Focused on the world-wide issue of improving the accuracy of emotion recognition, this paper proposes an electroencephalogram (EEG) signal feature extraction algorithm based on wavelet packet energy entropy and auto-regressive (AR) model. The auto-regressive process can be approached to EEG signal as much as possible, and provide a wealth of spectral information with few parameters. The wavelet packet entropy reflects the spectral energy distribution of the signal in each frequency band. Combination of them gives a better reflect of the energy characteristics of EEG signals. Feature extraction and fusion are implemented based on kernel principal component analysis. Six emotional states from a public multimodal database for emotion analysis using physiological signals (DEAP) are recognized. The results show that the recognition accuracy of the proposed algorithm is more than 90%, and the highest recognition accuracy is 99.33%. It indicates that this algorithm can extract the feature of EEG emotion well, and it is a kind of effective emotion feature extraction algorithm, providing support to emotion recognition.
The traditional method of multi-parameter flow data clustering in flow cytometry is to mainly use professional software to manually set the door and circle out the target cells for analysis. The analysis process is complex and professional. Based on this, a clustering algorithm, which is based on t-distributed stochastic neighbor embedding (t-SNE) algorithm for multi-parameter stream data, is proposed in the paper. In this algorithm, the Euclidean distance of sample data in high dimensional space is transformed into conditional probability to represent similarity, and the data is reduced to low dimensional space. In this paper, the stained human peripheral blood cells were treated by flow cytometry, and the processed data were derived as experimental sample data. Thet-SNE algorithm is compared with the kernel principal component analysis (KPCA) dimensionality reduction algorithm, and the main component data obtained by the dimensionality reduction are classified using K-means algorithm. The results show that thet-SNE algorithm has a good clustering effect on the cell population with asymmetric and trailing distribution, and the clustering accuracy can reach 92.55%, which may be helpful for automatic analysis of multi-color multi-parameter flow data.
Aiming at feature selection problem of motor imagery task in brain computer interface (BCI), an algorithm based on mutual information and principal component analysis (PCA) for electroencephalogram (EEG) feature selection is presented. This algorithm introduces the category information, and uses the sum of mutual information matrices between features under different motor imagery category to replace the covariance matrix. The eigenvectors of the sum matrix represent the direction of the principal components and the eigenvalues of the sum matrix are used to determine the dimensionality of principal components. 2005 International BCI competition data set was used in our experiments, and four feature extraction methods were adopted, i. e. power spectrum estimation, continuous wavelet transform, wavelet packet decomposition and Hjorth parameters. The proposed feature selection algorithm was adopted to select and combine the most useful features for classification. The results showed that relative to the PCA algorithm, our algorithm had better performance in dimensionality reduction and in classification accuracy with the assistance of support vector machine classifier under the same dimensionality of principal components.
Objective To propose a heart sound segmentation method based on multi-feature fusion network. Methods Data were obtained from the CinC/PhysioNet 2016 Challenge dataset (a total of 3 153 recordings from 764 patients, about 91.93% of whom were male, with an average age of 30.36 years). Firstly the features were extracted in time domain and time-frequency domain respectively, and reduced redundant features by feature dimensionality reduction. Then, we selected optimal features separately from the two feature spaces that performed best through feature selection. Next, the multi-feature fusion was completed through multi-scale dilated convolution, cooperative fusion, and channel attention mechanism. Finally, the fused features were fed into a bidirectional gated recurrent unit (BiGRU) network to heart sound segmentation results. Results The proposed method achieved precision, recall and F1 score of 96.70%, 96.99%, and 96.84% respectively. Conclusion The multi-feature fusion network proposed in this study has better heart sound segmentation performance, which can provide high-accuracy heart sound segmentation technology support for the design of automatic analysis of heart diseases based on heart sounds.
The deep learning-based automatic detection of epilepsy electroencephalogram (EEG), which can avoid the artificial influence, has attracted much attention, and its effectiveness mainly depends on the deep neural network model. In this paper, an attention-based multi-scale residual network (AMSRN) was proposed in consideration of the multiscale, spatio-temporal characteristics of epilepsy EEG and the information flow among channels, and it was combined with multiscale principal component analysis (MSPCA) to realize the automatic epilepsy detection. Firstly, MSPCA was used for noise reduction and feature enhancement of original epilepsy EEG. Then, we designed the structure and parameters of AMSRN. Among them, the attention module (AM), multiscale convolutional module (MCM), spatio-temporal feature extraction module (STFEM) and classification module (CM) were applied successively to signal reexpression with attention weighted mechanism as well as extraction, fusion and classification for multiscale and spatio-temporal features. Based on the Children’s Hospital Boston-Massachusetts Institute of Technology (CHB-MIT) public dataset, the AMSRN model achieved good results in sensitivity (98.56%), F1 score (98.35%), accuracy (98.41%) and precision (98.43%). The results show that AMSRN can make good use of brain network information flow caused by seizures to enhance the difference among channels, and effectively capture the multiscale and spatio-temporal features of EEG to improve the performance of epilepsy detection.
The brain computer interface (BCI) can be used to control external devices directly through electroencephalogram (EEG) information. A multi-linear principal component analysis (MPCA) framework was used for the limitations of tensor form of multichannel EEG signals processing based on traditional principal component analysis (PCA) and two-dimensional principal component analysis (2DPCA). Based on MPCA, we used the projection of tensor-matrix to achieve the goal of dimensionality reduction and features exaction. Then we used the Fisher linear classifier to classify the features. Furthermore, we used this novel method on the BCI competitionⅡdataset 4 and BCI competitionⅣdataset 3 in the experiment. The second-order tensor representation of time-space EEG data and the third-order tensor representation of time-space-frequency EEG data were used. The best results that were superior to those from other dimensionality reduction methods were obtained by much debugging on parameter P and testQ. For two-order tensor, the highest accuracy rates could be achieved as 81.0% and 40.1%, and for three-order tensor, the highest accuracy rates were 76.0% and 43.5%, respectively.
The result of the emotional state induced by music may provide theoretical support and help for assisted music therapy. The key to assessing the state of emotion is feature extraction of the emotional electroencephalogram (EEG). In this paper, we study the performance optimization of the feature extraction algorithm. A public multimodal database for emotion analysis using physiological signals (DEAP) proposed by Koelstra et al. was applied. Eight kinds of positive and negative emotions were extracted from the dataset, representing the data of fourteen channels from the different regions of brain. Based on wavelet transform, δ, θ, α and β rhythms were extracted. This paper analyzed and compared the performances of three kinds of EEG features for emotion classification, namely wavelet features (wavelet coefficients energy and wavelet entropy), approximate entropy and Hurst exponent. On this basis, an EEG feature fusion algorithm based on principal component analysis (PCA) was proposed. The principal component with a cumulative contribution rate more than 85% was retained, and the parameters which greatly varied in characteristic root were selected. The support vector machine was used to assess the state of emotion. The results showed that the average accuracy rates of emotional classification with wavelet features, approximate entropy and Hurst exponent were respectively 73.15%, 50.00% and 45.54%. By combining these three methods, the features fused with PCA possessed an accuracy of about 85%. The obtained classification accuracy by using the proposed fusion algorithm based on PCA was improved at least 12% than that by using single feature, providing assistance for emotional EEG feature extraction and music therapy.
Brain-computer interface (BCI) systems identify brain signals through extracting features from them. In view of the limitations of the autoregressive model feature extraction method and the traditional principal component analysis to deal with the multichannel signals, this paper presents a multichannel feature extraction method that multivariate autoregressive (MVAR) model combined with the multiple-linear principal component analysis (MPCA), and used for magnetoencephalography (MEG) signals and electroencephalograph (EEG) signals recognition. Firstly, we calculated the MVAR model coefficient matrix of the MEG/EEG signals using this method, and then reduced the dimensions to a lower one, using MPCA. Finally, we recognized brain signals by Bayes Classifier. The key innovation we introduced in our investigation showed that we extended the traditional single-channel feature extraction method to the case of multi-channel one. We then carried out the experiments using the data groups ofⅣ_ⅢandⅣ_Ⅰ. The experimental results proved that the method proposed in this paper was feasible.
This paper aims to assist the individual clinical diagnosis of children with attention-deficit/hyperactivity disorder using electroencephalogram signal detection method. Firstly, in our experiments, we obtained and studied the electroencephalogram signals from fourteen attention-deficit/hyperactivity disorder children and sixteen typically developing children during the classic interference control task of Simon-spatial Stroop, and we completed electroencephalogram data preprocessing including filtering, segmentation, removal of artifacts and so on. Secondly, we selected the subset electroencephalogram electrodes using principal component analysis (PCA) method, and we collected the common channels of the optimal electrodes which occurrence rates were more than 90% in each kind of stimulation. We then extracted the latency (200~450 ms) mean amplitude features of the common electrodes. Finally, we used the k-nearest neighbor (KNN) classifier based on Euclidean distance and the support vector machine (SVM) classifier based on radial basis kernel function to classify. From the experiment, at the same kind of interference control task, the attention-deficit/hyperactivity disorder children showed lower correct response rates and longer reaction time. The N2 emerged in prefrontal cortex while P2 presented in the inferior parietal area when all kinds of stimuli demonstrated. Meanwhile, the children with attention-deficit/hyperactivity disorder exhibited markedly reduced N2 and P2 amplitude compared to typically developing children. KNN resulted in better classification accuracy than SVM classifier, and the best classification rate was 89.29% in StI task. The results showed that the electroencephalogram signals were different in the brain regions of prefrontal cortex and inferior parietal cortex between attention-deficit/hyperactivity disorder and typically developing children during the interference control task, which provided a scientific basis for the clinical diagnosis of attention-deficit/hyperactivity disorder individuals.
Spike recorded by multi-channel microelectrode array is very weak and susceptible to interference, whose noisy characteristic affects the accuracy of spike detection. Aiming at the independent white noise, correlation noise and colored noise in the process of spike detection, combining principal component analysis (PCA), wavelet analysis and adaptive time-frequency analysis, a new denoising method (PCWE) that combines PCA-wavelet (PCAW) and ensemble empirical mode decomposition is proposed. Firstly, the principal component was extracted and removed as correlation noise using PCA. Then the wavelet-threshold method was used to remove the independent white noise. Finally, EEMD was used to decompose the noise into the intrinsic modal function of each layer and remove the colored noise. The simulation results showed that PCWE can increase the signal-to-noise ratio by about 2.67 dB and decrease the standard deviation by about 0.4 μV, which apparently improved the accuracy of spike detection. The results of measured data showed that PCWE can increase the signal-to-noise ratio by about 1.33 dB and reduce the standard deviation by about 18.33 μV, which showed its good denoising performance. The results of this study suggests that PCWE can improve the reliability of spike signal and provide an accurate and effective spike denoising new method for the encoding and decoding of neural signal.