Objective To evaluate the accuracy of pedicle guide device for the placement of the pedicle screws. Methods Pedicle guide device was designed and made for the anatomical trait of pedicle. The 3-Danatomical data of the thoracic pedicles were measured by multislice spiral CT in two embalmed human cadaveric thoracic pedicles spine(T1 -T10). Depending on transverse section angle(TSA) and sagittal section angle(SSA) of pedicle axis, the degree of horizontal dial and sagittal dial were adjusted in the guide device. The screws wereinserted bilaterally in the thoracic pedicles by using the device. After pulling the screws out, the pathways were filled with contrast media. The TSA and SSA of developed pathways were measured. Results Analysis of the difference between pedicle axis and developed pathway was of no statistical significance(P>0.05). Conclusion The guide device could be easilyoperated and guarantee high accuracy of the pathways of screws and the incidence of pedicle penetration could be significantly reduced.
ObjectiveTo summarize controversy and progress of multi-slice spiral CT in efficacy evaluation of transformation therapy for advanced gastric cancer.MethodThe recent studies published at home and abroad on the spiral CT in evaluating the therapeutic effect of transformation therapy for the advanced gastric cancer were reviewed and analyzed.ResultsIn recent years, though the energy spectrum and dual-energy CT examinations had appeared, the most common tool in evaluating of the efficacy of transformation therapy for the advanced gastric cancer was the spiral CT. The most common evaluation standard was still the RECIST standard.ConclusionsSpiral CT has its outstanding diagnostic significance in therapeutic evaluation of transformation therapy for advanced gastric cancer. Although there is some controversy, with advancements of a large number of studies, it will greatly help diagnosis and treatment of advanced gastric cancer.
Objective To compare diagnosis values of computed tomography (CT) and magnetic resonance imaging (MRI) in preoperative staging of rectal carcinoma. Methods The imaging data of 81 patients with rectal carcinoma from January 2013 to January 2017 in the Hefei Second People’s Hospital were retrospectively analyzed. Based on the postoperative pathological results, the diagnostic accordance rates of CT and MRI on the T staging and N staging were calculated. Results The sensitivities of the CT and MRI on the preoperative T staging of rectal carcinoma were 69.1% (56/81) and 82.5% (52/63), the difference was not statistically significant (χ2=3.396, P=0.065), the Kappa values was 0.521 and 0.371, respectively, the MRI on the T staging was in a good agreement with the pathological diagnosis. The sensitivitie of the T1-2, T3, and T4 stagings with CT was 70.0%, 66.7%, and 72.0%, respectively, with MRI was 83.3%, 83.3%, and 81.0%, respectively, which had no significant difference respectively between the CT and the MRI. The areas under the receiver operating characteristic curve of the T1-2, T3, and T4 stagings with the CT and MRI were 0.809, 0.689, 0.798 and 0.897, 0.826, 0.869, respectively. The sensitivities of the CT and MRI on the preoperative N staging of rectal carcinoma were 59.3% (48/81) and 65.1% (41/63), the difference was not statistically significant (χ2=0.509, P=0.476), the Kappa values were 0.371 and 0.463, respectively. The sensitivities of the N0, N1, N2 stagings with CT were 64.7%, 45.5%, 64.0%, with MRI were 70.3%, 63.2%, 72.5%, which had no significant difference respectively between the CT and the MRI. Conclusions Results of in this study show that MRI is superior to CT for judgment of tumor infiltration. Neither CT nor MRI is able to provide satisfactory assessment of lymph node metastasis.
ObjectiveTo summarize the clinical features and imaging features of CT in the omental torsion, and in order to reduce the misdiagnosis and missed diagnosis rate of imaging features. MethodsThe data of 16 cases of omental torsion (secondary 15 cases, primary 1 case) and 286 cases of acute appendicitis (eliminated the subhepatic and retroperitoneal ectopic appendix) in our hospital from 1998 to 2014 were retrospectively analyzed. ResultsEleven cases of omental torsion suffered from the shifting pain in right lower quadrant. No obvious shifting abdominal pain was observed in other 4 cases whose main manifestations were abdominal tenderness and rebound tenderness around umbilicus. The patient of the remaining 1 case had enclosed mass in the area of left groin with pain and suffered from continuous periumbilical pain. Abdominal spiral CT examination was performed in 16 patients before operation. Increased signal intensity of globular soft tissue, which deviating from McBurney's point, was found at level of distal umbilicus by preoperative spiral CT in 13 cases. One case of omental torsion associated with ncarcerated inguinal hernia was missed. ConclusionsOmental torsion manifests chiefly shifting pain in right lower quadrant, abdominal tenderness, and rebound tenderness around umbilicus. It is easily confused with appendicitis. Abdominal spiral CT should be chosen as a preferred means in preoperative diagnosis of omental torsion.
Objective To explore the value of multi-slice spiral CT (MSCT) 3D imaging in evaluating the efficacy of neoadjuvant chemotherapy for advanced gastric cancer. MethodsSixty-one patients with gastric cancer diagnosed by gastroscopy and pathological examination at the First Hospital of Lanzhou University from January 2019 to March 2022 were divided into chemotherapy effective group (n=39) and ineffective group (n=22) according to postoperative pathological regression grade (tumor regression grade, TRG) standards. MSCT was performed before neoadjuvant chemotherapy and before undergoing surgical treatment after neoadjuvant chemotherapy. The independent predictors related to the efficacy of chemotherapy were screened by binary logistics regression analysis of CT conventional observation indexes (including maximum tumor thickness, gastric wall motility, enhancement mode, lymph node metastasis, distant metastasis, peritoneal thickening or peritoneal nodules). Tumor volume and maximum tumor thickness were measured with the imaging histology software ITK-snap, and the diagnostic efficacy of tumor volume and CT conventional observation indexes was analyzed. Results In the evaluation of chemotherapy efficacy, tumor volume reduction rate and tumor maximum thickness reduction rate can evaluate the efficacy of chemotherapy to a certain extent (P< 0.01). The statistically significant indicators (tumor maximum thickness reduction rate, gastric wall motility, lesion intensification mode and peritoneal thickening and nodules) were analyzed by univariate analysis and binary logistic regression. The results showed that gastric wall motility [OR=0.294, 95%CI (0.093, 0.928), P=0.037] and maximum tumor thickness reduction rate [OR=0.282, 95%CI (0.083, 0.957), P=0.042] were independent predictors of the efficacy of neoadjuvant chemotherapy for progressive gastric cancer. Receiver operating characteristic (ROC) curve were plotted based on the predicted probability variable obtained from both and the results showed that the area under curve (AUC=0.900) , sensitivity (83.3%), and specificity (99.8%) of the tumor volume reduction rate were all higher than those of CT clinical index prediction probability variables (AUC=0.802, sensitivity was 58.3%, specificity was 85.7%). ConclusionThe measurement of tumor volume by MSCT combined with the imaging omics software ITK-snap provides an objective basis for the prediction of the efficacy of neoadjuvant chemotherapy, and its diagnostic efficacy is better.
Objective To investigate multi-slice spiral CT (MSCT) and MRI features of stasis cirrhosis and the diagnostic value of MSCT and MRI. Methods MSCT and MRI findings of 35 patients with stasis cirrhosis were studied. The size of liver and spleen, the diameter of hepatic vein (HV), enhancement pattern of liver parenchyma, contrast medium reflux in inferior vena cava (IVC) and (or) HV, ascites, number of varices and correlated abnormalities were reviewed. Results The volume index of liver and spleen of 35 patients was 4434.95 cm3 and 621.92 cm3 respectively. The mean diameter of HV of 27 patients (77.1%) was 3.61 cm and HV of other 8 patients (22.9%) were too small to show. Number of patients showed waves of borderline, inhomogeneous pattern of parenchymal contrast enhancement, contrast medium reflux in IVC and (or) HV, varices and ascites was 5 (14.3%), 29 (82.9%), 20 (57.1%), 16 (45.7%), and 6 (17.1%), respectively. Correlated abnormalities included cardiac enlargement 〔4 cases (11.4%)〕, pericardium thickening 〔11 cases (31.4%)〕, and pericardial effusion 〔2 cases (5.7%)〕. Conclusions Stasis cirrhosis mainly demonstrate liver enlargement, inhomogeneous pattern of parenchymal contrast enhancement, contrast medium reflux in IVC and (or) HV, and slight portal hypertension. MSCT and MRI play invaluable roles in diagnosis, differential diagnosis and etiological diagnosis of stasis cirrhosis.
Objective To evaluate the directional significance of SurgiCase software in free fibula mandibular reconstruction. Methods Between September 2010 and March 2012, 10 patients with mandibular defect underwent free fibula mandibular reconstruction. There were 7 males and 3 females, with an age range of 19-43 years (mean, 27 years). The extent of lesions was 7 cm × 5 cm to 16 cm × 8 cm. In each case, three-dimensional spiral CT scan of the maxilla, mandible, and fibula was obtained before surgery. The CT data were imported into the SurgiCase software and the virtual surgery planning was performed. After that, the mandibular rapid prototyping was made according to customized design. The reconstruction surgery was then carried out using these preoperative data. During actual surgery, the extent of mandibular defect was from 6 cm × 3 cm to 16 cm × 5 cm; the length of fibula which was used to reconstruct mandible was 6-17 cm; and the area of flap was from 6 cm × 5 cm to 16 cm × 6 cm. Results Preoperative data could not be applied because the intraoperative size of tumor was larger than preoperative design in 1 case of mandibular ameloblastoma, and the fibula was shaped according to the actual osteotomy location; operations were performed successfully according to preoperative design in the other 9 patients. The operation time was 5-7 hours (mean, 6 hours). Primary healing of incision was obtained, without early complications. Ten patients were followed up 1 year. At last follow-up, 8 patients were satisfactory with the appearance and 2 patients complained with unsatisfied wide facial pattern. The panoramic radiograghs showed good bone healing. The range of mouth opening was 2.5-3.5 cm. Conclusion SurgiCase software can provide precise data for free fibula mandibular reconstruction during surgery. It can be applied widely in clinic.
Objective To study the feasibil ity and rel iabil ity of the multi-plannar reformation (MPR) of multispiral CT (MSCT) in measuring the kyphosis angle (KA) after thoracolumbar fracture. Methods From December 2007 to December 2009, 45 thoracolumbar fracture patients who underwent computed radiology (CR) and MSCT were recruited. There were 32 males and 13 females with a mean age of 48 years (range, 24-63 years), including 36 simple compression fractures and 9 burst fractures. The fracture locations were T11 in 6 cases , T12 in 11 cases, L1 in 20 cases, and L2 in 8 cases. Fracture was caused by trafffic accident in 25 cases, by fall ing from height in 12 cases, and by others in 8 cases. The imaging examination was performed after 2 hours to 7 days of injury in 22 cases and after more than 7 days in 23 cases. The KA was measured on the lateral X-ray films of CR and MPR by two observers, then the measurements were done again after three weeks. The data were statistically analyzed. Results The average KA values on CR by two observers were (20.75 ± 8.31)° and (22.49 ± 9.07)°, respectively; showing significant difference (P lt; 0.05), and the correlation was good (r=0.882, P lt; 0.05). The average KA values on MPR by two observers were (16.65 ± 8.62)° and (17.08 ± 7.88)°, respectively, showing no significant difference (P gt; 0.05), the correlation was excellent (r=0.976, P lt; 0.05). The average KA values on CR and MPR were (21.61 ± 8.43)° and (16.87 ± 8.20)°, respectively; showing significant difference (P lt; 0.05), the correlation was good (r=0.852, P lt; 0.05). Conclusion It is more feasible and rel iable in measuring the KA on MRP of MSCT than CR, but the value is larger on CR.
ObjectiveTo explore the differences and similarities of the featurs of lymph node metatasis of abdominal esophageal carcinoma and cardiac cancer. MethodsPreoperative CT images of abdominal esophageal carcinomas and cardiac cancers were reviewed and analysed on lymph node size and preponderant distribution. ResultsShort diameter ≥10 mm of lymph node at CT was adopted as metastasis criterion. The detection rates of abdominal esophageal carcinomas and cardiac cancers were 73.5%(144/196) and 83.7% (170/203), respectively. Thoracic lymph node metastasis rate of abdominal esophageal carcinomas was 11.1% (4/36) in 7 area, 27.8% (10/36) in 8 area, 8.3% (3/36) in 9 area, while celiac lymph node metastasis rate was 36.1% (13/36 ) in No.7 group, 19.4% (7/36) in No.1 group, and 11.1% (4/36) in No.2 group primarily. Lymph node metastasis rate of cardiac cancers was 17.9% (5/28) in No.1 group, 28.6% (8/28) in No.2 group, 39.3% (11/28 ) in No.3 group, and 25.0% (7/28) in No.4 group for the first stop lymph nodes, and 35.7% (10/28 ) in No.7 group for the second stop primarily. ConclusionAs metastasis criterion, short diameter ≥10 mm of lymph node at CT is feasible, but there exist certain falsepositive rate. Thoracic lymph node metastasis of abdominal esophageal carcinomas is mainly in the 7, 8, and 9 area, while celiac metastasis is mainly in No.7, No.1, and No.2 groups. Lymph node metastasis of cardiac cancers is in No.1, No.2, No.3, No.4, and No.7 group primarily.
Objective To evaluate the accuracy of the related parameters measured by spinal virtual surgery system (SVSS) three-dimensional (3D) techniques by comparing with the parameters measured by multi-spiral CT (MSCT) workstation. Methods Seven vertebrae specimens of adult men were scanned with MSCT, and the messages were sent toMSCT workstation and SVSS. The 3D image of spine was reconstructed by using volume rendering and multi-planar reformation; based on the parameter requirement of lower cervical pedicle fixation, 10 related parameters were measured. Then SPSS11.0 analyzer software was used to analyze the parameters measured by 2 systems. Between June 2009 and March 2010, 6 patients who received screw insertion in lower cervical spines were given MSCT scanning, then the messages were sent to SVSS 3D reconstruction to evaluate the situation and to collect the parameters of pedicle screw insertion. Results SVSS measurement showed that 1 pedicle was clausura (C3) and the diameters of 4 pedicles in coronal view were lee than 3 mm (C4 in 1, C5 in 2, C6 in 1), which did not fit for screw insertion; the results were similar to those by MSCT measurement. A total of 66 lower cervical pedicle were measured successfully. Significant differences were found in 14 parameters as follows between 2 systems (P lt; 0.05): the left pedicle height of C3, the both sides pedicle width of C4, the right pedicle spongy width of C4, the left X-direction entrance of C6, the both sides Y-direction entrance of C3, total pedicle length of sagittal view in both sides pedicle of C3 and the left pedicle of C5, total pedicle length of axial view in C3 pedicles, the left pedicle of C5, and the right pedicle of C6. There was no significantdifference in the other parameters (P gt; 0.05). In 6 cl inical cases, 34 screws were inserted, the postoperative MSCT scanning showed that 30 screws were placed successfully. The rate of accuracy was 88.24%. According to the Richter’s perforation classification, perforation at grade I and at grade II occurred in 2 cases (5.88%), respectively. Conclusion The accuracy of the parameters measured by SVSS is similar to that by MSCT.