west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "titanium" 34 results
  • Biomechanical study on wing shaped titanium plate fixation of acetabular anterior column and posterior hemi-transverse fracture under multiple working conditions

    This article aims to compare and analyze the biomechanical differences between wing-shaped titanium plates and traditional titanium plates in fixing acetabular anterior column and posterior hemi-transverse (ACPHT) fracture under multiple working conditions using the finite element method. Firstly, four sets of internal fixation models for acetabular ACPHT fractures were established, and the hip joint stress under standing, sitting, forward extension, and abduction conditions was calculated through analysis software. Then, the stress of screws and titanium plates, as well as the stress and displacement of the fracture end face, were analyzed. Research has found that when using wing-shaped titanium plates to fix acetabular ACPHT fractures, the peak stress of screws decreases under all working conditions, while the peak stress of wing-shaped titanium plates decreases under standing and sitting conditions and increases under forward and outward extension conditions. The relative displacement and mean stress of the fracture end face decrease under all working conditions, but the values are higher under forward and outward extension conditions. Wing-shaped titanium plates can reduce the probability of screw fatigue failure when fixing acetabular ACPHT fractures and can bear greater loads under forward and outward extension conditions, improving the mechanical stability of the pelvis. Moreover, the stress on the fracture end surface is more conducive to stimulating fracture healing and promoting bone tissue growth. However, premature forward and outward extension rehabilitation exercises should not be performed.

    Release date:2025-04-24 04:31 Export PDF Favorites Scan
  • Autologous ilium graft combination with titanium plate for sternal reconstruction: A case report

    The sternum is the pivotal component of the thoracic cavity. It is connected with the clavicle and ribs on the upper part and both sides respectively, and plays an important role in protecting the stability of the chest wall. Sternal resection usually results in a large segmental chest wall defect that causes the chest wall to float and requires sternal reconstruction. This paper reports a 62 years male patient with thymic squamous cell carcinoma with sternal metastasis, who underwent thymotomy, sternal tumor resection and autologous lilum graft combined with sternal reconstruction by titanium plate after relevant examination was completed and surgical contraindications were eliminated. The patient was followed up for 6 months, the respiratory and motor functions were normal and the thoracic appearance was good.

    Release date:2024-02-20 03:09 Export PDF Favorites Scan
  • Preparation of Ti-O Film Deposited on the Surface of a New Type of Artificial Mechanical Heart Valve

    The rutile structure titanium oxide (Ti-O) film was prepared on the pure titanium material TA2 (99.999%) surface by the magnetic filter high vacuum arc deposition sputtering source. The method can not only maintain the material mechanical properties, but also improve the surface properties for better biocompatibility to accommodate the physiological environment. The preparation process of the Ti-O film was as follows. Firstly, argon ions sputtered to the TA2 substrate surface to remove the excess impurities. Secondly, a metal ion source generated Ti ions and oxygen ions by the RF discharge. Meanwhile a certain negative bias was imposed on the sample. There a certain composition of Ti-O film was obtained under a certain pressure of oxygen in the vacuum chamber. Finally, X-ray diffraction was used to research the structure and composition of the film. The results showed that the Ti-O film of the rutile crystal structure was formed under the 0.18 Pa oxygen partial pressure. A Nano scratch experiment was used to test the coating adhesion property, which demonstrated that the film was stable and durable. The contact angle experiment and the platelet clotting experiment proved that the modified surface method had improved platelet adhesion performance, and, therefore, the material possessed better biocompatibility. On the whole, the evaluations proved the modified material had excellent performance.

    Release date: Export PDF Favorites Scan
  • THE ROLE OF FETUS DECALCIFIED BONE MATRIX (FDBM) IN INDUCING PURE TITANIUMBONG IMPLANT INTERGRATION

    Because of its high biological compatibility, titanium has been a good biomaterial. The implanted artificial bone made from titanium can contact with the vital and mature osseous tissue directly within 3-6 months, the so-called osteointergration. In order to promote the process of osteointergration, FDBM of rabbit was prepared and was combined with pure titanium so as to speed up osteointergration. The study focused on bone density, bone intergration rate, new bone growth rate around the pure titanium, and the Ca2+ and PO(4)3- density of titanium-bone interface. A control group of pure titanium inplant without FDBM was set up. The results showed FDBM had no antigenicity. It could induce and speed up the new bone formation at titanium-bone interface. The titanium-bone intergration time was within 2 months. It was suggested that there were more bone morphogenesis protein (BMP) or other bone induction and bone formation factors in brephobone than that in child and adult bone. As a kind of bone induction material, FDBM was easy prepared, cheap in price, easy to storage, no antigenicity and obvious bone-inductive function.

    Release date:2016-09-01 11:07 Export PDF Favorites Scan
  • CLINICAL STUDY ON ZYGOMATIC SPINDLE-SHAPED OSTEOTOMY AND INTERNAL PUSH OF TITANIUM SCREW ANCHOR IN TREATMENT OF PROMINENT MALAR

    ObjectiveTo explore the effectiveness of the zygomatic spindle-shaped osteotomy and internal push of titanium screw anchor for prominent malar. MethodBetween July 2011 and January 2015, 58 patients with prominent malar underwent zygomatic spindle-shaped osteotomy and internal push of titanium screw anchor. There were 3 males and 55 females, aged 18-33 years (mean, 23 years). They had congenital bilateral prominent malar. Preoperative anteroposterior, lateral, supine position, 45°oblique photographs of the face were taken, three-dimensional CT reconstruction of face was performed. Simple prominent malar was observed in 30 cases, and prominent malar and zygomatic arch in 28 cases; zygomatic bone and zygomatic arch were symmetrical in 51 cases, and asymmetrical in 7 cases. ResultsAll patients obtained stage I incision healing after operation, without infection or hematoma. Numbness of the upper lip occurred in 2 cases, limitation of mouth opening in 1 case, and nasolabial fold deepening in 1 case, which recovered spontaneously after 3 months. Fifty-eight cases were followed up 6-12 months (mean, 10 months). Zygomatic narrow spacing was 10.6-13.9 mm (mean, 11.2 mm). No ptosis of facial soft tissue, zygomatic step, facial nerve injury, raising eyebrow, dysfunction of eyes closure, or temporomandibular joint disorder syndrome occurred. Good bone healing was obtained, zygomatic facial sensation had no obvious abnormality, all patients were satisfied with the improvement of appearance. ConclusionsZygomatic spindle-shaped osteotomy and internal push titanium screw anchor can effectively reduce the cheekbones, and maintain the natural curve of zygomatic body and zygomatic arch. Because of simple operation, less complications, and excellent results, it is an ideal plasty.

    Release date: Export PDF Favorites Scan
  • Application of nickel-titanium shape memory staples in treatment of multiple metatarsal fractures

    Objective To investigate the effectiveness of nickel-titanium shape memory staples in treating multiple metatarsal fractures. MethodsThe clinical data of 27 patients with multiple metatarsal fractures who were treated between January 2022 and June 2023 and met the selection criteria were retrospectively analysed. The cohort consisted of 16 males and 11 females, aged 33-65 years (mean, 47.44 years). The causes of injury included heavy object impact in 11 cases, traffic accidents in 9 cases, and crush in 7 cases. Simultaneous fractures of 2, 3, 4, and 5 bones occurred in 6, 6, 4, and 8 cases, respectively, with tarsometatarsal joint injury in 3 cases. Fixation was performed using staples for 16, 22, and 9 fractures in the metatarsal neck, shaft, and the base, respectively, and 5 tarsometatarsal joint injuries. Preoperative soft tissue injuries were identified in 8 cases and classified according to the Tscherne-Oestern closed soft tissue injury classification as type Ⅰ in 5 cases and type Ⅱ in 3 cases. One case of type Ⅱexhibited preoperative skin necrosis. The patients were treated with fixation using nickel-titanium shape memory staples. Complications and fracture healing were documented. At last follow-up, the American Orthopaedic Foot and Ankle Society (AOFAS) forefoot score was used to evaluate the function, and the visual analogue scale (VAS) score was used to evaluate the pain. Results The 27 patients were followed up 9-19 months (mean, 12.4 months). Postoperative X-ray films revealed no loss of fracture reduction, and all fractures achieved bony union. No internal fixator loosening, breakage, or other mechanical failures was observed. The mean fracture healing time was 3.13 months (range, 3-4 months). Postoperatively, 4 cases (2 of Tscherne-Oestern type Ⅰ, 2 of type Ⅱ) developed superficial skin necrosis, which resolved with dressing changes. No infection was observed in the remaining patients, and all wounds healed. At last follow-up, the AOFAS forefoot score ranged from 70 to 95, with an average of 86.6, of which 19 cases were excellent, 6 cases were good, and 2 cases were fair, with an excellent and good rate of 92.6%; the VAS score ranged from 0 to 3, with an average of 0.9, of which 24 cases were excellent, and 3 cases were good, with an excellent and good rate of 100%. Conclusion The use of nickel-titanium shape memory staples in the treatment of multiple metatarsal fractures can effectively protect local skin and soft tissues and minimize secondary damage associated with internal fixator insertion. It is a viable surgical option for management of multiple metatarsal fractures.

    Release date:2025-02-17 08:55 Export PDF Favorites Scan
  • LONG-SEGMENTAL TRACHEA REPLACEMENT USING NICKEL-TITANIUM ALLOY STENT WRAPPED WITH AUTOLOGOUS PERICARDIUM

    ObjectiveTo perfect the surgical process that trachea could be reconstructed by nickel-titanium (Ni-Ti) alloy stent wrapped with autologous pericardium, and to evaluate the effectiveness and observe the complications. MethodsIn the experiment, twelve healthy Bama suckling pigs with weight of 18-25 kg were selected. The pericardium was harvested to cover the Ni-Ti alloy stent. The compound artificial trachea was used to reconstruct long-segmental (6 cm) trachea defect. The effectiveness, complications, the properties, and growth rate of the new mucosa of the artificial trachea lumen were observed. ResultsOf 12 pigs, 2 died soon because of hemorrhage and infection, respectively; 7 died at 2-4 months after operation because of hyperplasia at the middle section and blockage of phlegm plug; 3 survived after 42 weeks postoperatively, but accompanied with dyspnea symptom. At 1, 2, 3, 4, and 5 months after operation, the average crawl length of the new trachea mucosa was 1, 3, 5, 7, and 10 mm, respectively; the occurrence rates of anastomotic stenosis were 0 (0/10), 0 (0/9), 0 (0/4), 33.3% (1/3), and 33.3% (1/3) respectively; and the occurrence rates of scar hyperplasia in the middle of lumen were 20% (2/10), 66.7% (6/9), 75.0% (3/4), 66.7% (2/3), and 100% (3/3), respectively. At 7 months postoperatively, the bronchoscopy examination showed that the scar in central part of artificial trachea had the trends of stagnation, softening, and narrowing, and respiratory symptom had the trend of slight ease. Hyperplasia tissue could be found in central part of artificial trachea by autopsy and was verified to be fiber cells and necrotic tissue by pathology examination. ConclusionNi-Ti alloy stent with autologous pericardium can insure that the reconstructed tracheal lumen is unobstructed, and support the trachea epithelium regeneration; the main factors of the death of the experimental animals are the lumen hyperplasia of the artificial trachea and the blockage of the secondary phlegm plug.

    Release date: Export PDF Favorites Scan
  • EFFECTIVENESS OF U-SHAPE TITANIUM SCREW-ROD FIXATION SYSTEM WITH BONE AUTOGRAFTING FOR LUMBAR SPONDYLOLYSIS OF YOUNG ADULTS

    ObjectiveTo investigate the effectiveness of U-shape titanium screw-rod fixation system with bone autografting for lumbar spondylolysis of young adults. MethodsBetween January 2008 and December 2011, 32 patients with lumbar spondylolysis underwent U-shape titanium screw-rod fixation system with bone autografting. All patients were male with an average age of 22 years (range, 19-32 years). The disease duration ranged from 3 to 24 months (mean, 14 months). L3 was involved in spondylolysis in 2 cases, L4 in 10 cases, and L5 in 20 cases. The preoperative visual analogue scale (VAS) and Oswestry disability index (ODI) scores were 8.0±1.1 and 75.3±11.2, respectively. ResultsThe operation time was 80-120 minutes (mean, 85 minutes), and the blood loss was 150-250 mL (mean, 210 mL). Primary healing of incision was obtained in all patients without complications of infection and nerve symptom. Thirty-two patients were followed up 12-24 months (mean, 14 months). Low back pain was significantly alleviated after operation. The VAS and ODI scores at 3 months after operation were 1.0±0.5 and 17.6±3.4, respectively, showing significant differences when compared with preoperative ones (t=30.523,P=0.000;t=45.312,P=0.000). X-ray films and CT showed bone fusion in the area of isthmus defects, with the bone fusion time of 6-12 months (mean, 9 months). During follow-up, no secondary lumbar spondyloly, adjacent segment degeneration, or loosening or breaking of internal fixator was found. ConclusionThe U-shape titanium screw-rod fixation system with bone autografting is a reliable treatment for lumbar spondylolysis of young adults because of a high fusion rate, minimal invasive, and maximum retention of lumbar range of motion.

    Release date: Export PDF Favorites Scan
  • Biomechanical comparison of three kinds of fixation instruments for calcaneal osteotomy

    ObjectiveTo compare the biomechanical characteristics of self-made nickel-titanium shape memory alloy stepped plate with calcaneal plate and cannulated compression screws in fixing calcaneal osteotomy.MethodsCalcaneal osteotomy was operated on 6 fresh-frozen lower limbs collected from donors. Then three kinds of fixation materials were applied in random, including the self-made nickel-titanium shape memory alloy stepped plate (group A), calcaneal plate (group B), and cannulated compression screws (group C). Immediately after fixation, axial loading of 20-600 N and 20 N/s in speed was introduced to record the biomechanical data including maximum displacement, elastic displacement, and maximum load. Then fatigue test was performed (5 Hz in frequency and repeat 3 000 times) and the same axial loading was introduced to collect the biomechanical data. Finally, the axial compression stiffness before and after fatigue test were calculated.ResultsThere was no significant difference in the axial compression stiffness between pre- and post-fatigue test in each group (P>0.05). However, the axial compression stiffness was significant higher in group A than that in groups B and C both before and after fatigue test (P<0.05). No significant difference was found between group B and group C (P>0.05).ConclusionSelf-made nickel-titanium shape memory alloy stepped plate is better than calcaneal plate and cannulated compression screws in axial load stiffness after being used to fix calcaneal osteotomy.

    Release date:2018-02-07 03:21 Export PDF Favorites Scan
  • Effect of modified titanium loaded with endothelial progenitor cells-exosomes on osteogenic and angiogenic differentiations of adipose-derived stem cells

    Objective To investigate the effects of titanium modified by ultrasonic acid etching/anodic oxidation (UAT) loaded with endothelial progenitor cells-exosome (EPCs-exo) on proliferation and osteogenic and angiogenic differentiations of adipose-derived stem cells (ADSCs). Methods The adipose tissue and bone marrow of 10 Sprague Dawley rats were harvested. Then the ADSCs and EPCs were isolated and cultured by collagenase digestion method and density gradient centrifugation method, respectively, and identified by flow cytometry. Exo was extracted from the 3rd to 5th generation EPCs using extraction kit, and CD9 and CD81 were detected by Western blot for identification. The three-dimensional printed titanium was modified by ultrasonic acid etching and anodic oxidation to prepare the UAT. The surface characteristics of UAT before and after modification was observed by scanning electron microscopy; UAT was placed in EPCs-exo solutions of different concentrations (100, 200 ng/mL), and the in vitro absorption and release capacity of EPCs-exo was detected by BCA method. Then, UAT was placed in DMEM medium containing different concentrations of EPCs-exo (0, 100, 200 ng/mL), and co-cultured with the 3rd generation ADSCs to construct UAT-ADSCs-exo. Cell morphology by laser confocal microscopy, live/dead cell staining, and cell proliferation were observed to evaluate biocompatibility; alkaline phosphatase (ALP) staining and alizarin red staining, RT-PCR detection of osteogenesis-related genes [osteocalcin (OCN), RUNT-related transcription factor 2 (Runx2), ALP, collagen type 1 (COL-1)] and angiogenesis-related gene [vascular endothelial growth factor (VEGF)], immunofluorescence staining for osteogenesis (OCN)- and angiogenesis (VEGF)-related protein expression were detected to evaluate the effect on the osteogenic and angiogenic differentiation ability of ADSCs. Results Scanning electron microscopy showed that micro-nano multilevel composite structures were formed on the surface of UAT. About 77% EPCs-exo was absorbed by UAT within 48 hours, while EPCs-exo absorbed on the surface of UAT showed continuous and stable release within 8 days. The absorption and release amount of 200 ng/mL group were significantly higher than those of 100 ng/mL group (P<0.05). Biocompatibility test showed that the cells in all concentration groups grew well after culture, and the 200 ng/mL group was better than the other groups, with fully spread cells and abundant pseudopodia, and the cell count and cell activity were significantly higher than those in the other groups (P<0.05). Compared with the other groups, 200 ng/mL group showed enhanced ALP activity and mineralization ability, increased expressions of osteogenic and angiogenic genes (OCN, Runx2, COL-1, ALP, and VEGF), as well as increased expressions of OCN and VEGF proteins, with significant differences (P<0.05). Conclusion EPCs-exo can effectively promote the adhesion, proliferation, and osteogenic and angiogenic differentiation of ADSCs on UAT surface, the effect is the most significant when the concentration is 200 ng/mL.

    Release date:2022-08-29 02:38 Export PDF Favorites Scan
4 pages Previous 1 2 3 4 Next

Format

Content