Pulse waves contain rich physiological and pathological information of the human vascular system. The pulse wave diagnosis systems are very helpful for the clinical diagnosis and treatment of cardiovascular diseases. Accurate pulse waveform is necessary to evaluate the performances of the pulse wave equipment. However, it is difficult to obtain accurate pulse waveform due to several kinds of physiological and pathological conditions for testing and maintaining the pulse wave acquisition devices. A pulse wave generator was designed and implemented in the present study for this application. The blood flow in the vessel was simulated by modeling the cardiovascular system with windkessel model. Pulse waves can be generated based on the vascular systems with four kinds of resistance. Some functional models such as setting up noise types and signal noise ratio (SNR) values were also added in the designed generator. With the need of portability, high speed dynamic response, scalability and low power consumption for the system, field programmable gate array (FPGA) was chosen as hardware platform, and almost all the works, such as developing an algorithm for pulse waveform and interfacing with memory and liquid crystal display (LCD), were implemented under the flow of system on a programmable chip (SOPC) development. When users input in the key parameters through LCD and touch screen, the corresponding pulse wave will be displayed on the LCD and the desired pulse waveform can be accessed from the analog output channel as well. The structure of the designed pulse wave generator is simple and it can provide accurate solutions for studying and teaching pulse waves and the detection of the equipments for acquisition and diagnosis of pulse wave.
Aiming at the problem of scaffold degradation in bone tissue engineering, we studied the feasibility that controlls bone defect repair effect with the inhomogeneous structure of scaffold. The prediction model of bone defect repair which contains governing equations for bone formation and scaffold degradation was constructed on the basis of analyzing the process and main influence factors of bone repair in bone tissue engineering. The process of bone defect repair and bone structure after repairing can be predicted by combining the model with finite element method (FEM). Bone defect repair effects with homogenous and inhomogeneous scaffold were simulated respectively by using the above method. The simulation results illustrated that repair effect could be impacted by scaffold structure obviously and it can also be controlled via the inhomogeneous structure of scaffold with some feasibility.
Atherosclerotic plaque rupture is the main cause of many cardiovascular diseases, and biomechanical factors play an important role in the process of plaque rupture. In the study of plaque biomechanics, there are relatively few studies based on fatigue fracture failure theory, and most of them mainly focus on the whole fatigue propagation process from crack initiation to plaque rupture, while there are few studies on the influence of crack on plaque rupture at a certain time in the process of fatigue propagation. In this paper, a two-dimensional plaque model with crack was established. Based on the theory of fracture mechanics and combined with the finite element numerical simulation method, the stress intensity factor (SIF) and related influencing factors at the crack tip in the plaque were studied. The SIF was used to measure the influence of crack on plaque rupture. The results show that the existence of crack can lead to local stress concentration, which increases the risk of plaque rupture. The SIF at the crack tip in the plaque was positively correlated with blood pressure, but negatively correlated with fibrous cap thickness and lipid pool stiffness. The effect of the thickness and angle of lipid pool on the SIF at the crack tip in the plaque was less than 4%, which could be ignored. This study provides a theoretical basis for the risk assessment of plaque rupture with cracks.
Due to their diverse types, complex causes, high incidence, and difficult treatment, lung diseases have become major killers threatening human life and health, and some lung diseases have a significant impact on alveolar morphology and histology. Numerical simulation of alveolar mechanical response, alveolar flow field information, multiphase flow, and material transport based on computational fluid dynamics is of great significance for lung disease diagnosis, clinical treatment, and in vitro experiments. Starting from the simplification and pathological differences of geometric and mechanical models, this paper analyzes and summarizes the conditions and application scenarios of the airflow dynamics calculation method in pulmonary alveoli, to provide a reference for further simulation and application of the alveolar region.
ObjectiveTo analyze the effect of 3D simulation technique in thoracoscopic lobectomy.MethodsFrom June 2015 to January 2018, 124 patients with left lower lobe resection underwent thoracoscopy with single-port thoracoscopic surgery, including 64 males and 60 females, aged 42–83 years. They were randomly divided into two groups including an experimental group (preoperatively given 3D simulation surgery in 59 patients) and a control group (preoperatively not given 3D simulation surgery in 65 patients). The clinical effect between the two groups was compared.ResultsAll patients recovered without any death during hospitalization. In the experimental group, the operation time, intraoperative blood loss and postoperative hospital stay were significantly less than those in the control group (P<0.05). There was no significant difference in postoperative drainage volume, and duration of drainage tube retention and analgesic drug usage between the two groups (P>0.05).Conclusion3D simulation technique for thoracoscopic lobectomy has advantage in short operation time, minor trauma and quick recovery. It has a guiding role in the preoperative planning of lung cancer surgery and is worthy of popularization and application.
ObjectiveTo investigate the effects of medical simulation (MST) combined with case-based learning (CBL) in training of trainee doctors in emergency department. MethodA total of 120 trainee doctors practicing in the emergency department between March 2008 and December 2014 were randomly divided into two groups:MST combined with CBL group and CBL group, who accepted MST combined with CBL training and merely CBL training, respectively. The training effects were evaluated in terms of theoretical knowledge, practical operation, comprehensive abilities of case analysis and questionnaire survey. The results were compared and analyzed with the t test. The P value less than 0.05 was a significant difference. ResultsTrainee doctors in MST combined with CBL group acquired higher scores in all of the indicators (P<0.05). ConclusionsMST combined with CBL is a feasible method and has a better effect in training of trainee doctors in Emergency Department.
Brain-controlled wheelchair (BCW) is one of the important applications of brain-computer interface (BCI) technology. The present research shows that simulation control training is of great significance for the application of BCW. In order to improve the BCW control ability of users and promote the application of BCW under the condition of safety, this paper builds an indoor simulation training system based on the steady-state visual evoked potentials for BCW. The system includes visual stimulus paradigm design and implementation, electroencephalogram acquisition and processing, indoor simulation environment modeling, path planning, and simulation wheelchair control, etc. To test the performance of the system, a training experiment involving three kinds of indoor path-control tasks is designed and 10 subjects were recruited for the 5-day training experiment. By comparing the results before and after the training experiment, it was found that the average number of commands in Task 1, Task 2, and Task 3 decreased by 29.5%, 21.4%, and 25.4%, respectively (P < 0.001). And the average number of commands used by the subjects to complete all tasks decreased by 25.4% (P < 0.001). The experimental results show that the training of subjects through the indoor simulation training system built in this paper can improve their proficiency and efficiency of BCW control to a certain extent, which verifies the practicability of the system and provides an effective assistant method to promote the indoor application of BCW.
This article describes a novel Multifunctional and Transparent Urinary System Model (MTUSM),which can be applied to anatomy teaching, operational training of clinical skills as well as simulated experiments in vitro. This model covers kidneys, ureters, bladder, prostate, male and female urethra, bracket and pedestal,etc. Based on human anatomy structure and parameters, MTUSM consists of two transparent layers i.e. transparent organic glass external layer,which constraints the internal layer and maintains shape of the model, and transparent silica gel internal layer, which possesses perfect elasticity and deformability. It is obvious that this model is preferable in simulating the structure of human urinary system by applying hierarchical fabrication. Meanwhile, the transparent design, which makes the inner structure, internal operations and experiments visual,facilitates teaching instruction and understanding. With the advantages of simple making, high-findelity, unique structure and multiple functions, this model will have a broad application prospect and great practical value.
Objective To explore the effectiveness and predictive value of computer simulated thoracic endovascular aortic repair (TEVAR). Methods The clinical data of the patients with Stanford type B aortic dissection who underwent TEVAR from February 2019 to February 2022 in our hospital was collected. According to whether there was residual false cavity around the stent about 1 week after TEVAR, the patients were divided into a false cavity closure group and a false cavity residual group. Based on computer simulation, personalized design and three-dimensional construction of the stent framework and covering were carried out. After the stent framework and membrane were assembled, they were pressed and placed into the reconstructed aortic dissection model. TEVAR computer simulation was performed, and the simulation results were analyzed for hemodynamics to obtain the maximum blood flow velocity and maximum wall shear stress at the false lumen outlet level at the peak systolic velocity of the ventricle, which were compared with the real hemodynamic data of the patient after TEVAR surgery. The impact of hemodynamics on the residual false lumen around the stent in the near future based on computer simulation of hemodynamic data after TEVAR surgery was further explored. Results Finally a total of 28 patients were collected, including 24 males and 4 females aged 53.390±11.020 years. There were 18 patients in the false cavity closure group, and 10 patients in the false cavity residual group. The error rate of shear stress of the distal decompression port of the false cavity after computer simulation TEVAR was 6%-25%, and the error rate of blood flow velocity was 3%-31%. There was no statistical difference in age, proportion of male, history of hypertension, history of diabetes, smoking history, prothrombin time or activated partial thromboplatin time at admission between the two groups (all P>0.05). The blood flow velocity and shear stress after TEVAR were statistically significant (all P<0.05). The maximum shear stress (OR=1.823, P=0.010) of the false cavity at the level of the distal decompression port after simulated TEVAR was an independent risk factor for the residual false cavity around the stent. Receiver operating characteristic curve analysis showed that the area under the curve corresponding to the maximum shear stress of false cavity at the level of distal decompression port after simulated TEVAR was 0.872, the best cross-sectional value was 8.469 Pa, and the sensitivity and specificity were 90.0% and 83.3%, respectively. Conclusion Computers can effectively simulate TEVAR and perform hemodynamic analysis before and after TEVAR surgery through simulation. Maximum shear stress at the decompression port of the distal end of the false cavity is an independent risk factor for the residual false cavity around the stent. When it is greater than 8.469 Pa, the probability of residual false cavity around the stent increases greatly.
This paper makes persuasive demonstrations on some problems about the human ear sound transmission principle in existing physiological textbooks and reference books, and puts forward the authors' view to make up for its literature. Exerting the knowledge of lever in physics and the acoustics theory, we come up with an equivalent simplified model of manubrium mallei which is to meet the requirements as the long arm of the lever. We also set up an equivalent simplified model of ossicular chain--a combination of levers of ossicular chain. We disassemble the model into two simple levers, and make full analysis and demonstration on them. Through the calculation and comparison of displacement amplitudes in both external auditory canal air and internal ear lymph, we may draw a conclusion that the key reason, which the sound displacement amplitude is to be decreased to adapt to the endurance limit of the basement membrane, is that the density and sound speed in lymph is much higher than those in the air.