ObjectiveTo investigate the clinical value of 3D CT combined with CT-guided Hookwire for localizing small pulmonary nodules in thoracoscopic pulmonary segmentectomy.MethodsFrom December 2017 to February 2019, 39 patients received thoracoscopic pulmonary segmentectomy in our hospital, including 14 males and 25 females with a mean age of 51.33±11.17 years. Before operation, we used Mimics Medical 20.0 to re-establish the anatomy of lung and locate the small pulmonary nodules with Hookwire guided by CT. Based on the position of Hookwire needle, 3D CT images and simulated surgical methods, thoracoscopic pulmonary segmentectomy was performed accurately.ResultsThe surgery was successfully completed in 39 patients without a transfer to open procedure. The mean operation time, mean intraoperative blood loss, mean postoperative hospital stay, mean thoracic tube drainage time were 148.97±28.56 min, 27.95±17.57 mL, 6.95±1.68 d, 4.21±1.95 d, respectively. Postoperative complications occurred in 5 patients (12.82%), including atrial fibrillation in 1, pulmonary infection in 1, chylothorax in 1, intrathoracic hemorrhage in 1 and pneumothorax in 1. All actual surgical margins were larger than 3.0 cm.ConclusionThe application of preoperative 3D CT combined with CT-guided Hookwire to localize small pulmonary nodules is helpful for accurate anatomical segmental resection of the lung, making the operation safe .
ObjectiveTo study the feasibility and safety of CT-guided preoperative Hookwire localization of pulmonary nodules in clinical application.MethodsClinical data of 102 patients who were scheduled to undergo surgical treatment for pulmonary nodules from June 2015 to April 2020 in the North Ward of Thoracic Surgery Department of Ruijin Hospital were retrospectively analyzed. There were 38 males and 64 females, aged 23-82 (53.2±12.8) years.ResultsAll 102 patients with pulmonary nodules underwent CT-guided preoperative Hookwire localization successfully, with a localization success rate of 100.0%. The localization time was 27.0 (11-67) min; the number of times to adjust the angle during the positioning process was 6.9 (3-14); the needle depth of the positioning needle was 41.5 (16.3-69.1) mm. A total of 48 (47.1%) patients had a small amount of bleeding in the lung tissue in the positioning area after positioning; 53 (51.9%) patients had a small amount of pneumothorax after positioning; 16 (15.7%) patients were found that the positioning needle completely shedded from the lung tissue in the subsequent surgery. One patient was transferred to open thoracotomy because of extensive dense adhesion in the thorax, and the remaining 101 patients were operated on under thoracoscopy. Postoperative pathology showed that 5 (4.9%) patients were adenocarcinoma in situ, 28 (27.5%) were microinvasive adenocarcinoma, 36 (35.3%) patients were invasive carcinoma and 32 (31.3%) patients were benign lesions. No patients had complications or adverse events related to preoperative positioning.ConclusionPreoperative CT-guided localization of Hookwire intrapulmonary nodules is safe and effective, and can meet the intraoperative localization needs of thoracic surgeons in most clinical situations, and is not inferior to other preoperative localization methods currently used in clinics.
ObjectiveTo systematically evaluate the application effect of CT-guided Hook-wire localization and CT-guided microcoil localization in pulmonary nodules surgery. MethodsThe literatures on the comparison between CT-guided Hook-wire localization and CT-guided microcoil localization for pulmonary nodules were searched in PubMed, EMbase, The Cochrane Library, Web of Science, Wanfang, VIP and CNKI databases from the inception to October 2021. Review Manager (version 5.4) software was used for meta-analysis. The Newcastle-Ottawa Scale (NOS) was used to evaluate the quality of studies.ResultsA total of 10 retrospective cohort studies were included, with 1 117 patients including 473 patients in the CT-guided Hook-wire localization group and 644 patients in the CT-guided microcoil localization group. The quality of the studies was high with NOS scores>6 points. The result of meta-analysis showed that the difference in the localization operation time (MD=0.14, 95%CI −3.43 to 3.71, P=0.940) between the two groups was not statistically significant. However, the localization success rate of the Hook-wire group was superior to the microcoil group (OR=0.35, 95%CI 0.17 to 0.72, P=0.005). In addition, in comparison with Hook-wire localization, the microcoil localization could reduce the dislocation rate (OR=4.33, 95%CI 2.07 to 9.08, P<0.001), the incidence of pneumothorax (OR=1.62, 95%CI 1.12 to 2.33, P=0.010) and pulmonary hemorrhage (OR=1.64, 95%CI 1.07 to 2.51, P=0.020). ConclusionAlthough Hook-wire localization is slightly better than microcoil localization in the aspect of the success rate of pulmonary nodule localization, microcoil localization has an obvious advantage compared with Hook-wire localization in terms of controlling the incidence of dislocation, pneumothorax and pulmonary hemorrhage. Therefore, from a comprehensive perspective, this study believes that CT-guided microcoil localization is a preoperative localization method worthy of further promotion.
Objective To investigate the curative effects of open reduction and internal fixation with Kirschner wire for Mason type-II radial head or neck fracture in children. Methods From September 2007 to June 2009, 17 cases of Mason type-II radial head or neck fracture were treated, including 11 males and 6 femals with an average age of 8.5 years (4-11 years).The locations were left side in 5 cases and right side in 12 cases. All fractures were caused by fall ing and classified as Mason type- II fracture. Two cases compl icated by radial nerve deep branch injury. The time from injury to operation was 4 hours to 5 days. All cases received open reduction and internal fixation with Kirschner wire. They were evaluated by anteroposterior and lateral radiographs and functionally by Broberg criteria. Results Wound healed primarily in all patients. According to Métaizeau criteria, the results were excellent in 15 patients and good in 2 patients, who achieved anatomical reduction. Seventeen patients were followed up for a mean time of 14 months (6-25 months). Function returned to normal in 2 cases compl icated by radial nerve deep branch injury after 6 months of operation. No compl ications of infection and nerve injury occurred. The X-ray films showed that bony heal ing was achieved in all cases; the heall ing time was 2.0-3.5 months (mean 3 months). According to Broberg criteria, the outcome was excellent in 11 cases, good in 4 cases, and fair in 2 cases, the excellent and good rate was 88.2%. Conclusion Open reduction and internal fixation with Kirschner wire has good effect, satisfactory functional recovery and less compl ication in the treatment of Mason type-II fracture of radial head or neck in children.
Objective To compare the results of plate and Kirschner wire fixation in treatment of nonunion of clavicular fracture. Methods From September 1991 to January 2002, 19 patients (9 with plate and 10 with Kirschner wire) were treated. The results were evaluated by reduction, bone union time, recovery of joint function, pain, and correction of deformation. Results The follow-up time was 6-23 months with an average of 11 months. Bone union -occurred after a mean time of 11 weeks. In plate group, 7 patients gained excellent results, 1 good and1 fair. In Kirschner wire group, 3 patients gained excellent results, 3 good, 3 fair and 1 poor. The result of plate is significantly better than that of Kirschner wire fixation(Plt;0.05). Conclusion Plate fixation is a good simple method for treatment of nonunion of clavicular fracture.
Objective To investigate the effectiveness of arthroscopy-assisted combined fixation of Kirschner wire and external fixator for treating extreme distal radial fractures. Methods Between January 2014 and May 2016, 21 patients who suffered from extreme distal radial fractures were treated by arthroscopy-assisted combined fixation of Kirschner wire and external fixator. There were 14 males and 7 females with an age of 32-57 years (mean, 42.3 years). The causes of injury included falling in 13 cases and traffic accident in 8 cases. The fracture type included 8 cases of type 23C1, 9 cases of type 23C2, and 4 cases of type 23C3 according to AO/OTA classification. The time from injury to operation was 3-7 days (mean, 4.4 days). The Mayo score and disability of arm, shoulder, and hand (DASH) score were used to assess the pain and function of the wrist joint. Results There was no needle red swelling, tendon irritation, or orther early complications. All the patients were followed up 10-35 months (mean, 18.3 months). The fracture healing time was 9-13 weeks (mean, 10.6 weeks). At last follow-up, the Mayo score was 87-94 (mean, 90.9); and 17 cases were excellent and 4 were good. The DASH score was 7-13 (mean, 10.6). Conclusion Arthroscopy-assisted combined fixation of Kirschner wire and external fixator for treating extreme distal radial fractures has the advantages of firm fixation, early functional exercise, less postoperative complications, and good functional recovery of wrist joint.
From August 1986 to October 1990, 34 cases of fractures of patella were treated by the self-designed spring Kirschner wire, in which, 25 cases were followed up for an average of 1.5 years. The excellentgood rate reached 88%. In comparing with the traditional method of treatment, it gave more secure fixation for fracture, without the need or only a short time of immobilization needed, short treatment course and satisfactory return of function.
ObjectiveTo investigate the effectiveness of Endobutton plate coracoclavicular fixation combined with fracture site high-strength suture Nice knot cerclage fixation in the treatment of distal clavicle fracture with coracoclavicular ligament injury. Methods The clinical data of 33 cases of distal clavicular fracture with coracoclavicular ligament injury treated by Endobutton coracoclavicular plate fixation between January 2017 and December 2020 were analyzed retrospectively. According to the fixation methods of fracture site, they were divided into two groups: the high-strength suture Nice knot fixation group (study group, 16 cases) and the transacromial Kirschner wire fixation group (control group, 17 cases). There was no significant difference between the two groups in common data such as age, gender, injury side, cause of injury, Craig type, combined injury, time from injury to operation, and preoperative visual analogue scale (VAS) score and Constant-Murley score (P>0.05). Postoperative fracture healing and complications were observed, and the increase rate of coracoclavicular space on the affected side was calculated at last follow-up. VAS score was used to evaluate shoulder pain before operation, at 1 week, 1 month, 3 months after operation, and at last follow-up. The shoulder function was evaluated according to Constant-Murley shoulder score before operation, at 1 month, 3 months after operation, and at last follow-up. Results The operations were successfully completed in both groups without severe complications such as vascular nerve injury and coracoid fracture. In the control group, 1 case (5.9%) had slight pin tract infection and 1 case (5.9%) had Kirschner wire displacement; there was no obvious complication in the study group. The patients in both groups were followed up 9-36 months (mean, 22.9 months). The fracture healing time of the study group and the control group were (12.56±0.73) weeks and (13.59±0.87) weeks, respectively, and the difference was significant (t=−3.661, P=0.001). At last follow-up, the increase rates of coracoclavicular space on the affected side of the study group and the control group were 8.88%±1.19% and 8.55%±1.07%, respectively, showing no significant difference (t=0.837, P=0.409). The postoperative VAS score and Constant-Murley score of the two groups significantly improved when compared with those before operation, and the two scores gradually improved with the extension of time after operation (P<0.05). Except that the VAS score at 1 week and 1 month after operation and the Constant-Murley score at 1 month after operation in the study group were significantly better than those in the control group (P<0.05), there was no significant difference between the two groups at other time points after operation (P>0.05). Conclusion For oblique fracture or combined with butterfly fracture in the distal clavicle fracture with coracoclavicular ligament injury, the fracture site high-strength suture Nice knot fixation is a good supplement to the Endobutton plate coracoclavicular fixation. It can stabilize the fracture end, reduce the complications of Kirschner wire fixation, and is more conducive to fracture healing. The effectiveness is satisfactory.
Objective To compare the effectiveness of suspension fixation plus hinged external fixator with double plate internal fixation in the treatment of type C humeral intercondylar fractures. Methods Between January 2014 and April 2016, 30 patients with type C (Association for the Study of Internal Fixation, AO/ASIF) humeral intercondylar fractures were treated. Kirschner wire suspension fixation plus hinged external fixator was used in 14 cases (group A), and double plate internal fixation in 16 cases (group B). There was no significant difference in gender, age, injury cause, disease duration, injury side, and type of fracture between 2 groups (P>0.05). Results There was no significant difference in operation time and hospitalization stay between 2 groups (P>0.05). But the intraoperative blood loss in group A was significantly less than that in group B (P<0.05); the visual analogue scale (VAS) score at 1 day and 3 days after operation in group A were significantly less than those in group B (P<0.05). Primary healing of incision was obtained in all patients of 2 groups, and no surgery-related complications occurred. The patients were followed up 6-24 months (mean, 12.3 months) in group A and 6-24 months (mean, 12.8 months) in group B. The self-evaluation satisfaction rate was 85.7% (12/14) in group A and was 81.2% (13/16) in group B at 3 months after operation, showing no significant difference (χ2=0.055, P=0.990). Based on the improved Gassebaum elbow performance score at 6 months after operation, excellent and good rate of the elbow function was 78.6% (excellent in 5 cases, good in 6 cases, fair in 2 cases, and poor in 1 case) in group A and was 81.2% (excellent in 6 cases, good in 7 cases, fair in 2 cases, and poor in 1 case) in group B, showing no significant difference between 2 groups (χ2=0.056, P=0.990). Heterotopic ossification occurred at 3 months after operation in 1 case of each group respectively. The X-ray films showed bony union in all cases; no loosening or breakage of screw was observed. The bone union time showed no significant difference between 2 groups (t=–0.028, P=0.978). The time of internal fixation removal, the intraoperative blood loss, and VAS score at 1 day and 3 days after operation in group A were significant better than those in group B (P<0.05). Conclusion The suspension fixation plus hinged external fixator and double plate internal fixation for the treatment of type C humeral intercondylar fractures have ideal outcome in elbow function. But the suspension fixation plus hinged external fixator is better than double plate internal fixation in intraoperative blood loss, postoperative VAS score, and time of internal fixation removal.
Objective To investigate the effectiveness of Kirschner wire combined with silk tension band in the treatment of ulnar collateral ligament avulsion fracture of the thumb metacarpophalangeal joint. Methods Between September 2008 and October 2011, 14 patients with ulnar collateral ligament avulsion fracture of the thumb metacarpophalangeal joint were treated using a combination of Kirschner wire and silk tension band. There were 8 males and 6 females, aged 23-55 years (mean, 40.8 years). The causes of injury were machinery twist injury in 5 cases, manual twist injury in 4 cases, falling in 4 cases, sports injury in 1 case. The time from injury to operation was 2 hours-14 days. All the patients presented pain over the ulnar aspect of the metacarpophalangeal joint of the thumb, limitation of motion, and joint instability with pinch and grip. The lateral stress testing of the metacarpophalangeal joint was positive. Function training was given at 2 weeks after operation. Results All incisions healed by first intention. The lateral stress testing of the metacarpophalangeal joint was negative. All the patients were followed up 6-18 months (mean, 13.1 months). The X-ray films showed good fracture reduction and healing with an average time of 7 weeks (range, 4-10 weeks). At last follow-up, the thumbs had stable flexion and extension of the metacarpophalangeal joint, normal opposition function and grip and pinch strengths. According to Saetta et al. criteria for functional assessment, the results were excellent in 11 cases and good in 3 cases; the excellent and good rate was 100%. Conclusion It is an easy and simple method to treat ulnar collateral ligament avulsion fracture of the thumb metacarpophalangeal joint using Kirschner wire combined with silk tension band, which can meet the good finger function.