west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "wire" 53 results
  • Clinical analysis of CT-guided preoperative Hookwire localization of pulmonary nodules in 102 patients

    ObjectiveTo study the feasibility and safety of CT-guided preoperative Hookwire localization of pulmonary nodules in clinical application.MethodsClinical data of 102 patients who were scheduled to undergo surgical treatment for pulmonary nodules from June 2015 to April 2020 in the North Ward of Thoracic Surgery Department of Ruijin Hospital were retrospectively analyzed. There were 38 males and 64 females, aged 23-82 (53.2±12.8) years.ResultsAll 102 patients with pulmonary nodules underwent CT-guided preoperative Hookwire localization successfully, with a localization success rate of 100.0%. The localization time was 27.0 (11-67) min; the number of times to adjust the angle during the positioning process was 6.9 (3-14); the needle depth of the positioning needle was 41.5 (16.3-69.1) mm. A total of 48 (47.1%) patients had a small amount of bleeding in the lung tissue in the positioning area after positioning; 53 (51.9%) patients had a small amount of pneumothorax after positioning; 16 (15.7%) patients were found that the positioning needle completely shedded from the lung tissue in the subsequent surgery. One patient was transferred to open thoracotomy because of extensive dense adhesion in the thorax, and the remaining 101 patients were operated on under thoracoscopy. Postoperative pathology showed that 5 (4.9%) patients were adenocarcinoma in situ, 28 (27.5%) were microinvasive adenocarcinoma, 36 (35.3%) patients were invasive carcinoma and 32 (31.3%) patients were benign lesions. No patients had complications or adverse events related to preoperative positioning.ConclusionPreoperative CT-guided localization of Hookwire intrapulmonary nodules is safe and effective, and can meet the intraoperative localization needs of thoracic surgeons in most clinical situations, and is not inferior to other preoperative localization methods currently used in clinics.

    Release date:2022-01-21 01:31 Export PDF Favorites Scan
  • CT-guided Hook-wire versus microcoil localization in the pulmonary nodules surgery: A systematic review and meta-analysis

    ObjectiveTo systematically evaluate the application effect of CT-guided Hook-wire localization and CT-guided microcoil localization in pulmonary nodules surgery. MethodsThe literatures on the comparison between CT-guided Hook-wire localization and CT-guided microcoil localization for pulmonary nodules were searched in PubMed, EMbase, The Cochrane Library, Web of Science, Wanfang, VIP and CNKI databases from the inception to October 2021. Review Manager (version 5.4) software was used for meta-analysis. The Newcastle-Ottawa Scale (NOS) was used to evaluate the quality of studies.ResultsA total of 10 retrospective cohort studies were included, with 1 117 patients including 473 patients in the CT-guided Hook-wire localization group and 644 patients in the CT-guided microcoil localization group. The quality of the studies was high with NOS scores>6 points. The result of meta-analysis showed that the difference in the localization operation time (MD=0.14, 95%CI −3.43 to 3.71, P=0.940) between the two groups was not statistically significant. However, the localization success rate of the Hook-wire group was superior to the microcoil group (OR=0.35, 95%CI 0.17 to 0.72, P=0.005). In addition, in comparison with Hook-wire localization, the microcoil localization could reduce the dislocation rate (OR=4.33, 95%CI 2.07 to 9.08, P<0.001), the incidence of pneumothorax (OR=1.62, 95%CI 1.12 to 2.33, P=0.010) and pulmonary hemorrhage (OR=1.64, 95%CI 1.07 to 2.51, P=0.020). ConclusionAlthough Hook-wire localization is slightly better than microcoil localization in the aspect of the success rate of pulmonary nodule localization, microcoil localization has an obvious advantage compared with Hook-wire localization in terms of controlling the incidence of dislocation, pneumothorax and pulmonary hemorrhage. Therefore, from a comprehensive perspective, this study believes that CT-guided microcoil localization is a preoperative localization method worthy of further promotion.

    Release date:2023-06-13 11:24 Export PDF Favorites Scan
  • Application of 3D reconstruction and Hookwire to localize pulmonary nodules in thoracoscopic pulmonary segmentectomy

    ObjectiveTo investigate the clinical value of 3D CT combined with CT-guided Hookwire for localizing small pulmonary nodules in thoracoscopic pulmonary segmentectomy.MethodsFrom December 2017 to February 2019, 39 patients received thoracoscopic pulmonary segmentectomy in our hospital, including 14 males and 25 females with a mean age of 51.33±11.17 years. Before operation, we used Mimics Medical 20.0 to re-establish the anatomy of lung and locate the small pulmonary nodules with Hookwire guided by CT. Based on the position of Hookwire needle, 3D CT images and simulated surgical methods, thoracoscopic pulmonary segmentectomy was performed accurately.ResultsThe surgery was successfully completed in 39 patients without a transfer to open procedure. The mean operation time, mean intraoperative blood loss, mean postoperative hospital stay, mean thoracic tube drainage time were 148.97±28.56 min, 27.95±17.57 mL, 6.95±1.68 d, 4.21±1.95 d, respectively. Postoperative complications occurred in 5 patients (12.82%), including atrial fibrillation in 1, pulmonary infection in 1, chylothorax in 1, intrathoracic hemorrhage in 1 and pneumothorax in 1. All actual surgical margins were larger than 3.0 cm.ConclusionThe application of preoperative 3D CT combined with CT-guided Hookwire to localize small pulmonary nodules is helpful for accurate anatomical segmental resection of the lung, making the operation safe .

    Release date:2020-07-30 02:16 Export PDF Favorites Scan
  • A case report of transcatheter aortic valve replacement with descending aorta severe distortion

    An 89 years old male patient was admitted to the First Medical Center of Chinese PLA General Hospital due to chest tightness and shortness of breath for half a month. Severe aortic valve stenosis was found in post admission assessment. We proposed to perform transcatheter aortic valve replacement surgery. Preoperative evaluation showed severe distortion of the descending aorta. We used the double guide wire technique and a 14F long sheath to assist the stepwise balloon expansion, and successfully completed the valve implantation. For patients with severe tortuous aorta, how to successfully complete transcatheter aortic valve replacement, this case may provide some reference.

    Release date:2020-05-26 02:34 Export PDF Favorites Scan
  • The application of silicon nanowires field-effect transistor biosensor in medicine

    Ultra-sensitive and quantitative analysis of proteins, nucleic acid, virus and other biochemical species are critical technologies for effective dianosis of disease, as well as medical studies. Silicon nanowires field-effect transistor (SiNWs-FET) biosensor is one of the most promising powerful platforms for label-free, real-time, ultra-sensitive detection of analyte. Here, the working principle of SiNWs-FET biosensor and the applications of SiNWs-FET biosensors in medicine were introduced. Moreover, the methods for enhancing the sensitivity of SiNWs-FET biosensor were discussed. Lastly, the prospecting of SiNWs-FET biosensor was presented.

    Release date:2017-10-23 02:15 Export PDF Favorites Scan
  • Effectiveness of Kirschner wire fixation and coracoclavicular ligament reconstruction with suture anchor in treatment of Cho type ⅡC distal clavicle fractures

    Objective To evaluate the effectiveness of Kirschner wire fixation and coracoclavicular ligament reconstruction with suture anchor in the treatment of Cho type ⅡC distal clavicle fractures. Methods The data of 17 patients with Cho type ⅡC distal clavicular fractures, who were treated with Kirschner wire fixation and coracoclavicular ligament reconstruction with suture anchor between June 2019 and June 2021, was retrospectively analyzed. There were 11 males and 6 females with an average age of 38.7 years (range, 19-72 years). The fractures were caused by falling in 12 cases and traffic accident in 5 cases. All patients had fresh closed fractures. The interval from injury to operation was 1-5 days (mean, 2.6 days). The preoperative injury severity score (ISS) was 6-27 (mean, 10.2). The operation time, intraoperative blood loss, hospital stay, fracture healing, and postoperative complications were analyzed. The shoulder joint function was evaluated by disabilities of the arm, shoulder, and hand (DASH) score and Constant score at last follow-up. Results All operations were completed successfully. The operation time was 20-50 minutes (mean, 31.6 minutes). The intraoperative blood loss was 30-100 mL (mean, 50.6 mL). The hospital stay was 4-9 days (mean, 5.3 days). All incisions healed by first intention. All patients were followed up 12-16 months (mean, 13 months). All clavicle fractures healed, and the healing time was 8-15 weeks (mean, 11 weeks). No complications such as fracture displacement or nonunion caused by internal fixation failure occurred. During the follow-up, skin irritation caused by the Kirschner wire withdrawal occurred in 3 cases. The Kirschner wires were removed after fracture healing in 17 patients. At last follow-up, the Constant score of shoulder joint was 90-100 (mean, 98.2). The DASH score was 0-10 (mean, 1.5). ConclusionKirschner wire fixation combined with coracoclavicular ligament reconstruction with suture anchor in the treatment of Cho type ⅡC distal clavicle fractures has less postoperative complications and slight complications. It is convenient to remove the internal fixator. The Kirschner wire does not fix the distal clavicle fracture through the acromion, which has little effect on shoulder joint function and can obtain good effectiveness.

    Release date:2023-12-12 05:05 Export PDF Favorites Scan
  • Effects of low-power wireless power transfer system on memory behavior and part of physiological properties of mice

    Wireless power transfer (WPT) is a new power transmission way, which can be widely used in electric vehicles and other fields. Its electromagnetic environment must be analyzed to ensure safe application. A low-power wireless power transfer system experimental platform was built, with 25 W receiving power and 47 kHz resonant frequency, which was used to carry out animal experiments. Treatment mice were exposed to environment of wireless power transfer system for 5 h a day and 6 days as one cycle. At the end of every cycle, learning memory behavior of mice were detected in T-shaped maze. The exposure experiment lasted for 12 weeks. Finally, immune parameters, sex hormones and part of organ physiological structure were detected. The results are as follows: as exposure time increased, memory behavior of mice did not change obviously with no statistical difference in sex hormone either (P > 0.05), the concentration of immune factors including tumor necrosis factor-α (TNF-α), interleukin 6 (IL-6) and interleukin-1 beta (IL-1β) significantly increased (P < 0.05), and the structure of some organs showed some changes. The experimental results show that the environment of the wireless power transfer system has no effect on the memory behavior of mice, and has some effect on physiological properties of mice.

    Release date:2020-06-28 07:05 Export PDF Favorites Scan
  • Application of thumb blocking technique with ulnar Kirschner wire threading for Gartland type Ⅲ supracondylar humerus fractures in children

    Objective To explore the effectiveness of thumb blocking technique through closed reduction of ulnar Kirschner wire threading in the treatment of Gartland type Ⅲ supracondylar humerus fractures in children. MethodsThe clinical data of 58 children with Gartland type Ⅲ supracondylar humerus fractures treated with closed reduction of ulnar Kirschner wire threading by thumb blocking technique between January 2020 and May 2021 were retrospectively analyzed. There were 31 males and 27 females with an average age of 6.4 years ranging from 2 to 14 years. The causes of injury were falling in 47 cases and sports injury in 11 cases. The time from injury to operation ranged from 24.4 to 70.6 hours, with an average of 49.6 hours. The twitch of ring and little fingers was observed during operation, the injury of ulnar nerve was observed after operation, and the healing time of fracture was recorded. At last follow-up, the effectiveness was evaluated by Flynn elbow score, and the complications were observed. Results There was no twitch of the ring and little fingers when the Kirschner wire was inserted on the ulnar side during operation, and the ulnar nerve was not injured. All children were followed up 6-24 months, with an average of 12.9 months. One child had postoperative infection in the operation area, local skin redness and swelling, and purulent secretion exudation at the eye of the Kirschner wire, which was improved after intravenous infusion and regular dressing change in the outpatient department, and the Kirschner wire was removed after the initial healing of the fracture; 2 children had irritation at the end of the Kirchner wire, and recovered after oral antibiotics and dressing change in the outpatient department. There was no serious complication such as nonunion and malunion, and the fracture healing time ranged from 4 to 6 weeks, with an average of 4.2 weeks. At last follow-up, the effectiveness was evaluated by Flynn elbow score, which was excellent in 52 cases, good in 4 cases, and fair in 2 cases, and the excellent and good rate was 96.6%. ConclusionThe treatment of Gartland type Ⅲ supracondylar humerus fractures in children by closed reduction and ulnar Kirschner wire fixation assisted with thumb blocking technique is safe and stable, and will not cause iatrogenic ulnar nerve injury.

    Release date:2023-02-13 09:57 Export PDF Favorites Scan
  • Effectiveness comparison of suspension fixation plus hinged external fixator and double plate internal fixation in treatment of type C humeral intercondylar fractures

    Objective To compare the effectiveness of suspension fixation plus hinged external fixator with double plate internal fixation in the treatment of type C humeral intercondylar fractures. Methods Between January 2014 and April 2016, 30 patients with type C (Association for the Study of Internal Fixation, AO/ASIF) humeral intercondylar fractures were treated. Kirschner wire suspension fixation plus hinged external fixator was used in 14 cases (group A), and double plate internal fixation in 16 cases (group B). There was no significant difference in gender, age, injury cause, disease duration, injury side, and type of fracture between 2 groups (P>0.05). Results There was no significant difference in operation time and hospitalization stay between 2 groups (P>0.05). But the intraoperative blood loss in group A was significantly less than that in group B (P<0.05); the visual analogue scale (VAS) score at 1 day and 3 days after operation in group A were significantly less than those in group B (P<0.05). Primary healing of incision was obtained in all patients of 2 groups, and no surgery-related complications occurred. The patients were followed up 6-24 months (mean, 12.3 months) in group A and 6-24 months (mean, 12.8 months) in group B. The self-evaluation satisfaction rate was 85.7% (12/14) in group A and was 81.2% (13/16) in group B at 3 months after operation, showing no significant difference (χ2=0.055, P=0.990). Based on the improved Gassebaum elbow performance score at 6 months after operation, excellent and good rate of the elbow function was 78.6% (excellent in 5 cases, good in 6 cases, fair in 2 cases, and poor in 1 case) in group A and was 81.2% (excellent in 6 cases, good in 7 cases, fair in 2 cases, and poor in 1 case) in group B, showing no significant difference between 2 groups (χ2=0.056, P=0.990). Heterotopic ossification occurred at 3 months after operation in 1 case of each group respectively. The X-ray films showed bony union in all cases; no loosening or breakage of screw was observed. The bone union time showed no significant difference between 2 groups (t=–0.028, P=0.978). The time of internal fixation removal, the intraoperative blood loss, and VAS score at 1 day and 3 days after operation in group A were significant better than those in group B (P<0.05). Conclusion The suspension fixation plus hinged external fixator and double plate internal fixation for the treatment of type C humeral intercondylar fractures have ideal outcome in elbow function. But the suspension fixation plus hinged external fixator is better than double plate internal fixation in intraoperative blood loss, postoperative VAS score, and time of internal fixation removal.

    Release date:2017-07-13 11:11 Export PDF Favorites Scan
  • Hookwire术前定位在胸腔镜下肺部孤立性小结节切除术中的应用

    目的总结hookwire术前定位在全胸腔镜下切除肺部直径小于2 cm的孤立性小结节的临床经验。 方法回顾性分析2010年7月至2012年10月中山大学附属中山医院82例肺部孤立性小结节,共88个直径小于2 cm的肺部孤立性病灶,行全胸腔镜下病灶切除术,术前均在数字减影(DSA)Innova CT引导下采用hookwire对病灶穿刺定位的临床资料,其中男47例、女35例,年龄34~78(61.4±10.7)岁。对手指触诊阳性率与病灶临床因素进行相关性分析,比较手指触诊与hookwire定位的成功率,并总结hookwire定位的安全性、有效性及适应证。 结果Hookwire定位常见并发症为无症状气胸13例(14.8%),少量血胸7例(7.9%),严重胸痛3例(3.4%)。9个病灶(10.2%)术中发现穿刺针移位。85个(96.5%)病灶可通过Hookwire准确定位,与触诊(53.4%)准确性差异无统计学意义(P=0.097)。手指触诊的阳性率与病灶的病理类型和病灶的性质有关,对于微浸润性/浸润前病变、肺部单纯性磨玻璃样结节(pure ground-glass opacity,pGGO)的触诊阳性率明显偏低,分别为25.8%和19.2%。 结论对于直径小于2 cm的肺部孤立性结节,胸腔镜手术前hookwire穿刺定位是一项安全的技术。其最佳适应证为直径小于2 cm的pGGO。

    Release date: Export PDF Favorites Scan
6 pages Previous 1 2 3 ... 6 Next

Format

Content