Objective To introduce the new progress of perforator flaps as an new reconstruction technique. Methods The literature both at home and abroad was reviewed, and the research findings of different perforator flaps were summarized. Results The advantage of perforator flaps versus musculocutaneous flaps was the reduced morbidity of the donor site with preservation of the nerves, muscles and deep fascia. The postoperative complications at donor sites reduced. Conclusion Perforator flap was the new and reliable technique forreconstructionof tissue defect and may be one of the primary choices in the future.
Objective To review the research progress in transplantation of the skeletal muscle myoblast. Methods The recentlypublished articles concernedwith the myoblast transplantation were reviewed, including myoblast culture, modified transplant methods, preparation of the recipient, scaffold choice, and aninfluence of the recipient’s immunity on the transplantation. How to improve the efficiency of the myoblast transplantation was also discussed. Results The techniques of the myoblast transplantation were improved and transplantation efficiency was increased. 〖WTHZ〗Conclusion The transplantation of the skeletal muscle myoblast has a great potential value in clinical practice and a promising future in its clinical application.
Objective To investigate the initiation of fracture repair and regulation on molecular level.Methods Literature concernedfracture repair and effects of correlative factors in the process in recent years was reviewed. The initiation in the process of fracture repair and the effects of the correlative factor were summarized to probe into effective methods to intervene. Results During fracture repair, the initiation had particular character and the correlative factors were concerned with the process. Conclusion The correlative factors regulate the initiation of fracture repair on molecular level.
Objective To choose suitable free flaps for reconstructing headand neck defects caused by tumor resection. Methods A retrospective analyses was made in 86 cases of head and neck defects treated with four kinds of free flaps between January 1999 and January 2002. The head and neck defects were caused by tumor resection. The locations were oral cavity (n=32), hypopharynx (n=27), mandible (n=12), skull base (n=5), scalp and skin (n=6) andmidface(n=4). The donor sites of free flaps included the rectus abdominis (n=32), anterolateral thigh (n=10),jejunum (n=25), fibula (n=11), latissimus dorsi (n=4), forearm (n=3) and scapula (n=1). The sizesof the cutaneous/musculocutaneous flaps ranged from 4 cm×5 cm to 14 cm×24 cm. The lengths of the fibula were 4-16 cm,of jejunum 9-20 cm. Results The overall free flap success rate was 92% (79/86). Of 32 oral cavity defects, 22 were reconstructed by rectus abdominis (69%) and 10 by anterolateral thigh flaps (31%). Of 27 hypopharyngeal defects, 25 were restored by jejunum flaps (93%). Eleven of 12 mandibular defects were reconstructed by fibula flaps(92%). Four of 5 defects of skull base were reconstructed by rectus abodominis flaps (80%). The free flaps of rectus abodominis, anterolateral thigh, jejunum and fibula were most frequently used, accounting for 91%(78/86) of all flaps in head and neck defect reconstruction. Conclusion Although head and neck defects represent a complicated spectrum of subsites and loss, these four freeflaps can manage most reconstruction problems.
【摘要】 目的 探讨重型颅脑损伤的死亡原因。方法 对2002年1月—2010年1月收治的54例重型颅脑损伤死亡患者,其受伤原因、受伤至入科时间、损伤时间、临床表现、治疗情况等临床资料进行回顾性分析。结果 原发或继发性颅脑损伤严重、严重的合并伤和术后并发症是死亡的重要因素。结论 重型颅脑损伤患者死亡的原因是多方面的,对此类患者须采取综合救治措施,以降低其死亡率。
Objective To compare the short-term effectiveness of repairing distal tibiofibular syndesmosis with metal screws and absorbable screws. Methods A retrospective analysis was performed on the clinical data of 63 patients with ankle fracture combined with injury of the distal tibiofibular syndesmosis admitted between January 2017 and January 2020. Among them, 31 patients were treated with absorbable screw fixation of the distal tibiofibular syndesmosis (research group) and 32 patients were treated with metal screw fixation of the distal tibiofibular syndesmosis (control group). There was no significant difference in gender, age, cause of injury, surgical side, time from injury to operation, fracture type, preoperative visual analogue scale (VAS) score, and American Orthopaedic Foot & Ankle Society (AOFAS) score between the two groups (P>0.05). The operation time and fracture healing time were recorded and compared between the two groups. X-ray film was taken to evaluate the effect of ankle joint reduction and fixation. Olerud-Molander ankle fracture efficacy score (short for OM score), AOFAS score, and VAS score were used to evaluate the effectiveness. Results There was no significant difference in operation time between the two groups (t=−0.683, P=0.497). In the control group, 1 case of delayed healing and 1 case of poor healing occurred in the lateral incision after operation, which healed after dressing change; the rest of the patients had primary healing of the incision. Patients in both groups were followed up 12-24 months, with an average of 13.8 months. In the control group, 1 patient with fracture of pronation and external rotation walked with full weight bearing after removing the metal screw of the distal tibiofibular syndesmosis at 8 weeks after operation, the anatomical plate of the lateral malleolus was broken, and the lateral malleolus was fixed again and recovered after 5 months; 1 patient had mild ankle pain after operation, and the pain disappeared after removing the metal screw of the distal tibiofibular syndesmosis at 8 weeks. No complication such as nerve and blood vessel injury occurred in all patients. There was no significant difference in fracture healing time between the two groups (t=−1.128, P=0.264). The AOFAS and VAS scores significantly improved in both groups at 12 months after operation (P<0.05). There was no significant difference between the two groups in the OM scores, and the difference of AOFAS and VAS scores between before and after operation (P>0.05). Conclusion Using absorbable screws to repair the distal tibiofibular syndesmosis can effectively restore the ankle acupoint structure, prevent ankle instability, and restore good ankle function. There is no significant difference in effectiveness between absorbable screws and metal screws, and there is no need for secondary operation to remove screws.
ObjectiveTo review the effect of obesity on the effectiveness of posterior lumbar fusion in patients with lumbar degenerative diseases (LDD).MethodsThe related literature at home and abroad was extensively reviewed. And the difficulty of operation, risk of complications, and long-term effectiveness of posterior lumbar fusion for obese patients with LDD were summarized.ResultsAlthough some relevant literature suggest that the posterior lumbar fusion for obese patients is difficult and the risk of postoperative complications is high, the overall research results do not suggest that obesity is a risk factor for the implementation of posterior lumbar fusion. By assessing the physical condition of patients and strictly grasping the surgical indications, obese patients can obtain good surgical efficacy.ConclusionPosterior lumbar fusion is an effective method for the treatment of LDD in obese patients. However, relevant studies need to be completed to further evaluate the safety and efficacy of posterior lumbar fusion for obese patients.
ObjectiveTo review and evaluate the technical advantages and disadvantages and research progress of percutaneous endoscopic lumbar interbody fusion. MethodsThe domestic and foreign related research literature on percutaneous endoscopic lumbar interbody fusion was extensively consulted. The advantages, disadvantages, and effectiveness were summarized. And the development trend of this technology was prospected. ResultsCompared with minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF), percutaneous endoscopic lumbar interbody fusion has less intraoperative and postoperative bleeding, better improvement of low back pain in the early stage after operation, and similar long-term effectiveness, fusion rate, and incidence of complication, but a longer learning curve. The operation time of biportal and large-channel uniportal endoscopic lumbar fusion is close to that of MIS-TLIF, but the operation time of small-channel uniportal endoscopic fusion is longer than that of MIS-TLIF. ConclusionPercutaneous endoscopic lumbar interbody fusion has the advantages of less trauma and good effectiveness, but its learning curve is long, and indications should be strictly selected for this operation. In the future, with the continuous development and complementation of various endoscopic fusion technologies, this technology will gain better application prospects.
To accurately capture and effectively integrate the spatiotemporal features of electroencephalogram (EEG) signals for the purpose of improving the accuracy of EEG-based emotion recognition, this paper proposes a new method combining independent component analysis-recurrence plot with an improved EfficientNet version 2 (EfficientNetV2). First, independent component analysis is used to extract independent components containing spatial information from key channels of the EEG signals. These components are then converted into two-dimensional images using recurrence plot to better extract emotional features from the temporal information. Finally, the two-dimensional images are input into an improved EfficientNetV2, which incorporates a global attention mechanism and a triplet attention mechanism, and the emotion classification is output by the fully connected layer. To validate the effectiveness of the proposed method, this study conducts comparative experiments, channel selection experiments and ablation experiments based on the Shanghai Jiao Tong University Emotion Electroencephalogram Dataset (SEED). The results demonstrate that the average recognition accuracy of our method is 96.77%, which is significantly superior to existing methods, offering a novel perspective for research on EEG-based emotion recognition.
Objective To discuss the stabil ity and practical ity of temporomandibular joint replacement by establ ishing goats artificial temporomandibular joint replacement model. Methods Six healthy mature goats were selected, the male and female being half and weighing 35.3-37.0 kg. According to the parameters from X-ray films of goat’ s temporomandibular joint and the shape of the same kind goat’s skull, the total temporomandibular joint prosthesis was prepared. The one side temporomandibular joints of six goats were replaced by prosthesis randomly as the experimental group (n=6, fossa and condyle according to replacement location) and the other side by titanium plate as the control group (n=6). At 4,8, and 12 weeks, the histological observation, scanning electron microscope (SEM) observation were carried out for observing structural changes in the interface. The mechanical test and histochemistry test were used for observing the combination degree of interface and the alkal ine phosphatase (ALP) activity. Results All animals were al ive to the end of experiment with normal open mouth, good recovery of masticatory function, and normal eating. At 4, 8, and 12 weeks, implants were stable in 2 groups without loosening. The histological observation and SEM observation showed the amount of osteoblasts in interface increased over times. There were significant differences in the shearing force and the ALP activity between fossa in experimental group and control group at 4 weeks (P lt; 0.05), but there was no significant difference between other groups (P gt; 0.05). Conclusion The total temporomandibular prosthesis has good stabil ity in temporomandibular joint reconstruction of goat after replacement.