knee joint extension was strengthened by the transferred sartorius muscle. Postoperatively, every patient was required to extend and flex knee joint actively and/or passively. Altogether 12 patients were treated, 9 of them were followed up with an average of 14 months. RESULTS: The average movement was increased from 15 degrees to 102 degrees, and the average myodynamia was improved from grade II to grade IV. CONCLUSION: Traditional quadricepsplasty co-operated with transfer of sartorius muscle can strengthen the myodynamia of knee joint extension. It is simple method and can really achieve good function.
Objective To investigate clinical significanceand surgical protocols about the balance of the lower limb lengths in the total hip arthroplasty. Methods Forty-eight patients undergoing the unilateral primary total hip arthroplasty from March 2000 to October 2004 were retrospectively studied. In 12 hips, the prostheses were of the cement type; in 36 hips, of the mixture type. Thirty patients with an equal limb length had a fractured femoral neck, 10 patients had a shortened (1.0-2.0 cm) limb, 6 patients had a shortened (2.0-4.0 cm)limb, and 2 patients had a shortened (4.0-6.0 cm) limb. Based on the clinical measurement and radiographic examination, the surgical protocols were designed, the hip prosthesis type was chosen, and the neck length of the femoral prosthesis and the position of osteotomy were estimated. By the wearing of the acetabula properly, the best rotation point was found out during the operation. The cut plane of the femoral neck was adjusted according to the results of the radiographic and other examinations. The neck length was readjusted after the insertion of the prosthesis so as to achieve an intended limblength equalization. Results All the patients were followed up for 3-42 months.According to the Harris scoring system, clinical results were excellent in 30 patients, good in 12, fair in4, and poor in 2. Of the 30 patients with an equal limb before operation, 5 were lengthened 1.0-2.0 cm in their lower limbs, and 1 lengthened 2.5 cm postoperatively. Of the 18 patients with shortened limbs before operation, 10 returned to the same lengths in their lower limbs, 6 were lengthened 1.0-2.0 cm in their lower limbs, but 2 with seriously-shortened lower limbs for congenital dysplasia of the hipjoint were still shortened 2.0-3.0 cm in the limb length after operation. The Harris hip scores revealed an average of 92.3 points in the patients with an equal limb length, and 88.6 points in the patients with shortened limbs. 〖WTHZ〗Conclusion Many factors, such as surgical protocols, prosthesis type designs, and the management techniques during the operation, can affect the limb length after operation. As the limb length discrepancy will make the patients feel disappointed, the clinical measurements are very important before operation. Application of the comprehensive appraisal methods during the operation, use of the soft tissuebalance method, and skills for obtaining an equal limb length during the total hip arthroplasty are also important for improving the surgical result further.
Objective To evaluate the effect of remote controlled injection manipulator system (RCIM) assisted percutaneous kyphoplasty (PKP) for the treatment of rupture of posterior vertebral osteoporotic vertebral fracture by comparing with intermittent hand bolus injection of bone cement during operation. Methods Between September 2010 and January 2016, a retrospective analysis was made on the clinical data of 48 senile patients with single segment rupture of the posterior vertebral osteoporotic thoracolumbar fracture undergoing PKP who accorded with the inclusion criteria. Of 48 patients, 22 received intermittent hand bolus injection of bone cement in the control group, and 26 received RCIM assisted bone cement perfusion in the trial group. There was no significant difference in age, gender, duration of disease, causes of injury, implicated vertebral bodies, bone mineral density T value, pain duration, preoperative visual analogue scale (VAS), relative vertebral body height in the anterior part, and posterior convex Cobb angle between groups (P>0.05). The bone cement perfusion time, the radiation dose of both doctors and patients, and the amount of bone cement injection were recorded; treatment effects were evaluated based on VAS score, posterior convex Cobb angle, relative ver-tebral body height in the anterior part, ratios of bone cement diffusion area and bone cement leakage rate. Results The patients were followed up for 6 months; no complications of toxic effect of bone cement, spinal cord or nerve root injuries, infection and vascular embolization occurred during follow-up period. There was no significant difference in bone cement injection amount and radiation dose of doctors between groups (P>0.05), but bone cement perfusion time, ratios of bone cement diffusion area, and radiation dose of patients were significantly lower in the trial group than the control group (P<0.05). Bone cement leakage was observed in 6 cases of the control group (27.27%) and 2 cases of the trial group (7.69%), showing significant difference between groups (χ2=4.850,P=0.029); no cement leakage into the spinal canal was found in both groups. VAS score, relative vertebral body height in the anterior part, and posterior convex Cobb angle were significantly improved at 3 days and 6 months after operation when compared with preoperative ones (P<0.05), but no significant difference was observed in the above indexes between groups at 3 days and 6 months after operation (P>0.05). Conclusion Satisfactory effectiveness can be achieved by applying RCIM assisted PKP for the treatment of rupture of posterior vertebral osteoporotic vertebral fracture. RCIM can shorten perfusion time, reduce radiation dose, and decrease incidence of bone cement leakage.
Objective To investigate the effect of lateral retinacular release on the clinical outcomes after total knee arthroplasty (TKA) without resurfacing of the patella. Methods A prospective randomized controlled study was performed on 132 patients with unilateral degenerative knee arthritis undergoing TKA bewteen October 2012 and October 2014, who met the selection criteria. During TKA, lateral retinacular release was used in 66 cases (trial group) and was not used in 66 cases (control group). Two patients were excluded from the study due to missing the follow-up in trial group. Four patients were excluded from the study due to lateral retinacular release in control group. Finally, 64 patients and 62 patients were included in the trial group and in the control group. There was no significant difference in gender, age, body mass index, side, disease duration, preoperative patellar morphology, grading of patellofemoral arthritis, grade of patellar cartilage degeneration, patellar malposition, patellar maltracking, patellar score, and Knee Society Score (KSS) between 2 groups (P>0.05). The operation time, postoperative drainage volume, hospitalization time, postoperative complications, and patient satisfaction were recorded. Postoperative anterior knee pain was assessed by visual analogue scale (VAS), and the knee joint function was evaluated by KSS score and patellar score. The femoral angle, tibial angle, femoral flexion angle, and tibial posterior slope angle were measured on the X-ray film for postoperative prosthetic alignment. The postoperative patellar tracking and patellar position, as well as the presence of osteolysis, prosthesis loosening, patellar fracture and patellar necrosis were observed. Results All patients were followed up for 24 months. There was no significant difference in operation time, postoperative drainage volume, hospitalization time, and patient satisfaction between 2 groups (P>0.05). The incidence of anterior knee pain in the trial group was better than that in the control group (P=0.033). KSS score and patellar score were significantly improved in both groups at 24 months after operation when compared with preoperative scores (P<0.05), but no significant difference was found between 2 groups (P>0.05). Complications included hematoma (2 cases in the trial group, and 1 case in the control group), mild wound dehiscence (2 cases in each group respectively), skin-edge necrosis (1 case in the trial group), and superficial wound infection (1 case in each group respectively), which were cured by conservative treatment. No patellar necrosis, patella fracture, or knee lateral pain occurred in 2 groups. There was no significant difference in complication rate between groups (P=0.392). Satisfactory implant alignment was observed in both groups during follow-up. There was no significant difference in femoral angle, tibial angle, femoral flexion angle, and tibial posterior slope angle between 2 groups (P>0.05). No radiolucent line at the bone-implant interface was seen around the tibial components and femoral components in both groups. The patellar maltracking was observed in 3 patients of the trial group and 5 patients of the control group, showing no significant difference (P=0.488). However, the incidence of patellar malposition in the trial group (18.8%) was significantly lower than that in the control group (35.5%) (χ2=0.173,P=0.034). Conclusion Lateral retinacular release during primary TKA without resurfacing of the patella can reduce postoperative knee pain without increasing complications.
Objective To systematically evaluate the difference in leg length discrepancy (LLD) between robot-assisted total hip arthroplasty (THA) and traditional THA. Methods The Cochrane Library, PubMed, Web of Science, EMbase, CNKI, Wanfang, VIP, and CBM databases were searched by computer to collect cohort studies of robot-assisted and traditional THAs from inception to August 11th, 2021. Two researchers independently screened the literature, extracted the data, and evaluated the risk of bias of the included studies. Meta-analysis was performed using RevMan 5.3 software. ResultsA total of 10 high-quality cohort studies were included. The results of Meta-analysis showed that compared with traditional THA, LLD after robot-assisted THA was smaller [MD=−1.64, 95%CI (−2.25, −1.04), P<0.001], Harris scores at 3 and 12 months after operation were higher [MD=1.50, 95%CI (0.44, 2.57), P=0.006; MD=7.60, 95%CI (2.51, 12.68), P=0.003]. However, the operative time was longer [MD=8.36, 95%CI (4.56, 12.17), P<0.000 1], and the postoperative acetabular anteversion angle was larger [MD=1.91, 95%CI (1.43, 2.40), P<0.001]. There was no significant difference in Harris score at 6 months, amnesia index (Forgotten joint score, FJS), postoperative acetabular abduction angle, and incidence of complication between the two groups (P>0.05). Conclusion Robot-assisted THA is superior to traditional THA in postoperative LLD.
ObjectiveTo evaluate the effect of the surgeon’s handedness on the distribution of prosthesis during primary total knee arthroplasty (TKA).MethodsA retrospective analysis was performed on 86 patients (100 knees) with primary TKA completed by the same right-handed surgeon between December 2016 and December 2018, including 72 cases of single knee and 14 of bilateral knees. The patients were divided into dominant group (right side) and non-dominant group (left side) according to the operating position of the surgeon and each group had 50 knees. There was no significant difference in gender, age, body mass index, disease duration, clinical diagnosis, preoperative Hospital for Special Surgery (HSS) score, and other general data between the two groups (P>0.05). The operation time and complications were recorded in both groups. The function of knee was evaluated by HSS score. Hip-knee-ankle angle (HKA), mechanical lateral distal femoral angle (mLDFA), and mechanical medial proximal tibial angle (mMPTA) were measured by using X-ray film of full-length lower extremity before TKA and at 2 weeks after TKA that were used to evaluate the coronal position of the prosthesis. Posterior distal femoral angle (PDFA) and posterior proximal tibial angle (PPTA) were measured by using lateral X-ray films at 3 months after operation that were used to evaluate the sagittal position of the prosthesis.ResultsThere was no significant difference in operation time between the two groups (t=−1.128, P=0.262). One case of posterior tibial artery thrombosis occurred in the dominant group, and 1 case of poor healing of the incision occurred in each of the dominant group and the non-dominant group. Patients in both groups were followed up 12-34 months with an average of 22.0 months. The HSS scores at last follow-up were 87.2±4.3 in the dominant group and 86.8±5.0 in the non-dominant group. There was no significant difference between the two groups (t=0.471, P=0.639). No complications such as periprosthetic infection, prosthetic loosening, or periprosthetic fracture occurred during follow-up. There was no significant difference in the HKA, mLDFA, and mMPTA between the two groups before and after operation (P>0.05). The differences in the incidence of sagittal femoral prosthesis malposition and PDFA between the two groups were significant (P<0.05); however, there was no significant difference in the PPTA, the rate of femoral prosthesis distributed in the neutral position, the incidence of over-flexed femoral prosthesis, and the incidence of anterior femoral notch (P>0.05).ConclusionThe surgeon’s handedness is one of the factors affecting the placement of the sagittal femoral prosthesis in primary TKA. The incidence of sagittal femoral prosthesis malposition could increase when the surgeon performs on the non-dominant side.
Objective To explore the effective method and the feasibil ity of the accurate l imb length equal ization in patients undergoing total hip arthroplasty (THA). Methods From September 2006 to September 2008, 52 patients underwentunilateral THA, including 36 males and 16 females, with an average age of 61.5 years (range, 46-76 years). Among these cases, there were 22 cases of avascular necrosis of the femoral head, 12 cases of hip osteoarthritis, 11 cases of femoral neck fracture, 4 cases of congenital dislocation of hip, and 3 cases of acetabular dysplasia. Forty cases had leg length discrepancy, and the shortened length of the legs was in the range of 10 mm to 35 mm with an average of 20 mm. The mean Harris score before operation was 45 points (range, 36-58 points). Based on the cl inical measurement and radiographic examination, the surgical protocols were designed, the type of the hip prosthesis was chosen, and the neck length of the femoral prosthesis, and the position of osteotomy were estimated. By the proper wearing of the acetabula, the best rotation point was found out. The cut plane of the femoral neck was adjusted according to the results of the radiographic and other examinations. The neck length was readjusted after the insertion of the prosthesis so as to achieve intended leg-length equal ization. The discrepancy of the leg length was measured and evaluated after operation. Results The incision healed by first intention in all patients. One patient had ischiadic nerve palsy and achieved full restoration after 5 months of symptomatic management. Forty-four patients were followed up 16 months on average (7-32 months). The mean Harris score was 87.5 points (80-91 points), showing significant difference (P lt; 0.05) whencompared with that before operation. The l imb length equal ization were got in 35 patients (equal ization rate was 79.5%). Seven patients had the prolong leg (from 10 mm to 18 mm), 2 patients had the shortened legs (15 mm and 25 mm, respectively). Conclusion By measurement of leg-length and radiographic examination before and during operation, the problem of unequal leg - length can be solved during the THA.
OBJECTIVE To review the history and current status of total wrist arthroplasty. METHODS The original articles about wrist arthroplasty in recent years were reviewed. RESULTS The properties of wrist prosthesis of different generations were reviewed, with the emphasis on the prosthesis design and biomechanical behaviours. The surgical techniques, complications and salvage procedures were also discussed. CONCLUSION Although wrist arthrodesis is highly successful in treating the end-stage wrist arthritis, total wrist arthroplasty using well-designed prosthesis remains an alternative for the patients with special demands of hand functions.