Exoskeleton nursing robot is a typical human-machine co-drive system. To full play the subjective control and action orientation of human, it is necessary to comprehensively analyze exoskeleton wearer’s surface electromyography (EMG) in the process of moving patients, especially identifying the spatial distribution and internal relationship of the EMG information. Aiming at the location of electrodes and internal relation between EMG channels, the complex muscle system at the upper limb was abstracted as a muscle functional network. Firstly, the correlation characteristics were analyzed among EMG channels of the upper limb using the mutual information method, so that the muscle function network was established. Secondly, by calculating the characteristic index of network node, the features of muscle function network were analyzed for different movements. Finally, the node contraction method was applied to determine the key muscle group that reflected the intention of wearer’s movement, and the characteristics of muscle function network were analyzed in each stage of moving patients. Experimental results showed that the location of the myoelectric collection could be determined quickly and efficiently, and also various stages of the moving process could effectively be distinguished using the muscle functional network with the key muscle groups. This study provides new ideas and methods to decode the relationship between neural controls of upper limb and physical motion.
The functional coupling between motor cortex and effector muscles during autonomic movement can be quantified by calculating the coupling between electroencephalogram (EEG) signal and surface electromyography (sEMG) signal. The maximal information coefficient (MIC) algorithm has been proved to be effective in quantifying the coupling relationship between neural signals, but it also has the problem of time-consuming calculations in actual use. To solve this problem, an improved MIC algorithm was proposed based on the efficient clustering characteristics of K-means ++ algorithm to accurately detect the coupling strength between nonlinear time series. Simulation results showed that the improved MIC algorithm proposed in this paper can capture the coupling relationship between nonlinear time series quickly and accurately under different noise levels. The results of right dorsiflexion experiments in stroke patients showed that the improved method could accurately capture the coupling strength of EEG signal and sEMG signal in the specific frequency band. Compared with the healthy controls, the functional corticomuscular coupling (FCMC) in beta (14~30 Hz) and gamma band (31~45 Hz) were significantly weaker in stroke patients, and the beta-band MIC values were positively correlated with the Fugl-Meyers assessment (FMA) scale scores. The method proposed in this study is hopeful to be a new method for quantitative assessment of motor function for stroke patients.
The aim of this study was to design a simple, economic, with high Common Mode Rejection Ratio (CMRR), preamplifier and multi-channel masticatory muscle surface electromyography (sEMG) signal acquisition system assisting to diagnose temporomandibular disorders (TMD). We used the USB interface technology in the EMG data with the aid of the windows to operate system and graphical interface. Eight patients with TMD and eight controls were analyzed separately using this system. In this system, we analyzed sEMG by an optional combination of time domain, frequency domain, time-frequency, several spectral analysis, wavelets and other special algorithms under multi-parameter. Multi-channel sEMG System of Masticatory Muscles is a simple, economic system. It has high sensitivity and specificity. The sEMG signals were changed in patients with TMD. The system would pave the way for diagnosis TMD and help us to assess the treatment effect. A novel and objective method is provided for diagnosis and treatment of oral-maxillofacial disease and functional reconstruction.
In this study, surface electromyography (sEMG) of the lower limbs of cerebral-palsy (CP) subjects in gait cycle was recorded and its parameters of gait cycle characters were analyzed to assess their clinical severity. Three algorithms, including integrated profile (IP), sample-entropy (SampEN) and smooth nonlinear energy operator (SNEO) algorithm, were applied to calculate the duration of walking sEMG segments in simulated SEMG signals. After that, the efficiency and accuracy were compared among these three algorithms. SNEO was then selected as the optimal algorithm among the three algorithms and employed for real sEMG signal processing of CP subjects. The results indicated that there was no significant difference in the accuracy of sEMG segement detection for the three algorithms. However, the computation speed of SNEO algorithm was much faster than those of the others and thus it was a suitable algorithm for detecting walking sEMG segments of CP subjects. In addition, the positive correlation was found between the clinical severity and the mean duration of walking sEMG segments in CP subjects. The results indicated that there was a significant difference in the three groups of CP subjects with different levels of severity. Our findings showed that the mean duration of walking sEMG segments could be considered as an assistant index to evaluate the clinical severity of CP subjects.
The real physical image of the affected limb, which is difficult to move in the traditional mirror training, can be realized easily by the rehabilitation robots. During this training, the affected limb is often in a passive state. However, with the gradual recovery of the movement ability, active mirror training becomes a better choice. Consequently, this paper took the self-developed shoulder joint rehabilitation robot with an adjustable structure as an experimental platform, and proposed a mirror training system completed by next four parts. First, the motion trajectory of the healthy limb was obtained by the Inertial Measurement Units (IMU). Then the variable universe fuzzy adaptive proportion differentiation (PD) control was adopted for inner loop, meanwhile, the muscle strength of the affected limb was estimated by the surface electromyography (sEMG). The compensation force for an assisted limb of outer loop was calculated. According to the experimental results, the control system can provide real-time assistance compensation according to the recovery of the affected limb, fully exert the training initiative of the affected limb, and make the affected limb achieve better rehabilitation training effect.
Surface electromyography (sEMG) has been widely used in the study of clinical medicine, rehabilitation medicine, sports, etc., and its endpoints should be detected accurately before analyzing. However, endpoint detection is vulnerable to electrocardiogram (ECG) interference when the sEMG recorders are placed near the heart. In this paper, an endpoint-detection algorithm which is insensitive to ECG interference is proposed. In the algorithm, endpoints of sEMG are detected based on the short-time energy and short-time zero-crossing rates of sEMG. The thresholds of short-time energy and short-time zero-crossing rate are set according to the statistical difference of short-time zero-crossing rate between sEMG and ECG, and the statistical difference of short-time energy between sEMG and the background noise. Experiment results on the sEMG of rectus abdominis muscle demonstrate that the algorithm detects the endpoints of the sEMG with a high accuracy rate of 95.6%.
Exercise-induced muscle fatigue is a phenomenon that the maximum voluntary contraction force or power output of muscle is temporarily reduced due to muscular movement. If the fatigue is not treated properly, it will bring about a severe injury to the human body. With multi-channel collection of lower limb surface electromyography signals, this article analyzes the muscle fatigue by adoption of band spectrum entropy method which combined electromyographic signal spectral analysis and nonlinear dynamics. The experimental result indicated that with the increase of muscle fatigue, muscle signal spectrum began to move to low frequency, the energy concentrated, the system complexity came down, and the band spectrum entropy which reflected the complexity was also reduced. By monitoring the entropy, we can measure the degree of muscle fatigue, and provide an indicator to judge fatigue degree for the sports training and clinical rehabilitation training.
To quantitatively evaluate the upper-limb spasticity of stroke patients in recovery stage, the relationship between surface electromyography (sEMG) characteristic indexes from biceps brachii and triceps brachii and the spasticity were explored, which provides the electrophysiological basis for clinical rehabilitation. Ten patients with spasticity after stroke were selected to be estimated by modified Ashworth (MAS) assessment and a passive elbow sinusoidal motion experiment was carried out. At the same time, the sEMG of biceps and triceps were recorded. The results shows that the reflex electromyographic threshold could reflect the physiological mechanism of spasticity and had significant correlation with MAS scale which showed that sEMG could be prosperous for the clinical quantitative evaluation of spasticity of stroke patients.
Surface electromyogram (sEMG) may have low signal to noise ratios. An adaptive wavelet thresholding technique was developed in this study to remove noise contamination from sEMG signals. Compared with conventional wavelet thresholding methods, the adaptive approach can adjust thresholds based on different signal to noise ratios of the processed signal, thus effectively removing noise contamination and reducing distortion of the EMG signal. The advantage of the developed adaptive thresholding method was demonstrated using simulated and experimental sEMG recordings.
Wearing transfemoral prosthesis is the only way to complete daily physical activity for amputees. Motion pattern recognition is important for the control of prosthesis, especially in the recognizing swing phase and stance phase. In this paper, it is reported that surface electromyography (sEMG) signal is used in swing and stance phase recognition. sEMG signal of related muscles was sampled by Infiniti of a Canadian company. The sEMG signal was then filtered by weighted filtering window and analyzed by height permitted window. The starting time of stance phase and swing phase is determined through analyzing special muscles. The sEMG signal of rectus femoris was used in stance phase recognition and sEMG signal of tibialis anterior is used in swing phase recognition. In a certain tolerating range, the double windows theory, including weighted filtering window and height permitted window, can reach a high accuracy rate. Through experiments, the real walking consciousness of the people was reflected by sEMG signal of related muscles. Using related muscles to recognize swing and stance phase is reachable. The theory used in this paper is useful for analyzing sEMG signal and actual prosthesis control.