west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "呼出气一氧化氮" 14 results
  • The Diagnostic Value of the Fractional Exhaled Nitric Oxide for Asthma

    Objective To determine the diagnostic value of fractional exhaled nitric ( FeNO)measurement in diagnosis of bronchial asthma. Methods The patients with unkown-cause respiratory symptoms including wheezing, cough, and breathlessness were enrolled from August to September in 2008.FeNO was measured by nitric oxide analyzer ( NIOX; Aerocrine AB; Solna, Sweden) . Bronchial challenge test ( BCT) or bronchodilator test was defined as golden standard for asthma diagnosis. The value of FeNO was assessed and the optimal operating point of FeNO testing was determined by the means of the receiver operating characteristic ( ROC) curves. Results A total of 101 patients were enrolled, in which 48 cases were diagnosed as asthma by positive yield in BCT ( in 38 cases) or bronchodilator test ( in 10 cases) . The severity of airway hyperresponsiveness ( AHR) judged by BCT was mild in 15 cases, moderate in 15 cases and severe in 8 cases. The levels of FeNO of asthma group were higher than those of non-asthma group [ ( 68. 19 ±43. 00) ppb vs ( 19. 52 ±10. 60) ppb, P lt; 0. 05] . A linear correlation of FeNO with lnPD20 FEV1 was revealed in the cases with AHR. Area under ROC curve was 0. 9. The optimal diagnostic cutoff point was 36. 5 ppb which was capable of differentiating asthma and non-asthma with sensitivity of 92. 7% ,specificity of 83. 3% , positive predictive value of 79. 17% , negative predictive value of 94. 34% and accuracy of 87. 13% . Conclusion FeNO test may be helpful in the diagnosis of asthma with high sensitivity and specificity.

    Release date:2016-09-14 11:23 Export PDF Favorites Scan
  • Atypical Asthma with Chief Complaint of Palpitations: Twelve Cases Analysis

    ObjectiveTo explore the clinical features of atypical bronchial asthma with chief complaint of palpitations. MethodsTwelve cases with unexplained palpitations diagnosed by asthma were analyzed retrospectively. ResultsThe patients were diagnosed with asthma through bronchodilation test,skin prick tests,fractional exhaled nitric oxide (FeNO) and diagnostic treatment.The ratio of male to female cases was 1:5. The ventilation lung function of all patients was in normal range. The median time of misdiagnosis was 13.5(3-120) months. 41.6% of cases had dust mite positive skin prick test. The median value of FeNO was 32.75(18-54) ppb. The symptoms of all patients were relieved completely after standard treatment. ConclusionPalpatation may be a specific presentation of asthma characterized with eosinophilic airway inflammation which may be misdiagnosed as other diseases for a long time,especially in elder women. To improve the knowledge of this kind of atypical asthma,detailed medical history, experimental examinations and diagnostic treatment response are important to confirm the diagnosis in time.

    Release date:2016-08-30 11:31 Export PDF Favorites Scan
  • Diagnosis of Asthma with the Measurement of Exhaled Nitric Oxide: A Systematic Review

    Objective To review literatures regarding the diagnosis of asthma with the measurement of exhaled nitric oxide( eNO) and assess the effectiveness and accuracy of eNO in the diagnosis of asthma.Methods MEDLINE, OVID, CBMdisc, CNKI( 1991 to 2008) for studies involving the diagnostic value of eNO were searched, and references of included studies were also hand searched. QUADAS ( Quality Assessment of Diagnostic Accuracy Studies) items were used for quality assessment in the systematic review. Meta-disc software was used to analyze heterogeneity. Sensitivity, specificity and summary diagnostic odds ratio( SDOR) were used for the pooled analysis. The summary receiver operating characteristic ( SROC)curves were drew and the summary areas under the SROC ( SAUC) were calculated. Finally, sensitivity analysis was performed. Results Eleven literatures with15 studies were included. These 15 studies had well controlled the bias of partial verification, differential verification, incorporation and withdrawals. The possibility of the disease progression bias was less and the reference standard review could have a greater bias. The spectrumcomposition of a study, the inclusion and exclusion criteria and the reporting quality were poorly reported. In statistical analysis, the totally pooled sensitivity, pooled specificity, SDOR, SAUC of the measurement of eNO in the diagnosis of asthma was 0. 68, 0. 79, 12. 73, 0. 8446, respectively. Sensitivity analysis demonstrated no disproportionate influences of individual study. Conclusions eNO has a certain value in the diagnosis of asthma. To make further analysis, more studies with high quality are needed.

    Release date:2016-09-14 11:23 Export PDF Favorites Scan
  • The Predictive Value of Fractional Exhaled Nitric Oxide in the Treatment Response of Adult Asthmatic Patients

    ObjectiveTo explore the predictive value of fractional exhaled nitric oxide (FeNO) in the treatment response of adult asthmatic patients. Methods64 adult outpatients with asthma from Peking Union Hospital between March and September 2013 were recruited in the study. All patients completed asthma control test (ACT) together with exhaled nitric oxide (FeNO) and pulmonary function test. Then the patients were classified into a higher FeNO group (n=33) and a normal FeNO group (n=31) according to FeNO level. All patients accepted regular inhaled ICS/LABA treatment (salmeterol and fluticasone 50/250). Three months later all patients reaccepted ACT,FeNO and pulmonary function test. ResultsThe ACT score increased in all patients,and was significantly higher in the higher FeNO group than that in the normal FeNO group[22.07±5.49 vs. 19.23±5.48,t=2.893,P<0.05]. The complete control rate of the higher FeNO group was higher than that in the normal FeNO group (42.42% vs. 19.35%,χ2=3.960,P<0.05). The FEV1 and FEV1%pred of two groups both increased significantly (P<0.05),but there was no significant difference between two groups (P>0.05). Correlation analysis showed that FeNO and the declined rate of FeNO was negatively correlated with the ACT score(r=-0.302,P<0.05;r=0.674,P<0.01) and positively correlated with the improvement of ACT score (r=0.514,P<0.01;r=0.674,P<0.01). No significant correlation was found between FeNO and FEV1 or FEV1%pred. ConclusionThe effect of ICS/LABA therapy is better for asthma patients with higher FeNO. FeNO can be used for predicting the response to ICS/LABA therapy in patients with asthma and guiding the treatment.

    Release date:2016-08-30 11:31 Export PDF Favorites Scan
  • The predictive effect of fractional exhaled nitric oxide measurement on treatment in COPD patients with different phenotype of acute exacerbation frequency

    ObjectiveThrough measuring fractional exhaled nitric oxide (FeNO) and eosinophil levels of peripheral blood in chronic obstructive pulmonary disease (COPD) patients with different phenotype of acute exacerbation frequency, to predict the therapeutic effect of glucocorticoid therapy and guide the clinical treatment of different subtypes patients with acute exacerbations of COPD.MethodsA total of 127 patients with acute exacerbation of COPD in Suining Central Hospital from February 2017 to October 2019 were recruited. They were divided four groups according to the number of acute exacerbations in the past one year and the treatment scheme, ie. a frequent acute exacerbation with glucocorticoid treatment group (34 cases), a frequent acute exacerbation with non-glucocorticoid treatment group (31 cases), a non-frequent acute exacerbation with glucocorticoid treatment group (30 cases), and a non-frequent acute exacerbation with non-glucocorticoid treatment group (32 cases). FeNO value, eosinophil ratio in peripheral blood, COPD assessment test (CAT) score, and interleukin-8 (IL-8) concentration were measured before and on the 10th day of treatment, and the differences within group and between groups before and after treatment were compared.ResultsCAT score, FeNO, eosinophil ratio and IL-8 level in the four groups were significantly improved on the 10th day after treatment (all P<0.05). The declines of FeNO value, eosinophil ratio, and IL-8 level on the 10th day of treatment compared with those before treatment in the frequent acute exacerbation with glucocorticoid treatment group and the frequent acute exacerbations with non-glucocorticoid treatment group were larger than those in the non-frequent acute exacerbation with glucocorticoid treatment group and the non-frequent acute exacerbation with non-glucocorticoid treatment group (all P<0.05). The declines of FeNO value, blood eosinophil ratio and IL-8 level in the frequent acute exacerbation with glucocorticoid treatment group were also statistically significantly larger than those in the frequent acute exacerbations with non-glucocorticoid treatment group (all P<0.05). The improvement of CAT score in the frequent acute exacerbation with glucocorticoid treatment group was greater than that in other three groups (all P<0.05). There was no significant difference in CAT score between the non-frequent acute exacerbation with glucocorticoid treatment group and the non-frequent acute exacerbation with non-glucocorticoid treatment group (P>0.05).ConclusionsThe degree of airway inflammation is more obvious in patients with frequent acute exacerbation phenotype of COPD. FeNO value can reflect the level of airway inflammation in patients with frequent acute exacerbation of COPD and evaluate the response to glucocorticoid therapy.

    Release date:2020-11-24 05:41 Export PDF Favorites Scan
  • Diagnostic value of exhaled nitric oxide in adult asthma: a systemic review and meta-analysis

    ObjectiveTo explore the diagnostic value of fractional exhaled nitric oxide (FeNO) in adult asthma.MethodsPubMed, Embase, Cochrane Library, Wanfang, CNKI and VIP databases were searched for relevant literatures from the time of database establishment to February 2021. Data analysis were made by Revman and Stata.ResultsA total of 44 articles with 47 records and 9654 subjects were included. The diagnosis sensitivity, specificity, positive and negative predictive value of FeNO were 0.71 (95%CI 0.65 - 0.76), 0.80 (95%CI 0.75 - 0.84), 3.47 (95%CI 2.86 - 4.21), and 0.37 (95%CI 0.31 - 0.43), respectively. The diagnostic odds ratio was 9.49 (95%CI 7.13 - 12.61), and the area under the receiver operating characteristic curve was 0.82 (95%CI 0.79 - 0.85).ConclusionsFeNO has certain diagnostic value in diagnosis of asthma. Types of asthma, region and cut-off value all have impact on the diagnostic efficiency of FeNO.

    Release date:2021-07-27 10:29 Export PDF Favorites Scan
  • 呼出气一氧化氮检测在支气管哮喘中的应用

    【摘要】 呼出气一氧化氮(FeNO)作为一项无创、便捷的监测技术,能够测定气道炎症,特别对于重症哮喘不能行肺功能检测的患者,具有较高的临床可行性。其在支气管哮喘的诊断、评价严重程度、控制水平、指导用药和预测预后等方面有独特的临床价值,特别是FeNO在诊断支气管哮喘有较高的敏感性和特异性己基本达成共识,但各个研究设定的阈值不尽相同,还需要进一步研究;在评价哮喘的严重程度及控制水平方面价值是有限的;对指导用药的价值是临床争论最多的领域;预测(哮喘发作)预后,FeNO升高对预测哮喘患者病情发展均有所帮助,可使患者得到早期预防、治疗。但如何利用其更好的管理和监测哮喘还有待进一步探讨。

    Release date:2016-09-08 09:51 Export PDF Favorites Scan
  • Change of Nitric Oxide in the Exhaled Gas of Teenager Patients with Allergic Rhinitis Accompanied with Asthma Treated by Budesonide Formoterol Inhalant

    ObjectiveTo observe the effect of Budesonide formoterol inhalant on teenager patients with allergic rhinitis accompanied with asthma. MethodsForty-five teenager patients with allergic rhinitis accompanied with asthma treated between January 2012 and December 2013 were randomly divided into general treatment group, budesonide group and budesonide formoterol group, with 15 patients in each. Another 15 subjects undergoing physical examination were designated as the control group. Besides routine treatment, the budesonide group was also treated with budesonide inhalation at 100-200 μg twice a day, and the budesonide formoterol group was also treated with budesonide formoterol inhalation at 160 μg and 4.5 μg twice a day. The course of treatment lasted for four weeks. The patients were followed up for four weeks after the use of medicine halted. After treatment, exhaled nitric oxide (NO) examination were performed. ResultsThe amount of NO in the exhaled gas in all the three treatment groups were significantly different from the control group (P<0.05), and it was also significantly different between the Budesonide group and the budesonide formoterol group (P<0.05). ConclusionBudesonide formoterol inhalant has a good effect on teenager patients with allergic rhinitis accompanied with asthma in terms of improving exhaled NO.

    Release date: Export PDF Favorites Scan
  • The delayed diagnosis time of chronic obstructive pulmonary disease is associated with elevated type 2 inflammation markers.

    Objective To investigate the relationship between delayed diagnosis time (time from symptom onset to diagnosis) in patients with chronic obstructive pulmonary disease (COPD) and the burden of type 2 inflammation (defined as the persistent inflammatory status assessed by blood EOS counts, EOS%, and Fractional exhaled nitric oxide(FeNO) among other biomarkers).MethodsThis study was a single-center, observational study that included patients with COPD first diagnosis at the respiratory outpatient department of our hospital from June 2023 to December 2024. Asthma-COPD overlap (ACO) were identified according to the 2017 Spanish COPD guidelines. Clinical data were collected, including gender, age, delayed diagnosis time, acute exacerbations in the past year, pulmonary function tests, exhaled nitric oxide (FeNO), and type 2 inflammatory markers such as blood eosinophil counts (EOS). The correlation between the delayed diagnosis time and type 2 inflammation burden, as well as its influencing factors, were analyzed. Results A total of 195 patients were included, with 98 cases of COPD and 97 cases of ACO. The mean delayed diagnosis time was 18.0 (2.8, 37.5) months for the overall patients, 24.0 (1.0, 60.0) months for COPD, and 16.5 (3.0, 36.0) months for ACO, with no significant difference between the COPD and ACO groups (P>0.05). The median blood EOS counts, EOS%, andFeNO levels were 180 cells/μL, 1.9%, and 18 ppb in the COPD group, respectively, compared to 350 cells/μL, 4.7%, and 28 ppb in the ACO group, indicating higher type 2 inflammation levels in the ACO group (all P<0.001). A significant correlations were found between the disease course and the blood EOS counts and EOS% of the patients (respectively r=0.159, 0.152, all P<0.05).FeNO levels showed no significant correlation with delayed diagnosis time of COPD (P>0.05). Patients with a history of asthma and acute exacerbations in the past year had longer delayed diagnosis time and higher peripheral blood eosinophil counts (all P<0.05). Binary logistic regression analysis revealed that BMI and delayed diagnosis time were independent influencing factors for blood EOS counts (all P<0.05). ConclusionDelayed diagnosis of COPD was associated with aggravated type 2 inflammatory burden. Clinical practice should emphasize early recognition of COPD symptoms and implement prompt therapeutic interventions.

    Release date:2025-08-25 05:39 Export PDF Favorites Scan
  • The Clinical Features of Chronic Obstructive Pulmonary Disease according to Body Mass Index, Fractional Exhaled Nitric Oxide and Goddard Score

    Objective Chronic obstructive pulmonary disease( COPD) is highly heterogeneous. In theory, the patients with same clinical manifestations, treatment response and prognosis can be classified into one phenotype, which may have same biological or physiological mechanisms. In this study the profiles of patients with COPD including body mass index( BMI) , Goddard score, fractional exhaled nitric oxide( FeNO) were analyzed in order to find some special phenotypes.Methods Patients with COPD at stable stage in Ruijin Hospital from May 2011 to February 2012 were evaluated with COPD assessment test ( CAT) in Chinese version, St. George’s Respiratory Questionnaire( SGRQ) , hospital anxiety and depression( HAD) rating scale, pulmonary function test, and 6-minute walking test ( 6MWT) . Baseline data was collected including height, weight, drug use, times of exacerbation, etc. Results A total of 126 patients were recruited. The patients with low BMI had poorer quality of life, lower FEV1 , poorer diffusion function, and higher Goddard score, and was easier to develop anxiety and depression. The patients with high BMI had lower oxygen saturation at rest. We failed to define a certain kind of phenotype according to FeNO. The patients of emphysema phenotype( assessed by Goddard score) had lower BMI, decreased lung diffusion capacity, and poorer quality of life. Conclusion The study can define COPD patients into some special phenotypes( low BMI and emphysema phenotype) , but failed to define a certain kind of phenotype according to FeNO.

    Release date:2016-09-13 03:51 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content