west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Digit" 57 results
  • TRANSPLANTATION OF THE PALMARIS LONGUS TENDON WITH A VASCULAR PEDICLE FOR THE COMPLEX INJURY OF THE DIGITAL FLEXOR TENDON

    In order to seek a good method to treat the severe, complex damage of the digital flexor tendon, an anatomical study based on 30 cadavers was done, and the result showed that the source of the blood supply to the palmaris longus tendon was from the radial and ulnar arteries. Three cases of severe complex digital flexor tendon injuries were satisfactory. Its main advantages were: (1) The tendon transplant had its own blood supply and had no need to the revascularization, therefore the adhesion formed between the tendon and adjacent tisues might be less;(2) Besides reparing the tendon defect, it can simultaneously solve the problem of the defect of the soft tissues and the skin.

    Release date:2016-09-01 11:33 Export PDF Favorites Scan
  • Accuracy of computer-guided oral implant placement and influencing factors

    With the development of computer and digital technology, the application of computer-aided technology has become a new trend in the field of oral implant. Computer-guided oral implant surgery has the advantages of being safer and more accurate than traditional implant surgery, and it can truly realize the concept of restoration-oriented implant. However, computer-guided oral implant surgery has various steps which cause deviations accumulation, so that some clinicians remain sceptical about the accuracy of the technology. Currently, due to the lack of a quantitative system for evaluating the accuracy of computer-guided oral implantation, the implant deviation in each step is still inconclusively in the stage of research and debate. The purpose of this paper is to summarize the advantages and disadvantages, research progress, accuracy and influencing factors of computer-guided oral implantation, aiming to provide a reference for improving implant accuracy and guiding clinical design and surgery.

    Release date:2022-10-25 01:09 Export PDF Favorites Scan
  • Application progress and thinking of digital therapeutics in orthopedics

    In recent years, the rapid development of information and communication technology, big data, and artificial intelligence has provided technical support for exploring new medical methods, leading to the emergence of digital therapeutics (DTx). At present, the application of DTx in orthopedics is still in the preliminary exploration stage. Therefore, based on the authors’ experience of applying DTx, this article summarizes the definition and formation process of DTx, as well as the relationship among digital health, digital medicine, and DTx, evaluates the working principles and application effects of existing orthopedic related DTx products, analyzes their shortcomings in the application process, and looks forward to their future development trends, aiming to lay a foundation for the comprehensive development and application of DTx in orthopedics.

    Release date:2024-11-27 02:31 Export PDF Favorites Scan
  • Single-Injection Digital Block versus Traditional Digital Block for Local Anesthesia in Digital Injury Patients: A Randomized Controlled Trial

    Objective To compare the anesthetic effects of traditional digital block with single-injection digital block in digital injury patients for subcutaneous digital blocks. Methods Patients with one or two digits injured were randomized to the traditional digital block group and single-injection digital block group. All of the blocks were conducted by one investigator. The patients and outcome assessor were blinded to the treatment allocation. Both of the per-protocol-population (PP) analysis and the intention-to-treatment (ITT) analysis were performed to compare the two block techniques in terms of the pain during infiltration, the onset time of anesthesia and the failure rate of anesthesia. Results A total of 93 patients (109 digits) were included with 51 (61 digits) in the traditional block group and 42 (48 digits) in the single-injection block group.Two patients (3 digits) dropped out. Both of the PP analysis and ITT analysis showed that no significant difference between the two groups were detected in terms of the pain during infiltration, the onset time of anesthesia and the failure rate of anesthesia (P﹥0.05). Conclusions The subcutaneous single-injection digital block is as effective as the traditional digital block, but is much easier to perform. This technique is indicated for the digital anesthesia of palmar aspect distal to the proximal digital crease and dorsal aspect of the distal and middle phalanxes.

    Release date:2016-09-07 02:18 Export PDF Favorites Scan
  • Current situation of “digital divide” among the elderly under the background of intelligent medical treatment and countermeasures for aging adaptation

    With the rapid development of information science and technology, the development of internet medical service is irresistible, forming a new situation of digital ecological environment of medical cloud service. However, reform and innovation of medical service mode have brought many problems and challenges to the elderly with low level of information literacy and difficult operation of information and intelligent applications on mobile phones, forming a “digital gap” with intelligent medicine. This paper analyzes the status quo of the digital divide in the elderly group, and classifies the elderly according to the pain and difficulty of the elderly wisdom, and then implements a series of online and offline aging adaptation to build a harmonious and humanistic care Internet plus medical service ecosystem for the elderly. The project is closely related to the physical and psychological transformation of the elderly, and can be used for reference.

    Release date:2022-05-24 03:47 Export PDF Favorites Scan
  • Risk Factors for Carotid Stenosis in Patients with Ischemic Cerebrovascular Disease

    ObjectiveTo analysis the risk factors for carotid stenosis in patients with ischemic cerebrovascular disease based on digital subtraction angiography. MethodsA total of 312 patients diagnosed with ischemic cerebrovascular disease who underwent digital subtraction angiography from June 2011 to September 2013 were selected.The risk factors of carotid stenosis were analysised by multivariate logistic regression analysis. ResultsIn 312 patients,271 were with cerebral infarction and 41 were transient ischemic attack patients.There were 149 patients in carotid stenosis group (stenosis degree ≥50%) and 163 patients in control group (stenosis degree<50%).The age (OR=1.037,P=0.000) and coronary heart disease (OR=4.121,P=0.001) were independent risk factors of carotid stenosis with ischemic cerebrovascular disease. ConclusionCarotid stenosis is common in ischemic cerebrovascular disease.Age and coronary heart disease were the independent risk factors.The recognition and control of these risk factors are in favor of secondary prevention of ischemic cerebrovascular disease.

    Release date: Export PDF Favorites Scan
  • APPLICATION VALUE OF DIGITAL SUBTRACTION ANGIOGRAPHY IN REPAIR OF FOOT AND ANKLE WOUNDS WITH POSTERIOR TIBIAL ARTERIAL PERFORATOR FLAP

    ObjectiveTo explore the application value of digital subtraction angiography (DSA) in repairing foot and ankle wounds with posterior tibial arterial perforator flaps. MethodsBetween January 2010 and May 2014, 12 cases of foot and ankle wounds were repaired using posterior tibial arterial perforator flaps. There were 7 males and 5 females with an average age of 36 years (range, 22-54 years). The causes were machine injury in 2 cases, falling injury in 3 cases, and traffic accident injury in 7 cases. The disease duration ranged from 7 to 45 days (mean, 16 days). The size of wound ranged from 6 cm×4 cm to 10 cm×5 cm. Preoperative DSA was performed to observe the orientation and distribution of the posterior tibial arterial perforator and the relationship between perforator vessels. Correspondently, the flaps were designed and harvested. The size of flap ranged from 7 cm×5 cm to 11 cm×6 cm. The donor sites were repaired with skin grafts. ResultsPosterior tibial arterial perforator vessels send out ascending branches and descending branches while going down in the superficial layer. All branches were connected to form vertical chain-form anastamosis, and its orientation was consistent with limb vertical axis. According to DSA results, the flaps were designed and harvested easily. All flaps survived after operation. Meanwhile, wounds healed by first intention. All skin grafts at donor site survived. All patients were followed up 6 months. The flaps had good appearance, color, and texture. No ulcer was found. Affected feet had normal walking function. ConclusionThe size, distribution, and chain-form anastamosis condition of the posterior tibial arterial perforator vessels can be accurately observed by DSA, which provides imaging evidence for harvesting posterior tibial arterial perforator flaps and improves the success rate for repairing foot and ankle wounds.

    Release date: Export PDF Favorites Scan
  • Application of mixed reality technology in orthopedic field

    Mixed reality technology is new digital holographic imaging technology that generates three-dimensional simulation images through computers and anchors the virtual images to the real world. Compared with traditional imaging diagnosis and treatment methods, mixed reality technology is more conducive to the advantages of precision medicine, helps to promote the development of medical clinical application, teaching and scientific research in the field of orthopedics, and will further promote the progress of clinical orthopedics toward standardization, digitization and precision. This article briefly introduces the mixed reality technology, reviews its application in the perioperative period, teaching and diagnosis and treatment standardization and dataization in the field of orthopedics, and discusses its technical advantages, aiming to provide a reference for the better use of mixed reality technology in orthopedics.

    Release date:2021-09-24 01:23 Export PDF Favorites Scan
  • DECOMPRESSION AND DIVERTING EFFECTS OF VASCULAR ANASTOMOSIS BASED ON DIGITAL ARTERIAL ARCH BRANCH IN REPL ANTATION OF FREE FINGER-PULP

    ObjectiveTo investigate the decompression and diverting effects of vascular anastomosis based on the digital arterial arch branch in replantation of free finger-pulp in distal phalanges. MethodsA retrospective analysis was performed on the clinical data of 12 patients (12 fingers) who underwent free finger-pulp replantation with anastomosis of proper palmar digital artery and the palmar digital artery arch branch in the distal end between December 2004 and March 2015. Of 12 cases, 9 were male and 3 were female, aged 15-39 years with an average of 32 years. The causes of injury included cutting injury in 4 cases, crush injury in 7 cases, and avulsion injury in 1 case. The thumb was involved in 2 cases, index finger in 4 cases, ring finger in 3 cases, middle finger in 1 case, and little finger in 2 cases. The free finger pulp ranged from 1.8 cm×1.5 cm to 2.8 cm×2.0 cm. The time from injury to operation ranged from 1.5 to 11.0 hours, with an average of 5.7 hours. No arterial arch or proper palmar digital arteriae anastomosis was excluded. ResultsFree finger-pulp survived in 11 cases after operation; venous crisis occurred in 1 case at 2 days after operation, and was cured after symptomatic treatment. Nine cases were followed up 6-18 months with an average of 10 months. The finger-pulp had good appearance, clear fingerprint, and soft texture. The two-point discrimination was 3.1-6.0 mm, with an average of 4.6 mm at 6 months after operation. The function of finger flexion and extension was normal. And according to upper extremity functional evaluation standard by hand surgery branch of Chinese Medical Association, the results were excellent in 7 cases, and good in 2 cases. ConclusionIn the replantation of amputated pulp with insufficiency of venous blood outflow, the anastomosis of digital arterial arch branch in the distal end can decompress and shunt arterial blood, adjust blood inflow and outflow, and solve the problems of insufficient quantity of the vein and venous reflux disturbance.

    Release date: Export PDF Favorites Scan
  • Multidetector-Row CT Angiography and Digital Subtraction Angiography of Bronchial Artery in Diagnosis of Hemoptysis: A Comparative Study

    Objective To compare the bronchial arteriography through multidetector-row CT (MDCT) with the digital subtraction angiography (DSA) via femoral artery, and evaluate the application value of bronchial arteriography through MDCT in the diagnosis and treatment of hemoptysis. Methods 133 cases complained of hemoptysis were examined by MDCT and DSA via femoral artery respectively to perform bronchial arteriography, and the differences of image results by two methods were compared. Results 129 cases with abnormal bronchial arteries were confirmed by DSA via femoral artery, 117 cases were checked by MDCT [ the positive rate was 90.7% (117/129 ) ] . 117 cases with abnormal bronchial arteries were confirmed by both MDCT and DSA via femoral artery and 4 cases did not detected any abnormal arteries by both methods. The coincidence rate of two methods was 91.0% (121 /133) . MDCT and DSA via femoral artery showed the similar origins of abnormal bronchial arteries. The coincidence rate of two methods was 100% . Conclusions There is a high coincidence rate betweenMDCT and DSA in detecting bronchial artery abnormalities. MDCT shows the origins of abnormal vessels clearly which could be a fist-choice of routine imagination for interventive operation.

    Release date: Export PDF Favorites Scan
6 pages Previous 1 2 3 ... 6 Next