ObjectiveTo investigate the clinical value of 3D CT combined with CT-guided Hookwire for localizing small pulmonary nodules in thoracoscopic pulmonary segmentectomy.MethodsFrom December 2017 to February 2019, 39 patients received thoracoscopic pulmonary segmentectomy in our hospital, including 14 males and 25 females with a mean age of 51.33±11.17 years. Before operation, we used Mimics Medical 20.0 to re-establish the anatomy of lung and locate the small pulmonary nodules with Hookwire guided by CT. Based on the position of Hookwire needle, 3D CT images and simulated surgical methods, thoracoscopic pulmonary segmentectomy was performed accurately.ResultsThe surgery was successfully completed in 39 patients without a transfer to open procedure. The mean operation time, mean intraoperative blood loss, mean postoperative hospital stay, mean thoracic tube drainage time were 148.97±28.56 min, 27.95±17.57 mL, 6.95±1.68 d, 4.21±1.95 d, respectively. Postoperative complications occurred in 5 patients (12.82%), including atrial fibrillation in 1, pulmonary infection in 1, chylothorax in 1, intrathoracic hemorrhage in 1 and pneumothorax in 1. All actual surgical margins were larger than 3.0 cm.ConclusionThe application of preoperative 3D CT combined with CT-guided Hookwire to localize small pulmonary nodules is helpful for accurate anatomical segmental resection of the lung, making the operation safe .
ObjectiveTo systematically evaluate the application effect of CT-guided Hook-wire localization and CT-guided microcoil localization in pulmonary nodules surgery. MethodsThe literatures on the comparison between CT-guided Hook-wire localization and CT-guided microcoil localization for pulmonary nodules were searched in PubMed, EMbase, The Cochrane Library, Web of Science, Wanfang, VIP and CNKI databases from the inception to October 2021. Review Manager (version 5.4) software was used for meta-analysis. The Newcastle-Ottawa Scale (NOS) was used to evaluate the quality of studies.ResultsA total of 10 retrospective cohort studies were included, with 1 117 patients including 473 patients in the CT-guided Hook-wire localization group and 644 patients in the CT-guided microcoil localization group. The quality of the studies was high with NOS scores>6 points. The result of meta-analysis showed that the difference in the localization operation time (MD=0.14, 95%CI −3.43 to 3.71, P=0.940) between the two groups was not statistically significant. However, the localization success rate of the Hook-wire group was superior to the microcoil group (OR=0.35, 95%CI 0.17 to 0.72, P=0.005). In addition, in comparison with Hook-wire localization, the microcoil localization could reduce the dislocation rate (OR=4.33, 95%CI 2.07 to 9.08, P<0.001), the incidence of pneumothorax (OR=1.62, 95%CI 1.12 to 2.33, P=0.010) and pulmonary hemorrhage (OR=1.64, 95%CI 1.07 to 2.51, P=0.020). ConclusionAlthough Hook-wire localization is slightly better than microcoil localization in the aspect of the success rate of pulmonary nodule localization, microcoil localization has an obvious advantage compared with Hook-wire localization in terms of controlling the incidence of dislocation, pneumothorax and pulmonary hemorrhage. Therefore, from a comprehensive perspective, this study believes that CT-guided microcoil localization is a preoperative localization method worthy of further promotion.
ObjectiveTo study the feasibility and safety of CT-guided preoperative Hookwire localization of pulmonary nodules in clinical application.MethodsClinical data of 102 patients who were scheduled to undergo surgical treatment for pulmonary nodules from June 2015 to April 2020 in the North Ward of Thoracic Surgery Department of Ruijin Hospital were retrospectively analyzed. There were 38 males and 64 females, aged 23-82 (53.2±12.8) years.ResultsAll 102 patients with pulmonary nodules underwent CT-guided preoperative Hookwire localization successfully, with a localization success rate of 100.0%. The localization time was 27.0 (11-67) min; the number of times to adjust the angle during the positioning process was 6.9 (3-14); the needle depth of the positioning needle was 41.5 (16.3-69.1) mm. A total of 48 (47.1%) patients had a small amount of bleeding in the lung tissue in the positioning area after positioning; 53 (51.9%) patients had a small amount of pneumothorax after positioning; 16 (15.7%) patients were found that the positioning needle completely shedded from the lung tissue in the subsequent surgery. One patient was transferred to open thoracotomy because of extensive dense adhesion in the thorax, and the remaining 101 patients were operated on under thoracoscopy. Postoperative pathology showed that 5 (4.9%) patients were adenocarcinoma in situ, 28 (27.5%) were microinvasive adenocarcinoma, 36 (35.3%) patients were invasive carcinoma and 32 (31.3%) patients were benign lesions. No patients had complications or adverse events related to preoperative positioning.ConclusionPreoperative CT-guided localization of Hookwire intrapulmonary nodules is safe and effective, and can meet the intraoperative localization needs of thoracic surgeons in most clinical situations, and is not inferior to other preoperative localization methods currently used in clinics.
Objective To compare the results of plate and Kirschner wire fixation in treatment of nonunion of clavicular fracture. Methods From September 1991 to January 2002, 19 patients (9 with plate and 10 with Kirschner wire) were treated. The results were evaluated by reduction, bone union time, recovery of joint function, pain, and correction of deformation. Results The follow-up time was 6-23 months with an average of 11 months. Bone union -occurred after a mean time of 11 weeks. In plate group, 7 patients gained excellent results, 1 good and1 fair. In Kirschner wire group, 3 patients gained excellent results, 3 good, 3 fair and 1 poor. The result of plate is significantly better than that of Kirschner wire fixation(Plt;0.05). Conclusion Plate fixation is a good simple method for treatment of nonunion of clavicular fracture.
ObjectiveTo evaluate the efficacy and safety of a novel wire for echo-guiding percutaneous atrial septal defect (ASD) closure.MethodsTwenty sheep were randomly divided into two groups, an experimental group and a control group (n=10 in each group). In both groups, an animal model of ASD was established by transthoracic balloon dilatation, and percutaneous closure of atrial septal defect was finished only by echography guiding. The total procedure time, passing time (time needed for the guide wire to enter the left atrium), frequency of delivery sheath dropping into right atrium, frequency of arrhythmias and rate of complications were compared between the two groups.ResultsASD model was uneventfully established in all animals. ASD devices were successfully implanted in all sheep. Compared with the control group, the experimental group had significantly less mean procedure time and mean passing time, lower frequency of guide wire dropping into right atrium and frequency of atrial and ventricular premature contractions, respectively (15.36±4.86 min vs. 25.82±7.85 min, 2.69±0.82 min vs. 5.58±3.34 min, 0% vs. 40.0%, 4.41±2.61 vs. 9.60±3.68, 0.75±0.36 vs. 1.34±0.68; all P<0.05) . Two groups did not have serious complications within postoperative one week.ConclusionThe novel wire system is not only safe and effective in the treatment of ASD occlusion, but also easy to operate.
From August 1986 to October 1990, 34 cases of fractures of patella were treated by the self-designed spring Kirschner wire, in which, 25 cases were followed up for an average of 1.5 years. The excellentgood rate reached 88%. In comparing with the traditional method of treatment, it gave more secure fixation for fracture, without the need or only a short time of immobilization needed, short treatment course and satisfactory return of function.
Using electroencephalogram (EEG) signal to control external devices has always been the research focus in the field of brain-computer interface (BCI). This is especially significant for those disabilities who have lost capacity of movements. In this paper, the P300-based BCI and the microcontroller-based wireless radio frequency (RF) technology are utilized to design a smart home control system, which can be used to control household appliances, lighting system, and security devices directly. Experiment results showed that the system was simple, reliable and easy to be populirised.
Objective To compare the effectiveness of open reduction and hook plate fixation versus closed indirect reduction and dorsal extension blocking Kirschner wire fixation for bony mallet fingers. Methods The clinical data of 68 patients with bony mallet finger who admitted between May 2019 and June 2022 were retrospectively analyzed. Among them, 33 cases were in the open group (treated with open reduction and hook plate fixation) and 35 cases were in the closed group (treated with closed indirect reduction and dorsal extension blocking Kirschner wire fixation). There was no significant difference between the two groups in terms of gender, age, the affected side, the affected finger, cause of injury, time from injury to operation, and Wehbé-Schneider classification (P>0.05). The operation time, intraoperative fluoroscopy frequency, fracture healing time, time of returning to work, and postoperative complications were recorded and compared between the two groups. At 12 months after operation, visual analogue scale (VAS) score was used to assess the pain of the injured finger, active flexion range of motion and extension deficit of the distal interphalangeal joint (DIP) were measured by goniometer, and the effectiveness was assessed by Crawford criteria. Results All patients in the two groups were followed up 12-26 months, with an average of 15 months. There was no significant difference in the follow-up time between the closed group and the open group (P>0.05). The operation time in the closed group was shorter than that in the open group, and the intraoperative fluoroscopy times, the fracture healing time, and the time of returning to work in the closed group were more than those in the open group, and the differences were significant (P<0.05). In the closed group, there were 5 cases of pinning tract infection and 3 cases of small area pressure ulcer skin necrosis on the dorsal side of the finger, which were cured after intensive nursing and dressing change. Local nail depression deformity occurred in 7 cases in the open group, and the deformity disappeared after removal of plate. The incisions of the other patients healed uneventfully without complications such as infection, skin necrosis, exposure of the internal fixation, or nail deformity. There was no significant difference in the incidence of skin necrosis between the two groups (P>0.05), but the differences in the incidence of infection and nail deformity between the two groups were significant (P<0.05). There was no significant difference in VAS score, DIP active flexion range of motion, DIP extension deficiency, or Crawford criteria evaluation between the two groups at 12 months after operation (P>0.05). At last follow-up, there was no DIP osteoarthritis and joint degeneration in both groups. Conclusion Open reduction and hook plate fixation versus closed indirect reduction and dorsal extension blocking Kirschner wire fixation have their own advantages and disadvantages, but both of them have good results in the treatment of bony mallet fingers. Open reduction and hook plate fixation is recommended for young patients with bony mallet fingers who are eager to return to work.
ObjectiveTo investigate the effectiveness of Kirschner wire fixation in scapholunate joint, capitolunate joint, and lunotriquetral joint combined with bone anchor repair for the treatment of acute perilunate injury. MethodsBetween January 2007 and January 2012, 35 cases of acute perilunate injury were treated. There were 30 males and 5 females with an average age of 45.5 years (range, 32-56 years). Fractures were caused by falling from height in 18 cases, by traffic accident in 11 cases, and by fall injury in 4 cases. The time from injury to operation was 2-6 days (mean, 3.4 days). There were 23 cases of trans-scaphoid perilunate dislocation, 10 cases of perilunate dislocation, and 2 cases of trans-triangular perilunate dislocation. Associated injuries included median nerve injury in 6 cases, radius styloid fracture in 8 cases, ulnar styloid fracture in 2 cases, and distal tibial fracture in 1 case. All the patients were treated by open reduction, Herbert screw fixation of scaphoid fractures, and Kirschner wire fixation in scapholunate joint, capitolunate joint, and lunotriquetral joint, and the intercarpal ligaments were repaired by Mitek bone anchor. ResultsSuperficial wound infection occurred in 2 cases, and primary healing of incision obtained in others. Thirty-five patients were followed up 12-35 months (mean, 18 months). X-ray films showed fracture union in 21 cases of scaphoid fractures, and bone nonunion in 2 cases of scaphoid fractures. During the follow-up period, there was no avascular necrosis of scaphoid or lunate. At last follow-up, the scapholunate angle, radiolunate angle, and wrist range of motion (ROM) in extension had no significant difference between affected and unaffected sides (P > 0.05). The wrist ROM in flexion and grip strength of affected side were not up to the levels of unaffected side (P < 0.05). According to the modified Mayo wrist scoring system, the score was 79.9±10.7, which were excellent in 8 cases, good in 17 cases, fair in 7 cases, and poor in 3 cases, and the excellent and good rate was 71.4%. The disability of arm-shoulder-hand (DASH) questionnaires score was 21±10. Traumatic osteoarthritis was observed in 2 cases. ConclusionKirschner wire fixation in scapholunate joint, capitolunate joint, and lunotriquetral joint combined with bone anchor repair for the treatment of acute perilunate injury can get early stability of the carpal joint, favorable intercarpal ligament repair, and good recovery of wrist joint function.
ObjectiveTo explore the effectiveness of arthroscopic treatment of scaphoid fracture nonunion with bone graft and Kirschner wire combined with screw fixation. MethodsThe clinical data of 14 patients with scaphoid fracture nonunion who met the selection criteria between February 2021 and September 2022 were retrospectively analyzed. There were 13 males and 1 female with an average age of 32 years ranging from 17 to 54 years. The time from injury to operation ranged from 6 to 15 months, with an average of 9.6 months. According to the Slade-Geissler classification of scaphoid fracture nonunion, there were 3 cases of grade Ⅲ, 8 cases of grade Ⅳ, and 3 cases of grade Ⅴ. The preoperative visual analogue scale (VAS) score was 5.9±1.0, and the modified Mayo wrist score was 53.2±9.1. There were 2 cases of scaphoid nonunion advanced collapse, both of which were stage Ⅰ. All patients were treated with arthroscopic bone graft and Kirschner wire combined with screw fixation, and the fracture healing was observed by X-ray film monthly after operation, and the effectiveness was evaluated by VAS score and modified Mayo wrist score before and after operation. ResultsAll patients were followed up 6-14 months, with an average of 8.4 months. All fractures healed in 4-8 months, with an average of 6.3 months. The postoperative pain symptoms and wrist function of the patients significantly improved when compared with those before operation, and the VAS score at last follow-up was 2.4±1.3, and the modified Mayo wrist score was 87.1±6.7, which were significantly different from those before operation (t=12.851, P<0.001; t=−14.410, P<0.001). According to the modified Mayo wrist evaluation, 9 cases were excellent, 3 cases were good, and 2 cases were fair. Conclusion Arthroscopic bone graft and Kirschner wire combined with screw fixation is an effective surgical method for the treatment of scaphoid fracture nonunion.