west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "internal fixation" 282 results
  • Influence of isobar ttl dynamic internal fixation system on adjacent segment degeneration by mri measurement of lumbar nucleus pulposus volume

    ObjectiveTo investigate the influence of ISOBAR TTL dynamic internal fixation system on degeneration of adjacent intervertebral disc by MRI measurement of lumbar nucleus pulposus volume in treating lumbar degenerative disease after operation. MethodsBetween March 2010 and October 2011, 34 patients with lumbar intervertebral disc herniation (23 cases of paracentral type and 11 cases of lateral type) underwent operation with ISOBAR TTL dynamic internal fixation system for fixation of single segment, and the clinical data were analyzed retrospectively. There were 20 males and 14 females, aged 39-62 years (mean, 47.5 years). The disease duration was 6-18 months (mean, 14 months). Involved segments included L4, 5 in 21 cases and L5, S1 in 13 cases. The X-ray films and MRI images were taken at 6, 12, 18, 24, 36, and 48 months after surgery. Based on X-ray films, the height of intervertebral space was measured using angle bisectrix method. The nucleus pulposus volume was measured based on the MRI scan. The postoperative change of nucleus pulposus volume and intervertebral disc height were used to evaluate the influence of ISOBAR TTL system on degeneration of adjacent intervertebral disc nucleus pulposus. ResultsThirty patients were followed up 48 months. The height of intervertebral space showed no significant difference between at pre-and post-operation (P>0.05). The nucleus pulposus volume increased after operation, showing no significant difference at 6, 12, and 18 months when compared with preoperative value (P>0.05), but significant difference was found at 24, 36, and 48 months when compared with preoperative value (P < 0.05). The height of nucleus pulposus increased after operation but the width was decreased; the values showed no significant difference at 6, 12, and 18 months when compared with preoperative ones, but showed significant difference at 24, 36, and 48 months when compared with preoperative ones (P < 0.05). The diameter of nucleus pulposus at 18, 24, 36, and 48 months after operation was significantly langer than that at preoperation (P < 0.05). ConclusionISOBAR TTL dynamic internal fixation system can prevent or delay the degeneration of intervertebral discs.

    Release date: Export PDF Favorites Scan
  • The effect of the sequence of intermediate instrumentation and distraction-reduction of the fractured vertebrae on the surgical treatment of mild to moderate thoracolumbar burst fractures

    Objective To investigate the effect of the sequence of intermediate instrumentation with long screws and distraction-reduction on mild to moderate thoracolumbar fractures treated by posterior open and short-segmental fixation. MethodsThe clinical data of 68 patients with mild to moderate thoracolumbar burst fractures who met the selection criteria between January 2016 and June 2019 were retrospectively analyzed. The patients were divided into group ISDRF (intermediate screws then distraction-reduction fixation, 32 cases) and group DRISF (distraction-reduction then intermediate screws fixation, 36 cases) according to the different operation methods. There was no significant difference between the two groups in age, gender, body mass index, fracture segment, cause of injury, and preoperative load-sharing classification score, thoracolumbar injury classification and severity score, vertebral canal occupational rate, back pain visual analogue scale (VAS) score, anterior height of fractured vertebra, and Cobb angle (P>0.05). The operation time, intraoperative blood loss, complications, and fracture healing time were recorded and compared between the two groups. The vertebral canal occupational rate, anterior height of fractured vertebra, kyphosis Cobb angle, and back pain VAS score before and after operation were used to evaluate the effectiveness. Results There was no significant difference in intraoperative blood loss and operation time between the two groups (P>0.05). No vascular or spinal nerve injury and deep infections or skin infections occurred in both groups. At 1 week after operation, the vertebral canal occupational rate in the two groups was significantly improved when compared with that before operation (P<0.05), no significant difference was found in the difference of vertebral canal occupational rate before and after operation and improvement between the two groups (P>0.05). The patients in both groups were followed up 18-24 months, with an average of 22.3 months. All vertebral fractures reached bone union at 6 months postoperatively. At last follow-up, there was no internal fixation failures such as broken screws, broken rods or loose screws, but there were 2 cases of mild back pain in the ISDRF group. The intra-group comparison showed that the back pain VAS score, the anterior height of fractured vertebra, and the Cobb angle of the two groups were significantly improved at each time point postoperatively (P<0.05); the VAS scores at 12 months postoperatively and last follow-up were also improved when compared with that at 1 week postoperatively (P<0.05). At last follow-up, the anterior height of fractured vertebra in the ISDRF group was significantly lost when compared with that at 1 week and 12 months postoperatively (P<0.05), the Cobb angle had a significant loss when compared with that at 1 week postoperatively (P<0.05); the anterior height of fractured vertebra and Cobb angle in DRISF group were not significantly lost when compared with that at 1 week and 12 months postoperatively (P>0.05). The comparison between groups showed that there was no significant difference in the remission rate of VAS score between the two groups at 1 week postoperatively (P>0.05), the recovery value of the anterior height of fractured vertebra in ISDRF group was significantly higher than that in DRISF group (P<0.05), the loss rate at last follow-up was also significantly higher (P<0.05); the correction rate of Cobb angle in ISDRF group was significantly higher than that in DRISF group at 1 week postoperatively (P<0.05), but there was no significant difference in the loss rate of Cobb angle between the two groups at last follow-up (P>0.05). ConclusionIn the treatment of mild to moderate thoracolumbar burst fractures with posterior short-segment fixation, the instrumentation of long screws in the injured vertebrae does not affect the reduction of the fracture fragments in the spinal canal. DRISF can better maintain the restored anterior height of the fractured vertebra and reduce the loss of kyphosis Cobb angle during the follow-up, indicating a better long-term effectiveness.

    Release date:2022-06-08 10:32 Export PDF Favorites Scan
  • Clinical study on the subchondral screw compression technique assisted reduction of residual or secondary collapse of lateral tibial plateau

    Objective To explore the reduction and support effect of the subchondral screw compression technique for residual or secondary collapse of the lateral tibial plateau during operation. Methods Between January 2020 and June 2021, 11 patients with residual or secondary collapse of the lateral tibial plateau during operation were treated with the subchondral screw compression technique. There were 6 males and 5 females, aged 52.3 years old (range, 27-64 years). The fractures were caused by traffic accident in 10 cases and falling from height in 1 case and located at the left knee in 6 cases and the right knee in 5 cases. According to Schatzker classification, there were 5 cases of type Ⅱ fractures, 4 cases of type Ⅲ fractures, and 2 cases of type Ⅴfractures. According to the three columns classification, there were 5 cases of lateral column, 4 cases of lateral column and posterior column, and 2 cases of three columns. The time from injury to operation was 4.5 days (range, 3-7 days). During the follow-up, X-ray films were obtained and the Rasmussen standard was used to evaluate the quality of fracture reduction, meanwhile fracture healing was observed. The medial proximal tibial angle (mPTA), posterior tibial slope angle (pTSA), and articular surface collapse were measured at immediate and 12 months after operation. The knee joint range of motion was evaluated at last follow-up, and the knee joint function was evaluated using the Hospital for Special Surgery (HSS) score. Results All operations were successfully completed, with a mean operation time of 71.4 minutes (range, 55-120 minutes), and a mean hospital stay of 8.0 days (range, 5-13 days). The incisions all healed by first intention, without complications such as infection, flap necrosis, or vascular and nerve injury. All patients were followed up 16.5 months on average (range, 12-24 months). X-ray films showed that the fracture reduction score was 14-18 (mean, 16.7) according to Rasmussen score criteria; and 5 cases were rated as excellent and 6 as good. All fractures healed clinically with a mean clinical healing time of 14.9 weeks (range, 12-16 weeks), and there was no complications such as plate or screw loosening. At 12 months after operation, the mPTA and pTSA were (87.5±1.7)° and (6.2±3.1)°, respectively; there was no significant difference when compared to the values at immediate after operation [(87.6±1.8)° and (6.5±3.1)°] (P>0.05). The articular surface of the tibial plateaus was effectively supported, and it collapsed again by 0-1.0 mm at 12 months, with an average of 0.4 mm. At last follow-up, the knee joint range of motion was 115°-135° (mean, 126.8°) and the HSS score for knee joint function was 87-98 (mean, 93.9). Five patients underwent secondary operation to remove the internal fixator at 12-18 months after operation.ConclusionThe subchondral screw compression technique is helpful for the reduction of residual or secondary collapse of the lateral tibial plateau during operation, and can provide good support for osteochondral blocks.

    Release date:2023-12-12 05:09 Export PDF Favorites Scan
  • Effectiveness of proximal femoral nail anti-rotation and cerclage fixation for complicated femoral subtrochanteric fractures

    ObjectiveTo investigate the effectiveness of proximal femoral nail anti-rotation (PFNA) and cerclage fixation for complicated femoral subtrochanteric fractures.MethodsA clinical data of 74 patients with complicated femoral subtrochanteric fractures, who were admitted between March 2016 and March 2019 and met the criteria, was retrospectively analyzed. Among them, 39 patients were treated with limited open reduction and PFNA combined with cerclage fixation (observation group) and 35 patients were treated with closed reduction and PFNA fixation (control group). There was no significant difference in gender, age, cause of injury, side and type of fracture, and the time from injury to operation (P>0.05). The ratio of postoperative hemoglobin (1, 3, and 5 days) to the preoperative hemoglobin, the operation time, the first weight-bearing time after operation, and the hospital stay were recorded. X-ray films were taken to observe fracture healing in the two groups and bone resorption around the cerclage in the observation group, and the fracture healing time was recorded. Hip function was evaluated by Harris scoring. ResultsThe operation time of the observation group was significantly longer than that of the control group (P<0.05), but the first weight-bearing time and hospital stay were significantly shorter (P<0.05). All patients were followed up 12 months. There was no significant difference in the ratios of post- to pre-operative hemoglobin (1, 3, and 5 days) between the two groups (P>0.05). X-ray film reexamination showed that the fractures of the two groups healed smoothly, and the fracture healing time of the observation group was significantly shorter than that of the control group (t=−12.989, P=0.000). No bone resorption around the cerclage occurred in the observation group. The Harris scores of the observation group were better than those of the control group at 7 days and 1, 2, and 3 months after operation (P<0.05), and there was no significant difference between the two groups at 6 months after operation (t=1.329, P=0.180).ConclusionCompared with PFNA fixation, PFNA combined with cerclage fixation for the complicated femoral subtrochanteric fractures has a shorter operation time, and can obtain immediate stability after fixation, which can meet the needs of patients for early functional exercise.

    Release date:2021-08-30 02:26 Export PDF Favorites Scan
  • Open reduction and internal fixation for multiple injuries of superior shoulder suspensory complex with coracoid process fracture

    ObjectiveTo investigate the effectiveness of open reduction and internal fixation for multiple injuries of superior shoulder suspensory complex (SSSC) with coracoid process fracture.MethodsBetween January 2014 and October 2018, 22 patients with multiple injuries of SSSC with coracoid process fracture were treated by open reduction and internal fixation. There were 16 males and 6 females, aged from 24 to 72 years with an average age of 36.6 years. There were 10 cases of falling injury, 5 cases of traffic accident injury, and 7 cases of falling from height injury. All of them were fresh closed injuries. The time from injury to operation ranged from 2 to 17 days with an average of 6.9 days. Both X-ray film and CT showed the coracoid process fracture complicated with clavicular fracture in 14 cases, acromioclavicular joint dislocation in 12 cases, and acromioclavicular fracture in 5 cases. There were 14 cases of two places of SSSC, 7 cases of three places of SSSC, and 1 case of four places of SSSC.ResultsAll incisions healed in primary stage after operation. All patients were followed up 10-24 months with an average of 14.1 months. X-ray films showed that all fractures healed and the acromioclavicular joint was normal. The healing time ranged from 6 to 12 months, with an average of 6.2 months. No complications such as internal fixation failure and nonunion occurred. According to University of California Los Angeles (UCLA) shoulder scoring system, the shoulder joint function was rated as excellent in 15 cases, good in 5 cases, and poor in 2 cases at last follow-up. The excellent and good rate was 90.9%.ConclusionOpen reduction and internal fixation for treatment of multiple injuries of SSSC with coracoid process fracture is firm and reliable. Combined with active postoperative rehabilitation program intervention, it can accelerate the recovery of shoulder joint function and achieve satisfactory effectiveness.

    Release date:2020-04-15 09:18 Export PDF Favorites Scan
  • CURATIVE EFFECT OF MINIMALLY INVASIVE PERCUTANEOUS PLATE OSTEOSYNTHESIS ASSISTED BY ARTHROSCOPY ON 29 CASES OF TIBIAL PLATEAU FRACTURES

    Objective To investigate the cl inical effect of minimally invasive internal fixation percutaneous plate osteosynthesis (MIPPO) assisted by arthroscopy on tibial plateau fractures. Methods From September 2005 to December 2007, 29 patients with tibial plateau fracture underwent arthroscopy-assisted MIPPO, including 18 males and 11 females aged18-59 years old (average 34.7 years old). There were 8 cases of type II, 10 of type III, 5 of type IV, 3 of type V, and 3 of type VI according to Schatzker classification system. The fracture was combined with meniscus injury in 13 cases, anterior cruciate l igament injury in 4 cases, and medial collateral l igament injury in 3 cases. The time from injury to operation was 2-10 days. Firstly, the combined injury was treated under arthroscopy. Then, reduction of tibial plateau fractures was performed, bone grafting was conducted in the area of bone defect, and internal fixation using strut plates was performed after establ ishing subcutaneous tunnel via minimally invasion. Early rehabil itation activities were carried out for each patient 1 day after operation. Results No early compl ications such as poor heal ing of incisions, infections, and osteofascial compartment syndrome occurred. Over the follow-up period of 12-39 months (average 24 months), there was no failure of internal fixation, traumatic knee osteoarthritis, and inversion and eversion of the knee. The fractures healed within 3-4.5 months (average 3.5 months). The cl inical effect was excellent in 23 cases, good in 4 cases, and fair in 2 cases according to Lysholm knee rating system, and the excellent and good rate was 93.1%. Conclusion Arthroscopy-assisted MIPPO is a safe and effective way of managing tibial plateau fractures due to its features of minimal invasion, earl ier recovery, fewer compl ications, and simultaneous treatment of associated intra-articular injuries.

    Release date:2016-09-01 09:07 Export PDF Favorites Scan
  • Progress in surgical treatment of inferior patellar pole fractures

    Objective To summarize the surgical treatment methods and progress of inferior patellar pole fractures and provide reference for clinical application. Methods The literature on surgical treatment of inferior patellar pole fractures was extensively reviewed, and the relevant research progress, advantages, and limitations were summarized. Results The inferior pole of the patella is an important part of the knee extension device, which can strengthen the force arm of the quadriceps. Inferior patellar pole fractures are relatively rare and often comminuted, usually requiring surgical treatment. At present, there are various methods to treat inferior patellar pole fractures, including patellectomy of inferior pole, tension-band wiring technique, plate internal fixation, suture anchor fixation, claw-like shape memory alloy, separate vertical wiring technique. Different methods have their own characteristics, advantages, and disadvantages. The single internal fixation method has more complications and is easy to cause fixation failure. Therefore, the trend of combining various internal fixation methods is developing at present. Conclusion When the main fragment of the inferior patellar pole fracture is large and mainly distributed transversely, the combination protocol based on tension-band wiring technique can be regarded as an ideal choice. When the fragments are severely damaged and small, the comprehensive protocol based on suture fixation can result in a better postoperative functional recovery.

    Release date:2023-02-13 09:57 Export PDF Favorites Scan
  • Effectiveness comparison of suspension fixation plus hinged external fixator and double plate internal fixation in treatment of type C humeral intercondylar fractures

    Objective To compare the effectiveness of suspension fixation plus hinged external fixator with double plate internal fixation in the treatment of type C humeral intercondylar fractures. Methods Between January 2014 and April 2016, 30 patients with type C (Association for the Study of Internal Fixation, AO/ASIF) humeral intercondylar fractures were treated. Kirschner wire suspension fixation plus hinged external fixator was used in 14 cases (group A), and double plate internal fixation in 16 cases (group B). There was no significant difference in gender, age, injury cause, disease duration, injury side, and type of fracture between 2 groups (P>0.05). Results There was no significant difference in operation time and hospitalization stay between 2 groups (P>0.05). But the intraoperative blood loss in group A was significantly less than that in group B (P<0.05); the visual analogue scale (VAS) score at 1 day and 3 days after operation in group A were significantly less than those in group B (P<0.05). Primary healing of incision was obtained in all patients of 2 groups, and no surgery-related complications occurred. The patients were followed up 6-24 months (mean, 12.3 months) in group A and 6-24 months (mean, 12.8 months) in group B. The self-evaluation satisfaction rate was 85.7% (12/14) in group A and was 81.2% (13/16) in group B at 3 months after operation, showing no significant difference (χ2=0.055, P=0.990). Based on the improved Gassebaum elbow performance score at 6 months after operation, excellent and good rate of the elbow function was 78.6% (excellent in 5 cases, good in 6 cases, fair in 2 cases, and poor in 1 case) in group A and was 81.2% (excellent in 6 cases, good in 7 cases, fair in 2 cases, and poor in 1 case) in group B, showing no significant difference between 2 groups (χ2=0.056, P=0.990). Heterotopic ossification occurred at 3 months after operation in 1 case of each group respectively. The X-ray films showed bony union in all cases; no loosening or breakage of screw was observed. The bone union time showed no significant difference between 2 groups (t=–0.028, P=0.978). The time of internal fixation removal, the intraoperative blood loss, and VAS score at 1 day and 3 days after operation in group A were significant better than those in group B (P<0.05). Conclusion The suspension fixation plus hinged external fixator and double plate internal fixation for the treatment of type C humeral intercondylar fractures have ideal outcome in elbow function. But the suspension fixation plus hinged external fixator is better than double plate internal fixation in intraoperative blood loss, postoperative VAS score, and time of internal fixation removal.

    Release date:2017-07-13 11:11 Export PDF Favorites Scan
  • Effectiveness of vertical compression of locking plate combined with hollow screws in treatment of Sanders type Ⅱ and Ⅲ calcaneal fractures

    Objective To probe into the effectiveness of vertical compression of locking plate combined with hollow screws in the treatment of Sanders type Ⅱ and Ⅲ calcaneal fractures. MethodsThe clinical data of 128 patients with Sanders type Ⅱ and Ⅲ calcaneal fractures who were admitted between March 2019 and April 2022 and met the selection criteria were retrospectively analyzed. Among them, 65 patients were treated with locking plate combined with hollow screw vertical compression (study group), and 63 patients were treated with simple locking plate (control group). There was no significant difference in baseline data between the two groups (P>0.05), such as gender, age, fracture side and Sanders classification, cause of injury, time from injury to operation. The operation time, intraoperative blood loss, hospital stay, and fracture healing time were recorded and compared between the two groups. Before operation and at 12 months after operation, the American Orthopaedic Foot and Ankle Association (AOFAS) score (including total score, pain score, functional score, and alignment score) was used to evaluate the recovery of foot function, and imaging indicators such as calcaneal width, calcaneal height, calcaneal length, Böhler angle, and Gissane angle were measured on X-ray films. ResultsAll patients were followed up 12 months after operation. There was no significant difference in operation time, intraoperative blood loss, hospital stay, and fracture healing time between the two groups (P>0.05). Poor wound healing occurred in 1 case in the study group and 2 cases in the control group. At 12 months after operation, there was no significant difference between the two groups in the pre- and post-operative difference of calcaneal length, calcaneal height, Gissane angle, and Böhler angle (P>0.05). However, the pre- and post-operative difference in calcaneal width in the study group was significantly higher than that in the control group (P<0.05). The pre- and post-operative difference of AOFAS total score in the study group was significantly higher than that in the control group (P<0.05), and further analysis showed that the pre- and post-operative difference of pain and function scores in the study group were significantly higher than those in the control group (P<0.05), while there was no significant difference in the pre- and post-operative difference of force score between the two groups (P>0.05). ConclusionCompared with simple locking plate treatment, the treatment of Sanders type Ⅱ and Ⅲ calcaneal fractures with vertical compression of locking plate combined with hollow screws can more effectively improve the width of the subtalar calcaneal articular surface, avoid peroneal longus and brevis impingement, reduce pain, and increase the range of motion of the subtalar joint, and the effectiveness is better.

    Release date:2024-05-13 02:25 Export PDF Favorites Scan
  • Treatment of Gartland type Ⅱ and Ⅲ supracondylar fracture of humerus in children

    ObjectiveTo analyze the treatment of Gartland type Ⅱ and Ⅲ supracondylar fracture of the humerus in children.MethodsBetween January 2015 and January 2017, 45 cases of Gartland type Ⅱ and Ⅲ supracondylar fracture of the humerus were treated. There were 28 boys and 17 girls with an age of 1-13 years (mean, 5.7 years). The causes of injury included sports injury in 43 cases and falling from height in 2 cases. Fractures were classified as type Ⅱ in 12 cases and type Ⅲ in 33 cases according to Gartland classification. The time from injury to operation was 2-12 hours (mean, 4.6 hours). All fractures were treated with closed reduction first, and 12 cases of Gartland type Ⅱ fracture were successful in closed reduction; 20 cases of Gartland type Ⅲ fracture were successful in closed reduction, 11 cases with reduction failure and 2 cases with radial nerve injury underwent assisted anterior transverse approach reduction. Then percutaneous crossed Kirschner wires fixation was performed.ResultsThe operation time was 16-52 minutes (mean, 32 minutes). The perspective frequency was 4-17 times (mean, 6.7 times). The hospitalization time was 3-7 days (mean, 4 days). All the 45 cases were followed up 8-20 months (mean, 12 months). The ulnar nerve paralysis occurred in 3 cases of Gartland type Ⅲ fracture that were treated with closed reduction, and recovered after 1-3 months. All fractures healed after operation, and the healing time was 2-3 months. No incision infection, Volkmann muscle contracture, and other complications occurred. The elbow joint function score at 6 months after operation showed that the results of closed reduction was excellent in 16 cases, good in 12 cases, and fair in 4 cases, with the excellent and good rate of 87.5%; in which Gartland type Ⅱ fracture was excellent in 9 cases and good in 3 cases, with an excellent and good rate of 100%, and Gartland Ⅲ was excellent in 7 cases, good in 9 cases, and fair in 4 cases with an excellent and good rate of 80%. The results of assisted anterior transverse approach reduction was excellent in 7 cases, good in 5 cases, and fair in 1 case, and the excellent and good rate was 92.3%.ConclusionGartland type Ⅱ and Ⅲ supracondylar fractures of the humerus can be treated with closed reduction or combined with the assisted anterior transverse approach reduction, then fixed by percutaneous crossed Kirschner wire, which is operational, smaller invasive, and less radiation exposure during operation, while postoperative function is good.

    Release date:2018-05-30 04:28 Export PDF Favorites Scan
29 pages Previous 1 2 3 ... 29 Next

Format

Content